Queenaire QT Thunder-24 QTT24-II Handleiding
Queenaire
Luchtreiniger
QT Thunder-24 QTT24-II
Lees hieronder de 📖 handleiding in het Nederlandse voor Queenaire QT Thunder-24 QTT24-II (2 pagina's) in de categorie Luchtreiniger. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
QUEENAIRE TECHNOLOGIES, INC.
“The Ozone Specialists”
Queenaire Technologies, Inc.
P.O. Box 133
Ashburn, VA 20146
Toll Free: 1-877-64 OZONE
Tel: 1-703-654-0385 Fax: 1-703-654-0386
Volume
1
Owners Manual
QT Thunder-24
How Does QT Thunder-24 Eliminate Odors?
All Queenaire Technologies, Inc. units eliminate odors by producing a controlled level of ozone. Ozone is
created naturally in our environment by lightning and the suns ultraviolet rays. It is best known for its benefit in
the stratosphere for protecting us from the suns rays. What you may not know is that it is also that fresh smell
you experience after a lightning storm. Ozone is Mother Nature’s solution to outdoor odor problems. QT
Thunder-24 incorporates a technology that duplicates the effect of lightning and creates ozone indoors. The end
result is the same, a fresh, odor free environment.
QT Thunder-24 Maintenance Instructions
The life expectancy of your QT Thunder-24 unit is 10 - 15 years, provided it is serviced and maintained on a
regular basis. It is recommended that you perform a simple cleaning and maintenance of your unit every 6
months. Maintenance kits are available through your distributor.
Before you begin performing any work to your ozone unit, be sure to unplug the electrical cord.
Step 1.) Remove two screws on the top of the unit as well as the top two screws on each side of the unit.
Remove the top cover from the unit.
Step 2.) Carefully remove the white ceramic generator plate from its frame. The plate should lift easily by
pulling from the top straight up and out of the frame. Use an alcohol wipe to gently wipe the plate free of any
dirt or stains. Inspect the plate carefully for cracks, breaks or irremovable stains. The plate can be reused
provided there are no breaks or stains.
Step 3.) Use the same alcohol wipe to wipe out the exposed areas inside the unit. Spread the generator frame
apart to wipe the inside of the metal plates that make contact with the generator plate. Be sure to also wipe the
base of the frame completely.
Step 4.) Once the ceramic plate is completely dry, reinsert the plate into the generator frame or replace the
existing plate.
Step 5.) Reattach the top cover to the unit and put screws back in place.
Step 6.) Remove and discard the green filter on the back of the machine and replace with new filter.
Step 7.) You may at this point have to change your 125mA fuse. To test your fuse, simply turn the unit on. If
the green ozone light comes on you have completed maintenance of the unit and are ready to put it back in
service. If the light does not come on, locate the 125mA fuse holder on the back of the unit and remove the
holder with a flat head screwdriver by turning the holder 1/4 turn. Remove the blown fuse and replace the fuse.
Your unit should now be ready to go back to work.
Trouble Shooting Guide
If you are having problems with your ozone machine please refer to the following instructions:
1. The fan comes on, but the green light does not. Remove the top cabinet from
the unit and check the condition of the ceramic plate. Replace if broken.
Replace top cabinet. Remove and replace the .125 milliamp fuse in the back of
the unit. If the green indicator light is still out contact your distributor.
2. When you turn the unit on nothing happens. First check your power source to
ensure there is power to the outlet. Plug the unit in. Check the fuse marked 2
amp on the back of the unit. Replace with spare if blown. If the unit still does
not operate contact your distributor.
3. There is no display on the face of the timer. The 1.5 VOLT battery should operate your timer for 3 years or
more under typical conditions. High or low temperature or frequent use of the manual pushbutton will reduce
the battery life. Replace the battery when the digital display is dim, the message “lobAt” (Meaning LOW
BATTERY) is displayed, or if the timer fails to operate. Press any button to clear the “lobAt” message. The
timer has built-in memory protection providing at least 15 seconds to change a week battery without losing your
settings.
4. If for any reason you are not happy with the performance of this unit contact customer service at 1-877-64
OZONE.
T
Operating QT Thunder-24
Following are basic instructions for programming your unit to eliminate odors in an area up to 10,000 cubic
feet when the treated area is unoccupied.
his unit features a programmable timer with up to 6 On/Off setting pairs (12 automatic switch settings).
Each setting time can be once a week, every day, every weekday, or only on weekends. The timed
settings combined with a fixed ozone output of 300 mg/hr, allows the user the ability to effectively
deodorize a given area up to 10,000 cu/ft on a scheduled basis when the area is vacant. A manual
override option gives you ozone on demand for a quick clean up.
Determine your Programmed Settings
The time needed to effectively eliminate odors in a given area depends greatly on the size of the room, the level of
odor in the room, temperature and humidity. Our recommendation is that you run the unit for 30 minutes for every
2400 cu/ft of space being treated. You should adjust the unit for shorter run times if you detect an ozone odor after
the unit has been off for a time equal to the time it was in operation. If the odor is still present after the unit has ran
you should adjust the unit to run for longer periods. After the first week of treatment you may have to adjust the
unit to shorter run times as the odor factor should be significantly lower. In the summer months, you may have to
adjust the unit to run for longer intervals, as the humidity levels will decrease ozone output. You should always
allow ample time for ozone levels to dissipate before occupying a treated area. Usually an amount of time equal to
the time the unit was in operation is sufficient. If you need help in determining your programmed settings, please
contact Customer Service at 1-877-64 OZONE.
While smell is not an accurate guide to ozone levels, in levels above .03 ppm ozone has a very strong unpleasant
odor. If you are experiencing a strong odor, headache, dry nose and/or dry throat, you should adjust the run time
for shorter periods or allow a longer period of time before occupying the area to allow the levels to dissipate.
Programming The Timer
The timer used in this unit is basically a programmable switch. At any time you can push the clear cover/switch to
manually turn the unit ON or OFF, unless selected mode is CLK or PGM. You can program up to 12 ON/OFF
events; times when the timer automatically switches the unit ON or OFF (up to 6 ON events and 6 OFF events). An
event can be set to switch at:
☛ any specific time, and day of the week
☛ a specific time every day
☛ a specic time on weekends, or
☛ a specific time on weekends
Controls & Displays
Manual Override Works like a light switch. Push and release
the clear cover/switch to switch ON and OFF.
o Works in AUTO, AUTO RAND, or MAN modes.
o You hear a motor clicking sound.
o ON/OFF display changes.
o The program in AUTO or AUTO RAND remains:
it automatically switches ON or OFF at next
programmed time.
Push On/Off
Cover/Switch
The clear cover/switch is the manual ON/OFF control.
1. Pull at notch at top edge to remove cover so you can use the programming buttons.
To replace cover /switch:
2. Set bottom in first
3. Click in the top
To remove battery:
4. Grasp holder at side bumps (4a, 4b)
and pull straight out.
To re-install battery:
5. Replace battery in holder with “+” end towards front of timer. Insert battery and holder into timer.
Push at (5) so it clicks into place
Battery Holder
Push Buttons: RESET Button
Recessed so you don’t push it accidentally. Push and release to reset: When you press RESET:
• The mode switched to MAN.
• The switch is set to on.
• The clock is set to MO 12:00 AM and ashes
• All programmed ON or OFF times are set to null (at null, no switching occurs, clock
displays -:—). (after pushing RESET, you must see the clock then set the ON/OFF times.)
• If NoOp appears in display, push battery cover in until you hear a click. Push reset
button to clear display. Proceed with programming.
MODE Button
Push and release to change the mode (upper line of the display).
CLK mode - To set or change the time.
PGM mode - To set, review or change programmed ON/OFF times.
AUTO mode - Programmed ON/OFF times work. Manual switching works.
AUTO RAND mode - Programmed ON/OFF times work and are randomly oset up to 15
minutes. Manual switching works.
MAN mode - Only manual switching works. Programmed ON/OFF times remain in memory.
The Mode button skips the AUTO modes if the time of day and or the ON/OFF times have not
been set.
DAY Button
Function depends on the mode.
CLK mode - Push and release to cycle through the days of the Week:
MO,TU,WE,TH,FR,SA,SU. Push to hold and cycle quickly.
PGM mode - Push and release to cycle through all week, weekdays, weekend, individual days
of the week and null: MO TU WE TH FR SA SU (all displayed at once is all week)
MO TU WE TH FR (all displayed at once is weekdays) SA SU (displayed is weekend)
MO TU WE TH FR SA and SU (are individual days)
-:— (on clock display is the null setting)
Use null to cancel an unwanted ON or OFF setting. The Day button does nothing in AUTO,
AUTO RAND or MAN modes.
H+ (hour) Button
Works in CLK and PGM modes
Push and release to cycle forward through the hours of the day.
Push and hold to cycle quickly.
AM and PM automatically switch at 12.
If you pass the correct hour, push and hold to cycle around again.
M+ (minute) Button
Works in CLK and PGM modes
Push and release to cycle forward through the minutes.
Push and hold to cycle quickly.
AM and PM automatically switch at 12.
If you pass the correct minute, push and hold to cycle around again.
ON/OFF/EVENT Button
Function depends on the mode.
CLK mode - ON/OFF EVENT button does nothing.
PGM mode - Switches in order through the 12 programmable Events 1 ON, 1 OFF, 2 ON, 2
OFF, 3 ON, 3 OFF,4 ON, 4 OFF, 5 ON, 5 OFF, 6 ON, 6 OFF.
AUTO mode- Manually turns switch on or o.
AUTO RAND mode - Manually turns switch on or o.
MAN mode- Manually turns switch on or o.
How to set or change the clock
1. Remove the clear cover/switch.
2. Push and release MODE button until CLK is
displayed (2a).
3. Push and release DAY button until correct day of
week is displayed (3a.)
4. Push and release H+ button until hour and AM/
PM are correct (4a).
5. Push and release M+ button until minutes are
correct (5a)
6. Push and release
MODE button to chose
AUTO, AUTO RAND
or MAN
7. Replace cover/
switch.
8. Push and release
clear cover/switch to
switch load ON or OFF
if necessary.
How to set, change, or review ON/OFF times
1. Remove the clear cover/switch.
2. Push and release MODE button until PGM is displayed (2a) at event (1 on)
3. If necessary, push and release ON/OFF/EVENT button until event to set/change
is displayed (3a), or push the ON/OFF/Event pushbutton repeatedly to review all the
ON/OFF times.
4. Push and release DAY button until desired day or group of days is
displayed (4a), or push and release the
DAY button until -:— is displayed, if
you would like to cancel this ON or OFF
time.
5. Push and release H+ button until
desired event hour and AM/PM are
displayed (5a).
6. Push and release M+ button until
desired minutes are displayed (6a)
7. Push and release ON/OFF/EVENT
button to choose the next event to set
or change (7a)
8. Push and release MODE button to
choose AUTO, AUTO RAND, or
MAN.
9. Replace cover/switch.
10. Push and release clear cover/
switch to switch load ON or OFF if
necessary.
Product specificaties
Merk: | Queenaire |
Categorie: | Luchtreiniger |
Model: | QT Thunder-24 QTT24-II |
Heb je hulp nodig?
Als je hulp nodig hebt met Queenaire QT Thunder-24 QTT24-II stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Luchtreiniger Queenaire
6 Juni 2023
25 Mei 2023
12 Mei 2023
11 Mei 2023
5 Mei 2023
Handleiding Luchtreiniger
- Luchtreiniger Electrolux
- Luchtreiniger Braun
- Luchtreiniger Bosch
- Luchtreiniger Philips
- Luchtreiniger IKEA
- Luchtreiniger Samsung
- Luchtreiniger Delonghi
- Luchtreiniger Xiaomi
- Luchtreiniger Panasonic
- Luchtreiniger LG
- Luchtreiniger AEG
- Luchtreiniger BEKO
- Luchtreiniger Fysic
- Luchtreiniger Honeywell
- Luchtreiniger JVC
- Luchtreiniger Karcher
- Luchtreiniger Miele
- Luchtreiniger Motorola
- Luchtreiniger Medion
- Luchtreiniger Quigg
- Luchtreiniger Tefal
- Luchtreiniger Topcom
- Luchtreiniger Toshiba
- Luchtreiniger Unold
- Luchtreiniger Whirlpool
- Luchtreiniger Hoover
- Luchtreiniger Acer
- Luchtreiniger Adler
- Luchtreiniger Aeris
- Luchtreiniger Air-O-Swiss
- Luchtreiniger Airbutler
- Luchtreiniger Airfree
- Luchtreiniger Alpina
- Luchtreiniger Aluratek
- Luchtreiniger Amprobe
- Luchtreiniger Andrews
- Luchtreiniger Argo
- Luchtreiniger Bartscher
- Luchtreiniger Be Cool
- Luchtreiniger Bestron
- Luchtreiniger Beurer
- Luchtreiniger Bionaire
- Luchtreiniger Bissell
- Luchtreiniger Blaupunkt
- Luchtreiniger Blue Air
- Luchtreiniger Bob Home
- Luchtreiniger Boneco
- Luchtreiniger Bort
- Luchtreiniger Breville
- Luchtreiniger Daikin
- Luchtreiniger Daitsu
- Luchtreiniger Dimplex
- Luchtreiniger Dirt Devil
- Luchtreiniger Domo
- Luchtreiniger Duracraft
- Luchtreiniger Duux
- Luchtreiniger Dyson
- Luchtreiniger Easy Home
- Luchtreiniger Efbe-schott
- Luchtreiniger Elro
- Luchtreiniger Emerio
- Luchtreiniger ETA
- Luchtreiniger Eurom
- Luchtreiniger Evolar
- Luchtreiniger Ezviz
- Luchtreiniger Fakir
- Luchtreiniger Falmec
- Luchtreiniger Fellowes
- Luchtreiniger Fuave
- Luchtreiniger Galanz
- Luchtreiniger Gastroback
- Luchtreiniger GE
- Luchtreiniger Gemini
- Luchtreiniger Gorenje
- Luchtreiniger Gutfels
- Luchtreiniger H.Koenig
- Luchtreiniger Habitat
- Luchtreiniger Haier
- Luchtreiniger Hansa
- Luchtreiniger Hanseatic
- Luchtreiniger Haus Luft
- Luchtreiniger Health-Mor
- Luchtreiniger Helios
- Luchtreiniger Hisense
- Luchtreiniger Hitachi
- Luchtreiniger Homedics
- Luchtreiniger Hunter
- Luchtreiniger Ideal
- Luchtreiniger Innoliving
- Luchtreiniger Instant Pot
- Luchtreiniger IonizAir
- Luchtreiniger IQAir
- Luchtreiniger Kalorik
- Luchtreiniger Klarbach
- Luchtreiniger Klarstein
- Luchtreiniger Kodak
- Luchtreiniger Kogan
- Luchtreiniger Lanaform
- Luchtreiniger Laserliner
- Luchtreiniger Leifheit
- Luchtreiniger Leitz
- Luchtreiniger Lentz
- Luchtreiniger Lifeair
- Luchtreiniger Livoo
- Luchtreiniger Maxwell
- Luchtreiniger Maxxmee
- Luchtreiniger Meaco
- Luchtreiniger Medisana
- Luchtreiniger Mill
- Luchtreiniger Mitsubishi
- Luchtreiniger Moneual
- Luchtreiniger Nedis
- Luchtreiniger Periso
- Luchtreiniger Philco
- Luchtreiniger Polti
- Luchtreiniger Prem-i-air
- Luchtreiniger Profile
- Luchtreiniger Qlima
- Luchtreiniger Qlima - Zibro
- Luchtreiniger Reer
- Luchtreiniger REMKO
- Luchtreiniger Rowenta
- Luchtreiniger Royal Sovereign
- Luchtreiniger Russell Hobbs
- Luchtreiniger Sanyo
- Luchtreiniger Sauber
- Luchtreiniger Sencor
- Luchtreiniger Shark
- Luchtreiniger Sharp
- Luchtreiniger Silvercrest
- Luchtreiniger Soehnle
- Luchtreiniger Solis
- Luchtreiniger Sonnenkonig
- Luchtreiniger SPT
- Luchtreiniger Stadler Form
- Luchtreiniger Steba
- Luchtreiniger Stirling
- Luchtreiniger Stylies
- Luchtreiniger Sunbeam
- Luchtreiniger Suntec
- Luchtreiniger Sygonix
- Luchtreiniger Taurus
- Luchtreiniger TCL
- Luchtreiniger Teco
- Luchtreiniger Tesla
- Luchtreiniger Tosot
- Luchtreiniger Tristar
- Luchtreiniger Trotec
- Luchtreiniger Turmix
- Luchtreiniger Ufesa
- Luchtreiniger Uni-T
- Luchtreiniger VAX
- Luchtreiniger Venta
- Luchtreiniger Vicks
- Luchtreiniger Vornado
- Luchtreiniger WDH
- Luchtreiniger Whynter
- Luchtreiniger Winix
- Luchtreiniger Woods
- Luchtreiniger Zelmer
- Luchtreiniger Zepter
- Luchtreiniger Olimpia Splendid
- Luchtreiniger OneConcept
- Luchtreiniger Oregon Scientific
- Luchtreiniger Valore
- Luchtreiniger Black And Decker
- Luchtreiniger Concept
- Luchtreiniger Cuisinart
- Luchtreiniger ECG
- Luchtreiniger Guzzanti
- Luchtreiniger Hamilton Beach
- Luchtreiniger Heinner
- Luchtreiniger OBH Nordica
- Luchtreiniger Orbegozo
- Luchtreiniger Scarlett
- Luchtreiniger Trisa
- Luchtreiniger Wilfa
- Luchtreiniger Steren
- Luchtreiniger Soler And Palau
- Luchtreiniger Instant
- Luchtreiniger Hilti
- Luchtreiniger Danby
- Luchtreiniger EMOS
- Luchtreiniger Infiniton
- Luchtreiniger Cotech
- Luchtreiniger Ardes
- Luchtreiniger Eldom
- Luchtreiniger GOTIE
- Luchtreiniger Teesa
- Luchtreiniger Alen
- Luchtreiniger ElectriQ
- Luchtreiniger Heaven Fresh
- Luchtreiniger Heylo
- Luchtreiniger Holmes
- Luchtreiniger Inventor
- Luchtreiniger Oreck
- Luchtreiniger Prime3
- Luchtreiniger Proficare
- Luchtreiniger TruSense
- Luchtreiniger Brondell
- Luchtreiniger Brentwood
- Luchtreiniger Lenoxx
- Luchtreiniger Oricom
- Luchtreiniger Bimar
- Luchtreiniger Crane
- Luchtreiniger Lasko
- Luchtreiniger Rikon
- Luchtreiniger SPC
- Luchtreiniger Cecotec
- Luchtreiniger Thermex
- Luchtreiniger Carrier
- Luchtreiniger SHE
- Luchtreiniger Perfect Aire
- Luchtreiniger LTC
- Luchtreiniger Hombli
- Luchtreiniger Levoit
- Luchtreiniger Aerial
- Luchtreiniger Blueair
- Luchtreiniger Argoclima
- Luchtreiniger Clean Air Optima
- Luchtreiniger AENO
- Luchtreiniger Cado
- Luchtreiniger Łucznik
- Luchtreiniger Beghelli
- Luchtreiniger Ulsonix
- Luchtreiniger Uniprodo
- Luchtreiniger GermGuardian
- Luchtreiniger MSR
- Luchtreiniger LightAir
- Luchtreiniger Coway
- Luchtreiniger XPower
- Luchtreiniger Sensede
- Luchtreiniger Airthereal
- Luchtreiniger PURIFY
- Luchtreiniger Therapure
- Luchtreiniger AirExchange
- Luchtreiniger Djive
- Luchtreiniger TruSens
- Luchtreiniger Newaire
- Luchtreiniger Ametista
- Luchtreiniger Dri Eaz
- Luchtreiniger NEO Tools
- Luchtreiniger Jarden
- Luchtreiniger JIMMY
- Luchtreiniger Sôlt
- Luchtreiniger Pingi
- Luchtreiniger Ravanson
- Luchtreiniger E.ziclean
- Luchtreiniger Zedar
- Luchtreiniger Nevoox
- Luchtreiniger AlorAir
- Luchtreiniger Camfil
- Luchtreiniger Kleva
- Luchtreiniger House & Luft
- Luchtreiniger AeraMax
- Luchtreiniger Guardian
- Luchtreiniger Envion
- Luchtreiniger RainbowAir
- Luchtreiniger Haus & Luft
- Luchtreiniger ASIGO
- Luchtreiniger P3 International
- Luchtreiniger Luma Comfort
- Luchtreiniger Ionmax
- Luchtreiniger Greentec
- Luchtreiniger Airo
- Luchtreiniger Meross
- Luchtreiniger MANN+HUMMEL
- Luchtreiniger Airocide
- Luchtreiniger PRIMAVERA
- Luchtreiniger OZONOS
- Luchtreiniger Welcare
- Luchtreiniger Coplax
- Luchtreiniger DH Lifelabs
- Luchtreiniger Hacienda
- Luchtreiniger FilterStream
- Luchtreiniger Aconatic
- Luchtreiniger Arovec
- Luchtreiniger Imarflex
Nieuwste handleidingen voor Luchtreiniger
14 September 2024
14 December 2024
10 December 2024
8 December 2024
8 December 2024
8 December 2024
8 December 2024
4 December 2024
1 December 2024
1 December 2024