HOB MOUNT SENSOR TAP
VE402CR/VE402MB
CARE & MAINTENANCE
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning. Under No Circumstances
should abrasive or acid based cleaning products be used
WARRANTY
This warranty does not cover against normal wear and will be voided if the product is misused or
not installed in accordance with these instructions.
In the event this product is rendered obsolete and a replacement product is required, Oliveri Solutions Pty Ltd
reserves the right to supply a product of equal substitution at their discretion.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur, immediately shut off the water
supply. If the tap requires servicing, please contact your plumber (preferably the one who installed
it). Most problems occur due to contaminated supply lines or water pressure exceeding 500KPa.
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water pressure.
If the Plumber is satisï¬ed that the problem is not due to poor installation, contact T2 Services Pty Ltd for
assistance on:
Ph: (07) 5596 0738
Fax: (07) 5527 3353
Email: https: //oliveri.com.au/service-and-warranty
If a warranty service agent ï¬nds that the tap is not at fault, T2 Services Pty Ltd reserves the right to
pass on any callout fee to the householder.
THIS SENSOR TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS
This Oliveri sensor tap is manufactured to standard AS/NZS 3718.
Technical Data
Installation Instructions
VE402CR/VE402MB installation instructions.pdfIssue Date 08/08/2020 Revision Number: V1.0
MAX OPERATING PRESSURE.............................................................5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE........................................1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE .....................................................55°C
RECOMMENDED HOT WATER TEMPERATURE.................................50°C
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure
Before attempting any work involving mains water supply lines, ensure the water supply is shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri tap to allow isolation.
Failure to do so where required will void warranty.
This sensor tap must be installed in accordance with these instructions.
Oliveri warrant that the sensor tap will be leak-free and drip-free for 5 years under normal use, and the Productâs
control box (which houses the hydraulic system) and finish will be free from defects in material and
manufacturing workmanship (but only so long as the Original Consumer/Commercial Purchaser continues to own
the dwelling or premises).
The warranty on all other components of the Product, including but not limited to the electronics box, spout and
lenses, runs for: (1) five years from the date of purchase for an Original Purchaser; or (2) one year from date of
purchase for an Original Commercial Purchaser (but only so long as the Original Consumer/Commercial
Purchaser continues to own the dwelling or premises).


VE402CR/VE402MB installation instructions.pdf
Installation Instructions
Issue Date 08/08/2020 Revision Number: V1.0
Installation Instructions
General Note:
This product is to be installed by a licensed plumber,installation must comply with
AS/NZS 3500 and local plumbing codes
Pressures & Temperatures
Maximum Hydrostatic Pressure â 500 kpa. (As per AS/NZS3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that âProvision shall be made to ensure that the
maximum static pressure at any outlet, other than a fire service outlet, within a building does not
exceed 500 kPa.
Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances,
taps and fittings, and cause excessive noise in the system.
Minimum Hydrostatic Pressure â 100 kpa
The Maximum operating temperature for the Senser Tap is 55â.
Please ensure that the lines are flushed prior to installation as contaminates in the water can damage the
flow regulator and also affect the performance of the Sensor.
To the consumer
1. The tap is to only be cleaned with warm soapy water and a soft cloth.
2. Under No Circumstances should any abrasive, cream or acid based cleaning agents be used as these
types of cleaners will damage the chrome finish, Cartridge, seals and aerators.
spout
water inlet hose
control box
water outlet hose
signal cable
socket
power
adaptor
socket
reset
button
signal cable
1.
screw nut
rubber washer Safety- DO NOT connect unit to mains power or turn on mains water supply until Sensor tap and control unit is fully installed.
1. Remove product from packaging and check for damages, if the product is damaged do not install and return to store of purchase.
2. The WELS compliant aerator has been pre-assembled into the tap outlet. To comply with WELS the flow regulator must remain in
place.
3. Ensure product is complete as per exploded drawing.
4. A single 35mm hole is required in the mounting surface.
5. Remove Lock nut and thick rubber sealing washer from spout.
6. Put the Inlet hose and signal cable through the mounting hole ensuring thin bench sealing washer is in place on the base of the spout.
7. Assemble thick washer and lock nut to spout and tighten
N.B Spout thread has two flats to allow for spanner engagement to hold spout in place while tightening lock nut.
8. Position Control box on wall considering length of Spout outlet hose and signal cable.
Control unit must be within 500mm from Basin, refer to Diagram (5) & (6) for correct positioning of control box.
Using wall toggles supplied or suitable wall toggles and screw to suite wall material fit control box to wall.
Ensure control unit is fixed to a vertical wall in a position away from moisture and is always kept dry.
N.B Control box must be installed with inlet thread to Right, outlet thread to the bottom on a vertical wall, do not assemble in a horizonal
position. Diagram (1, 5, 6)
9. Fit spout outlet hose to control box outlet 1/2" BSP thread. Diagram (2)
10. Fit Spout Signal cable socket to control box socket. Align ends, push together and tighten socket nut by hand. Diagram (3)
11. Connect Inlet Water supply to 1/2"BSP thread on the control box inlet, (right hand side of control box) turn water supply on and check
for leaks at all connections. Diagram (4)
N.B Stop valves (preferably with filters) must be used when installing your Oliveri Tap to allow isolation.
AC Mains Power only
12. Connect control box power socket to AC power adaptor. Diagram (7)
N.B If using batteries only push control box socket into rubber protection boot on left side of control box to protect terminal ends.
DC Battery Power only
13. Remove the four screws holding the face plate on the Control box.
Unplug the AA battery box from the control box, remove single screw holding cover on battery box. Fit four AA batteries in battery box as
shown in battery box diagram.
Reverse process to fit battery box back into control box. Diagram (8)
14. Wipe down spout and sensor window situated at the end of the spout. Diagram (9)
15. Turn power on if connected to AC power.
16. Hold Red reset button located on the left-hand side of the control box in for 2 seconds to enable sensor to learn the IR distance to the
basin. Diagram (10)
Product specificaties
Merk: | Oliveri |
Categorie: | sensor |
Model: | VE402CR |
Heb je hulp nodig?
Als je hulp nodig hebt met Oliveri VE402CR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding sensor Oliveri

3 April 2025
Handleiding sensor
- sensor Panasonic
- sensor Hikvision
- sensor Jung
- sensor Festo
- sensor Carrier
- sensor IFM
- sensor Crestron
- sensor Moen
- sensor Metz Connect
- sensor Chauvin Arnoux
- sensor Sensirion
Nieuwste handleidingen voor sensor

31 Maart 2025

31 Maart 2025

31 Maart 2025

4 Februari 2025

30 Januari 2025

18 December 2024

18 December 2024

18 December 2024

18 December 2024

18 December 2024