Thermistor, Immersion
Installation and Operation
#NSA-A/CP-I-2.5- NSA-A/CP-I-4- NSA-A/CP-I-6-4X, 4X, 4X, NSA-HH/CP-I-2.5- -C NSA-HH/CP-I-4- -C PB , PB
NSA-HH/CP-I-6- -C /15/2019 PB –11
Specications subject to change without notice.
Catalog No. - - - Page of 11 808 785 01 1 5
Overview
Carrier Immersion Thermistors provide a predictable and accurate output over the specied
temperature range. Each sensor configuration is designed and manufactured for long-term
quality and performance. Carrier incorporates standard features such as double encapsulation
and etched Teflon leads where applicable.
Part Numbers
NSA-A/CP-I- - NSA-A/CP-I-4- NSA-A/CP-I-6- NSA-HH/CP-I-2.5- -C 2.5 4X 4X 4X PB
NSA-HH/CP-I-4- -C A-HH/CP-I-6- -C PB NS PB
Specications
Number Sensing Points:
One
Storage Temperature Range:
-40 to 85 °C (-40 to 185 °F)
Operating Humidity Range:
0 to 90% RH, non-condensing
Probe Diameter | Thermowell Bore Diameter:
0.250” (6.35mm) | 0.260”
Probe Material | Thermowell Material:
304 Stainless Steel | 304 Series Stainless Steel
Wire Size
22 AWG (0.65 mm)
Thermowell Instrument | Process Thread Size:
½” NPS (National Pipe Straight) Female Thread | ½” NPT (National Pipe
Tapered) Male Thread
Enclosure Specications
(Temperature, Material,
Flammability, NEMA/IP Ratings)
“ PB” Enclosure-: ABS Plastic, UL94-HB, -30 to 90 °C (-22 to 194 °F),
Plenum Rated
“ 4X” Enclosure-: Polystyrene Plastic, UL94-V2, -40 to 70°C (-40 to 158°F),
NEMA 4X (IP 66)
Sensor Output @ 25 °C (77 °F):
(Lead Wire Colors)
10 KΩ nominal (White/Green)
Immersion Length
NSA- -2.5 NSA- -4xxx : 2.5” (63.50 mm) | xxx : 4.0“ (101.60 mm)
NSA- -6xxx : 6.25” (158.75 mm)
Probe Length
NSA- -2.5xxx : - 4.31” (109.47 mm) +/ 0.13” (3.30 mm)
NSA- -4xxx : 5.81“ 0.13” (3.30 mm)(147.57 mm) +/-
NSA- -6xxx : 7.81” (198.37 mm) +/ 0.13” (3.30 mm)-

Thermistor, Immersion
Installation and Operation
#NSA-A/CP-I-2.5- NSA-A/CP-I-4- NSA-A/CP-I-6-4X, 4X, 4X, NSA-HH/CP-I-2.5- -C NSA-HH/CP-I-4- -C PB , PB
NSA-HH/CP-I-6- -C /15/2019 PB –11
Specications subject to change without notice.
Catalog No. - - - Page of 11 808 785 01 2 5
Dimensional Drawing
PLASTIC BOX (-PB)
NEMA -4X (-4X)
Figure 1
Installation
Carrier’s standard Immersion sensors are made to install into a ½” NPT female thread. Typically a Threadolet or Tee is
installed into the pipe, but a hole can also be drilled and tapped.
Figure 2
The pipe/system will need to be drained, unless a Hot Tap is being used. The recommend drill size is 23/32 in. (18 mm).
Drill the hole, and tap the hole with ½”-14NPT. Always use proper thread sealants on tapered pipe threads of the
thermowell. Screw the thermowell into the Threadolet, Tee, or tapped hole, using a wrench to tighten it rmly. Rell the
system and check for leaks. Best practice is to apply thermal grease to the end of the probe, but not required. Insert and
push the sensor probe into the thermowell. Turn the sensor probe assembly clockwise to tighten down completely. Refer
to the to make necessary connections. Wiring Instructions

Thermistor, Immersion
Installation and Operation
#NSA-A/CP-I-2.5- NSA-A/CP-I-4- NSA-A/CP-I-6-4X, 4X, 4X, NSA-HH/CP-I-2.5- -C NSA-HH/CP-I-4- -C PB , PB
NSA-HH/CP-I-6- -C /15/2019 PB –11
Specications subject to change without notice.
Catalog No. - - - Page of 11 808 785 01 3 5
Elbow Assembly
Figure 3
Tee Mount Assembly
Figure 4
Temperature Wiring
Figure 5
Product specificaties
Merk: | Carrier |
Categorie: | sensor |
Model: | NSA-IMM |
Heb je hulp nodig?
Als je hulp nodig hebt met Carrier NSA-IMM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding sensor Carrier

31 Maart 2025

31 Maart 2025
Handleiding sensor
- sensor Panasonic
- sensor Hikvision
- sensor Jung
- sensor Festo
- sensor IFM
- sensor Crestron
- sensor Moen
- sensor Metz Connect
- sensor Chauvin Arnoux
- sensor Sensirion
Nieuwste handleidingen voor sensor

31 Maart 2025

4 Februari 2025

30 Januari 2025

18 December 2024

18 December 2024

18 December 2024

18 December 2024

18 December 2024

18 December 2024

13 December 2024