Powerplus POWXG9565 Handleiding

Powerplus Pomp POWXG9565

Lees hieronder de đź“– handleiding in het Nederlandse voor Powerplus POWXG9565 (6 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 62 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
POWXG9565 EN
Copyright © VARO NV 2020 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 SPECIFIC SAFETY WARNINGS ..................................................... 3
6 ASSEMBLY ...................................................................................... 3
6.1 Electrical connection .............................................................................................. 3
6.2 Assembly of the “Press Controll” .......................................................................... 3
6.3 Earth ........................................................................................................................ 3
7 OPERATION ..................................................................................... 4
7.1 Pressure hose ......................................................................................................... 4
7.2 Safety requirements ................................................................................................ 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Cleaning 5 ...................................................................................................................
9 TECHNICAL DATA .......................................................................... 5
10 NOISE ............................................................................................... 5
11 TROUBLE SHOOTING .................................................................... 6
12 WARRANTY ..................................................................................... 7
13 ENVIRONMENT ............................................................................... 8
14 DECLARATION OF CONFORMITY ................................................ 8
POWXG9565 EN
Copyright © VARO NV 2020 P a g e | 2www.varo.com
PRESSURE PUMP 1200W SS RING HOUSE & GARDEN
POWXG9565
1 APPLICATION
This electrical garden pump with press control is suitable to use outdoors (for example in the
garden).
Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1 On/off switch
2 motor housing
3 water inlet
4 water outlet
5 cable & plug
6 Carrying handle
7 Integrated filter
8 Press controll
3 PACKAGE CONTENT LIST
â–Ş Remove all packing materials
â–Ş Remove remaining packaging and transit supports (if existing)
â–Ş Check the completeness of the packing content
â–Ş Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
â–Ş Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
1 x Water Pump with 1.2m electric cable
1 x press control
1 x Manual
1 x Key for filter cover
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal
injury or damage to the tool.
In accordance with essential
safety standards of applicable
European directives
This appliance cannot be used by children or people who are physically,
mentally or developmentally impaired, or people who lack experience or
knowledge, except in case these people receive instruction from a person
responsible for their safety, a supervisor, or by studying the preceding
instructions concerning use of this appliance.
POWXG9565 EN
Copyright © VARO NV 2020 P a g e | 3www.varo.com
5 SPECIFIC SAFETY WARNINGS
â–Ş This water pump has no water-sprinkling protection feature and should be placed only in a
dry environment. Never place the water pump or operate it in the rain or in a humid space.
â–Ş This water pump should not be used with flammable or harmful liquids.
â–Ş Idle operation of the water pump must be avoided.
â–Ş This water pump is for work in clean water. The scope its application includes irrigation of
in the garden, water supply to a household, sprinkling in a garden or on farmland.
â–Ş This water pump may not be exposed for long periods to impurities, sand, stone, sticky
substances, etc., mixed in with the conveyed media. Because the conveyed media may
contain chemical corrosive substances, it is necessary to pay special attention to
preventing influence by these on the material of the pump body. It is not permitted to use
this water pump to convey drinking water.
â–Ş In order to protect the pump from dry suction, the machine is equipped with a protective
device providing an automatic shutdown in case there is not enough water supply, as this
could cause damage to the pump.
This appliance cannot be used by children or people who are physically,
mentally or developmentally impaired, or people who lack experience or
knowledge, except in case these people receive instruction from a person
responsible for their safety, a supervisor, or by studying the preceding
instructions concerning use of this appliance.
6 ASSEMBLY
â–Ş During the installation of the water pump, the power supply to the water pump must be
switched off.
â–Ş During installation of the equipment, it is necessary to keep it under dry and well-ventilated
conditions, at an ambient temperature below 40°C.
â–Ş If the required pumping water is excessive due to your own action, resulting in flooding of
the irrigation site, a number of protective measures may be taken (e.g. installation of a
device for discharging the excess water, an alarm, standby pump, water container, etc.).
However, our company is not responsible for any losses thus caused.
â–Ş Before use, the water pump should be inspected for safety to ensure that there is no
damage to the power cable or the plug.
6.1 Electrical connection
â–Ş The electrician responsible for installation must check to ensure that the electrical
connection is in accordance with the standard, including the earth terminal.
â–Ş It is necessary to check the rated current of the electric contact with protective switch - this
must be 30mA.
6.2 Assembly of the “Press Controll”
▪ The “press controll” is packed separately in the box. Mount it on the exit (on top) of the
water exit. Fasten the union nut with an adjustable wrench.
6.3 Earth
The water pump must be well earthed. Short-circuiting will render the relevant articles of the
guarantee invalid. If it is necessary to increase the length of the original cable, a cable with the
same section as the original cable must be used.


Product specificaties

Merk: Powerplus
Categorie: Pomp
Model: POWXG9565

Heb je hulp nodig?

Als je hulp nodig hebt met Powerplus POWXG9565 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Powerplus

Handleiding Pomp

Nieuwste handleidingen voor Pomp

Sauermann

Sauermann Omega Handleiding

13 November 2024
Sauermann

Sauermann Delta Handleiding

12 November 2024
Testo

Testo 565i Handleiding

12 November 2024
Simpson

Simpson SCP71008 Handleiding

11 November 2024
MSW

MSW -OP-56-DC Handleiding

5 November 2024
MSW

MSW -FM-N-53 Handleiding

4 November 2024
MSW

MSW -AOP40S Handleiding

15 Oktober 2024
MSW

MSW -MN34M Handleiding

15 Oktober 2024
MSW

MSW -MN34 Handleiding

15 Oktober 2024