Powerplus POWXG9554 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Powerplus POWXG9554 (5 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 93 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/5
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 SPECIFIC SAFETY WARNINGS ..................................................... 3
6 ASSEMBLY ...................................................................................... 3
6.1 Electrical connection .............................................................................................. 3
6.2 Earth ........................................................................................................................ 3
7 OPERATION ..................................................................................... 3
7.1 Pressure hose ......................................................................................................... 4
7.2 Safety requirements ................................................................................................ 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Cleaning 5 ...................................................................................................................
9 TECHNICAL DATA .......................................................................... 5
10 NOISE ............................................................................................... 5
11 TROUBLE SHOOTING .................................................................... 5
12 WARRANTY ..................................................................................... 7
13 ENVIRONMENT ............................................................................... 7
14 DECLARATION OF CONFORMITY ................................................ 8
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 3www.varo.com
5 SPECIFIC SAFETY WARNINGS
▪ This water pump has no water-sprinkling protection feature and should be placed only in a
dry environment. Never place the water pump or operate it in the rain or in a humid space.
▪ This water pump should not be used with flammable or harmful liquids.
▪ Idle operation of the water pump must be avoided.
▪ This water pump is for work in clean water. The scope its application includes irrigation of
in the garden, water supply to a household, sprinkling in a garden or on farmland.
▪ This water pump may not be exposed for long periods to impurities, sand, stone, sticky
substances, etc., mixed in with the conveyed media. Because the conveyed media may
contain chemical corrosive substances, it is necessary to pay special attention to
preventing influence by these on the material of the pump body. It is not permitted to use
this water pump to convey drinking water.
This appliance cannot be used by children or people who are physically,
mentally or developmentally impaired, or people who lack experience or
knowledge, except in case these people receive instruction from a person
responsible for their safety, a supervisor, or by studying the preceding
instructions concerning use of this appliance.
6 ASSEMBLY
▪ During the installation of the water pump, the power supply to the water pump must be
switched off.
▪ During installation of the equipment, it is necessary to keep it under dry and well-ventilated
conditions, at an ambient temperature below 40°C.
▪ If the required pumping water is excessive due to your own action, resulting in flooding of
the irrigation site, a number of protective measures may be taken (e.g. installation of a
device for discharging the excess water, an alarm, standby pump, water container, etc.).
However, our company is not responsible for any losses thus caused.
▪ Before use, the water pump should be inspected for safety to ensure that there is no
damage to the power cable or the plug.
6.1 Electrical connection
▪ The electrician responsible for installation must check to ensure that the electrical
connection is in accordance with the standard, including the earth terminal.
▪ It is necessary to check the rated current of the electric contact with protective switch - this
must be 30mA.
6.2 Earth
The water pump must be well earthed. Short-circuiting will render the relevant articles of the
guarantee invalid. If it is necessary to increase the length of the original cable, a cable with the
same section as the original cable must be used.
7 OPERATION
The pumps are not self-priming pumps. This means that the suction hose should first of all be
fitted with:
1 Non-return valve with filter; this ensures that, after disconnecting the pump, the hose
and the pump do not run dry. This part of the hose is suspended in the water to be
pumped away.
2 Hose with coupling nut; this end of the hose is attached to the front of the pump.
3 Both accessories should be securely screwed on to the hose using a hose clip.
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 5www.varo.com
8 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
8.1 Cleaning
Under normal conditions, the water pump is free of maintenance. However, the pump should
not be placed in the open air during rain, in a humid place, or dirty or frozen environment.
▪ Freezing, idling or blocking by impurities should be avoided.
▪ Always disconnect the power supply before maintenance of the pump.
▪ If the power cable is damaged, it must be replaced by professional personnel. Damage
caused by short circuiting is not included in scope of the guarantee.
▪ If trouble with the pump is experienced, guaranteed repairs must be carried out by an
authorized maintenance center.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9 TECHNICAL DATA
type
POWXG9554
Mains voltage / frequency
230V~ /50Hz
Rated power
1000W
Max. pump capacity
3500 l/hour
Max. lift
44 m
Maximum suction level
7 m
Max. water temperature
35°C
Min. diameter of suction hose
1” (25mm)
Min. diameter of pressure hose
3/ 204” ( mm)
Cable length
1,2 m
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
72 dB(A)
Acoustic power level LwA
86 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
11 TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The electric motor is
running but the pump
does not suck water
After the pump
starts, the pump
body does not fill
with water
Fill the pump with water
Product specificaties
Merk: | Powerplus |
Categorie: | Pomp |
Model: | POWXG9554 |
Heb je hulp nodig?
Als je hulp nodig hebt met Powerplus POWXG9554 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Powerplus
31 Mei 2023
17 Mei 2023
16 Mei 2023
9 Mei 2023
6 Mei 2023
4 Mei 2023
29 April 2023
20 April 2023
20 April 2023
11 April 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
4 December 2024
4 December 2024
30 November 2024
30 November 2024
23 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
18 November 2024