Powerplus POWXG9507 Handleiding

Powerplus Pomp POWXG9507

Lees hieronder de 📖 handleiding in het Nederlandse voor Powerplus POWXG9507 (6 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 SETTING TO WORK ........................................................................ 4
8.1 Venting the pump before use ................................................................................. 4
8.2 Setting the ON/OFF operating point 4 .......................................................................
9 CLEANING AND MAINTENANCE ................................................... 4
9.1 Maintenance guidelines .......................................................................................... 5
9.2 Cleaning the impeller .............................................................................................. 5
10 TECHNICAL DATA .......................................................................... 5
11 SERVICE DEPARTMENT ................................................................ 5
12 TROUBLESHOOTING ..................................................................... 6
13 STORAGE ........................................................................................ 6
14 WARRANTY ..................................................................................... 7
15 ENVIRONMENT ............................................................................... 7
16 DECLARATION OF CONFORMITY ................................................ 8
POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 2www.varo.com
SUBMERSIBLE PUMP 550W
POWXG9507
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding. It is also used wherever water has to be moved from one place to
another, e.g. in the home, agriculture, horticulture, plumbing and many other applications.
Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
7. cable clamp
3 PACKAGE CONTENT LIST
â–ª Remove all packing materials
â–ª Remove remaining packaging and transit supports (if existing)
â–ª Check the completeness of the packing content
â–ª Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
â–ª Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
Submersible pump with 10m electric cable (RNF) with earthed plug
Outlet connection.
manual
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal
injury or damage to the tool.
Read manual before use
POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 4www.varo.com
Mains supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The
pump is designed to be connected to a 230V - 50 Hz earthed socket. Make sure that the
socket is sufficiently secured (min. 6 Amp.) and is in excellent condition. Introduce the plug
into the socket and the pump is ready to go.
Important Note!
If the mains cable or plug suffers any damage from external action, repairs to the cable should
be serviced by a qualified specialist using only standard spare parts. This will ensure that it
meets the required safety standards.
8 SETTING TO WORK
After having read these instructions carefully, you can set your pump to work, reconsidering
the following:
â–ª Check if the pump rests on the ground of the shaft.
â–ª Check of pressure cord has been attached properly.
â–ª Check if electrical connection is 230 V - 50 Hz.
â–ª Check if socket is in good condition.
â–ª Make sure that water and humidity can never come to the mains supply.
â–ª Avoid pump running dry.
8.1 Venting the pump before use
â–ª Always ensure that the pump is vented properly before commissioning the pump. Possibly
tilting back and forth several times until no more air bubbles appear, wait at least 15
seconds before the pump to start.
8.2 Setting the ON/OFF operating point
The ON and OFF operating point of the float switch can be set by adjusting the float switch in
its latching holder.
Before you put the pump into operation, please check the following:
â–ª The float switch must be installed so that the level of the ON operating point and the level
of the OFF operating point can be reached easily and with little force. To check this, place
the pump in a vessel filled with water, raise the float switch carefully by hand and then
lower it again. As you do so, note whether the pump switches on and off.
â–ª Make sure that the distance between the float switch head and the latching holder is not
too small. Proper operation is not guaranteed if the gap is too small.
â–ª en you set the float switch, make sure that it does not touch the base before the pump Wh
switches off. Caution! Risk of dry-running.
This appliance cannot be used by children or people who are physically, mentally or
developmentally impaired, or people who lack experience or knowledge, except in case
these people receive instruction from a person responsible for their safety, a
supervisor, or by studying the preceding instructions concerning use of this appliance.
9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.


Product specificaties

Merk: Powerplus
Categorie: Pomp
Model: POWXG9507

Heb je hulp nodig?

Als je hulp nodig hebt met Powerplus POWXG9507 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Powerplus

Handleiding Pomp

Nieuwste handleidingen voor Pomp