SKLC (Secure Keyed LC) Connector Field Termination
ASSEMBLY INSTRUCTIONS
PREPARE
1. Slide boot onto the ber, with the small end inserted rst, away from the
connector. (FIGURE 1)
NOTE: 900um boots are sold separately.
2. Remove 4 inches of the outer cable sheath for jacketed cable.
3. Strip the 900μm buffer as indicated in the measurements provided in the chart
below (FIGURE 2)*, strip the fiber in increments of ¼”.
4. Clean exposed ber with a lint-free wipe damped with 99% isopropyl alcohol to
remove any contaminants.
NOTE: Images are not to scale.
ASSEMBLE
1. Remove the dust cap from the connector.
2. Dry t the ber by inserting the ber into the connector. This will assure that
all coating has been removed and the ber can be inserted into the connector
ferrule.
3. Shake the adhesive bottle before using. Remove the cap from the adhesive
bottle, and attach the needle by pressing it gently onto the top of the bottle
until you feel it set into place.
NOTE: Syringes are also available for inserting adhesive. See parts list for part
number.
4. Insert the needle into the back of the connector, holding it rmly in place while
lling. Being careful not to over ll the connector, squeeze the bottle gently,
injecting the adhesive into the connector. Continue squeezing until a dot of
adhesive is visible at the ferrule end of the connector, and then remove the
needle. Wipe away any excess adhesive from the end of the ferrule.
4. Hold a lint-free wipe across the nger tips, and then gently press the ferrule
end-face against the wipe. Twist the connector in place to remove any debris.
Do not drag the connector across the lint-free wipe.
5. Wipe the bottom surface of the LC 1.25mm polishing puck and the surface of
the polishing pad with a lint-free wipe damped with 99% isopropyl alcohol to
remove any contaminants.
6. Place the 3μm film on the polishing pad, dull side up. Leviton’s 3μm film is
yellow in color. Place the polishing puck on the lm. Gently insert the
connector ferrule into the polishing puck and using very light pressure, trace 15-
20 figure 8’s on the lm. Inspect to ensure the ber is polished ush by rst
gently dragging the connector across a lint-free wipe. Fiber should not snag. If
the ber snags, continue polishing until it does not snag. Remove debris with a
lint-free wipe dampened with 99% isopropyl alcohol.
7. Repeat steps 5 and 6 with 0.3μm polishing film. Leviton’s 0.3μm film is a light
blue in color.
8. Using a Leviton 200x inspection scope, inspect the ber core to assure the core
is not scratched, cracked, broken and is clean. (FIGURE 4)
9. Replace the dust cap on the connector to maintain cleanliness.
INSPECTING THE BACKLIT FIBER:
SCRIBE AND PULL FIBER AWAY
Multimode 62.5/125 Singlemode 9/125
4
White area must be free
of all obstruction. Grey
area should be free of
scratches and dark
spots.
ALL BUFFERED CABLE
PK-93775- - -10 02 0A
For more information please contact tech support at: 1-800-824-3005 or visit: www.leviton.com
IMPORTANT INSTRUCTIONS
1. Read and understand all instructions. Follow all warnings and instructions marked on the product.
2. Do not use this product near water-e.g., near a tub, wash basin, kitchen sink or laundry tub, in a
wet basement, or near a swimming pool.
3. Never push objects of any kind into this product through openings, as they may touch dangerous
voltage s.
4. SAVE THESE INSTRUCTIONS.
SAFETY INFORMATION
1. Never install communications wiring or components during a lightning storm.
2. Never install communications components in wet locations unless the components are designed
specically for use in wet locations.
3. Never touch uninsulated wires or terminals unless the wiring has been disconnected at the network
interface.
4. Use caution when installing or modifying communications wiring or components.
5. To prevent electrical shock, each opening must be lled with a module.
5
6
8
7
10
INSTALLING THE SECURED KEYED LC HOUSING
NOTE: Assure correct connector polarity prior to nal assembly of the housing; refer
to (FIGURE 5). Failure to do so may result in the need to disassemble the
Secured LC housing, which will result in damage to the housing.
1. Place the upper housing with the top of the housing down on the work surface
(FIGURE 6).
2. Insert the rst ber connector, with the LC latch facing down, into the correct
connector slot in the upper housing, making sure the retention slots on the
connector are aligned with the capture feature in the housing (FIGURE 7).
3. Now insert the second fiber connector, with the LC latch facing down, into the correct
connector slot in the upper housing, making sure the retention slots on the
connector are aligned with the capture feature in the housing (FIGURE 8).
4. Insert the Assembly Alignment Guide into the lower housing, from the bottom
(FIGURE 9).
5. Place the lower housing over the upper housing with the Assembly Alignment Guide
positioned so it will t into the alignment slot into the upper housing (FIGURE 10).
6. Place the housing assembly between your thumb and ngers, gently squeeze the
upper and lower housing assemblies together until the retention snaps lock the
upper and lower housing together.
7. Remove the Assembly Alignment Guide from the connector housing.
NOTE: Always inspect the ber connector before inserting into an adapter. Leviton
200x scope with duplex adapter is specically designed to allow inspection
of duplex connector pairs.
NOTE: Once a connector is engaged into an adapter, an extraction tool of the
same keyed color is required to disengage from the adapter
FIBER STRAND POLARITY
Proper polarity of the ber strands is required to assure transmit and receive
functionality. See gure 5.
The numbered strands (i.e. 1, 3, 5,) of the fiber cable typically are placed in odd
the A polarity position. The numbered strands (i.e. 2, 4, 6,) of the ber cable even
typically are placed in the B polarity position. This should result in proper A-B
polarity alignment.
Secure Keyed LC Kits & Accessories
Part No.
Secure Keyed LC Connector Kit, 900um, MM/SM - black
4999K
ELC
Secure Keyed LC Connector Kit, 900um, MM/SM - green
4999K
VLC
Secure Keyed LC Connector Kit, 900um, MM/SM - blue
4999K
LLC
Secure Keyed LC Connector Kit, 900um, MM/SM - orange
4999K
OLC
Secure Keyed LC Connector Kit, 900um, MM/SM - red
4999K
RLC
Secure Keyed LC Connector Kit, 900um, MM/SM - slate
4999K
GLC
Secure Keyed LC Connector Kit, 900um, MM/SM - white
4999K
WLC
Secure Keyed LC Connector Kit, 900um, MM/SM - yellow
4999K
YLC
900μm Boot, Blue (bag of 50)
4999K
BLU
900μm Boot, Beige (bag of 50)
4999K
BGE
900μm Boot, Black (bag of 50)
4999K
BLK
900μm Boot, Aqua (bag of 50)
4999K
AQU
Extraction Tool with Dust Cap
ETRTN
*TL
* = W (white), Y (yellow), O (orange), R (red), L (blue), V (green), G (slate), E (black)
Fiber Installation Tools
Part No.
Fast Cure Tool Kit
49800
FTK
Adhesive Primer Kit
49800
680
Fast Cure Consumables Kit
49800
FAC
200x Fiber Inspection Scope
49886
FSP
Duplex LC Scope Adapter (for use with Leviton 200x Scope)
49886
LCD
LC Polishing Puck
49886
LCP
Fast Cure Carrying Case
49886
FCC
Replacement Needles
49886
FCN
Syringes (bag of 25)
49886
SYR
INSIDE
OF TOP
HOUSING
9
PK-93775- - -10 02 0A


Product specificaties

Merk: Leviton
Categorie: Niet gecategoriseerd
Model: 4999K-OLC
Kleur van het product: Oranje
Duurzaamheidscertificaten: RoHS
Aantal per verpakking: 1 stuk(s)
Naleving van duurzaamheid: Ja
Geslacht connector: Mannelijk
Draad modus structuur: Multi-mode, Single-mode
Aansluiting type: LC
Connector-materiaal: Zirkonia

Heb je hulp nodig?

Als je hulp nodig hebt met Leviton 4999K-OLC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Leviton

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

MSW

MSW -HRH-600 Handleiding

5 November 2024
MSW

MSW -PCJ-302 Handleiding

5 November 2024
MSW

MSW -ETT-22 Handleiding

5 November 2024
DoorBird

DoorBird MTM56A Handleiding

5 November 2024
Hacienda

Hacienda PWB801 Handleiding

5 November 2024
Hacienda

Hacienda PWB802 Handleiding

5 November 2024
MSW

MSW -ECF1-01 Handleiding

5 November 2024
MSW

MSW -MWC-01 Handleiding

5 November 2024
MSW

MSW -TM01 Handleiding

5 November 2024