WS- -6020U IT www.lacrossetechnology.com/support Page | 1
Model: WS- U- 6020 IT
Instruction Manual
DC: 112116
Solar Powered Wireless Temperature
Station & Sensor
G et Started
1. Insert the 2 "AA" Rechargeable Alkaline batteries (included) into
the solar station. Observe the correct polarity.
2. Next, slide the battery switch to the SOLAR Position (UP).
3. Gently p on the Sensor to activateress the RESET button .
4. After 5 minutes place sensor outside in a shaded location.
Note: Do not use sharp objects to press the RESET button. Use a
small dull pointed object or a straightened paper clip to gently press
the RESET button
Restart: If the outdoor temperature shows dashes, remove batteries
from the temperature station and move battery switch to the DOWN
position. Press any button on the temperature station times. After 20
15 minutes, return to s tep 1 above.
T U-X62 IT
Sensor
Alkaline
Rechargeable
Batteries NOT
replaceable
Outdoor
Temp
.
Solar
panels
Indoor
Temp.
MIN & MAX
Outdoor or
Indoor Temp
.
Solar panel
2- AA Batteries
Rechargeable
Batteries
Included
RESET
button
Battery
Switch
Note: This station reads in °F only.
WS- -6020U IT www.lacrossetechnology.com/support Page | 2
Setup with Standard Alkaline Batteries
1. Insert the 2 "AA" Alkaline batteries (not included) into the solar
station. Observe the correct polarity.
2. Gently press the RESET button on the Sensor to activate.
3. After 5 minutes place sensor outside in a shaded location.
MIN/MAX Readings
View: Press the MIN/MAX button to view:
Outdoor Temperature minimum and maximum.
Indoor temperature minimum and maximum.
Reset MIN/MAX: Hold the MIN/MAX button for 5 seconds to reset
the indoor and outdoor minimum and maximum temperatures to
current temperatures.
Position Outdoor Sensor
It is important to place the sensor in a bright environment for the
solar panel to collect enough light to recharge the internal power
cell.
WARNING: Do NOT recharge the
Solar
- rechargeable batteries
(included) outside of this product
because it will damage the batteries
and other charging devices.
SWITCH UP
(SOLAR- RECHARGEABLE BATTERIES)
Slide the battery switch to UP position once
solar
-rechargeable batteries are inserted.
SWITCH DOWN
(START
-UP / RESET) (STANDARD ALKALINES)
Slide switch to DOWN position before
(1) start- up / reset or (2) any type of battery replacement
WS- -6020U IT www.lacrossetechnology.com/support Page | 3
Mount the outdoor sensor on a east facing wall for cool morning -
sun or in any well shaded area. Under an eave or deck rail is
preferred.
The maximum transmitting range to the temperature station is
over 200 feet (60 meters) in open air, not including walls.
Low Battery Icon
Displayed when the solar station battery s low.i
Rechargeable Batteries: Place solar station under a lamp
(solar panels up) for 24 hours to charge. (Do not place in
battery charger)
Standard Alkaline Batteries: Replace with fresh batteries.
Displayed when the transmitter battery is low.
Place sensor under a lamp (solar panel up) for 24 hours to
charge.
High-efficiency modern solar panels on the solar station and sensor
maintain full charge with minimal light
WARNING!
"Do NOT recharge the included solar rechargeable batteries in
any device other than the product they came with.
Recharging the rechargeable solar batteries in battery chargers
or other third party devices will damage the batteries and
charging device."
Power Save Mode - Solar Station
The LCD of the solar station will automatically turn OFF if the
environment is dark to save power.
The LCD will automatically turn ON when the environment is bright
enough.
This “green” feature is not adjustable.
Note: If the solar panel is facing a permanent strong light source
(e.g., on top of a refrigerator with halogen lamp), please switch the
solar station to alkaline battery mode to avoid over- charging the
re-chargeable alkaline battery.
Stop Mode
If the solar station is placed in a dark environment for 72 hours
continually, the station will go to the stop mode:
The solar station will not perform any operation and the LCD will
also be OFF.
Press the MIN/MAX button to wake up the solar station.


Product specificaties

Merk: La Crosse Technology
Categorie: Niet gecategoriseerd
Model: WS-6020U-IT

Heb je hulp nodig?

Als je hulp nodig hebt met La Crosse Technology WS-6020U-IT stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd La Crosse Technology

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024
Senal

Senal ME-220-CL Handleiding

21 November 2024
Senal

Senal ASM-4 Handleiding

21 November 2024