La Crosse Technology TX23U Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor La Crosse Technology TX23U (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
TX-23U WIND SENSOR
TX-23U WIND SENSOR
TX-23U WIND SENSOR
TX-23U WIND SENSOR TX-23U WIND SENSOR
The TX-23U wind sensor is used in conjunction with the TX22U relay
transmitter to gather and transmit information to the WS-1610
wireless weather station.
INVENTORY OF CO
INVENTORY OF CO
INVENTORY OF CO
INVENTORY OF COINVENTORY OF CONTENTS
NTENTS
NTENTS
NTENTS NTENTS
1. TX-23U wind sensor
2. Mounting bracket
3. Mounting hardware
4. Instruction manual and warranty card
SETTING UP
SETTING UP
SETTING UP
SETTING UP SETTING UP
When putting the Weather Station into operation, it is important to
perform in close proximity (e.g. on a table) a complete wiring and set-
up of the system. This step is important to test all components for
correct function before placing and mounting them at their final
destinations.
1. Unwind the cables of the Rain and the Wind sensors. Connect
the Rain and the Wind sensors to the Thermo-hygro transmitter
by plugging the connector heads of the two sensors into the
appropriate sockets of the Thermo-hygro transmitter. Be sure
they “click” into place.
2. First insert the batteries into the Thermo-hygro transmitter .
3. Then insert the batteries into the Weather Station. Once the
batteries are installed, all segments of the LCD will light up briefly
and a short signal tone will be heard. It will then display the time
as 12:00, the date as 1.1.05, the weather icons, and air pressure
value. "- - -" will be shown for outdoor data.
4. Afterwards, the Weather Station will start receiving data from the
transmitter. The outdoor temperature, humidity wind chill and
wind speed should then be displayed on the Weather Station. If
this does not happen after 30 seconds, the batteries will need to
be removed from both units. You will have to start again from
step 1.
5. You may then check all cables for correct connection and all
components for correct function by manually turning the wind-
gauge, moving the weather-vane, tilting the rain sensor to hear
the impact of the internally moving seesaw, etc.
6. Time and date shall be manually set.
7. After the Weather Station has been checked for correct function
with regard to the above points and found fit, the initial set up of
the weather station system is finished and the mounting of the
system components can take place. It must be ensured however
that all components work properly together at their chosen
mounting or standing locations. If e.g. there appear to be
problems with the 915 MHz radio transmission, they can mostly
be overcome by slightly changing the mounting locations.
Note:
The radio communication between the receiver and the transmitter in
the open field reaches distances of max 330 feet (100 metres),
provided there are no interfering obstacles such as buildings, trees,
vehicles, high voltage lines, Ham radio antennae, etc.
8.
Radio interferences created by PC screens, cordless phones,
radios or TV sets can in some cases entirely cut off radio
communication. Please take this into consideration when
choosing standing or mounting locations.
Note :
•
After batteries are installed in transmitter, user shall also power
up the weather station to receive the signal from the transmitter
as soon as possible. If the weather station is powered after about
more than 5 hours the transmitter is powered, the weather station
will never receive signal successfully from this transmitter. In this
case, user will need to reinstall the batteries from the transmitter
to redo setting-up procedures.
•
Detailed Set up procedures of the Weather Station, the
Thermo-hygro Transmitter, the Rain sensor and the Wind
Sensor refer to the main operation manual of WS-1610.
MOUNTING
MOUNTING
MOUNTING
MOUNTING MOUNTING
Mount at least 3 feet above the roofline of your house. Please be sure
there is clear area in every direction from buildings, trees, hills etc.
Thread the cord through the mounting bracket and attach bracket to a
mast no larger than 1 1/8 inch in diameter. Please note the N,S,E,W
on the sensor. The mounting bracket will be on the West side for
correct direction. When plugging into the TH sensor be sure the cord
“clicks” into place. You may need to use a pen to push it in.
Note:
Before permanently mounting ensure that the indoor weather station is
able to receive WWVB signals from the desired location. Also,
extreme and sudden changes in temperature will decrease the
accuracy of the indoor weather station, and changes in elevation will
result with inaccurate weather forecasting for the next 12 to 24 hours.
These changes will require a 12 to 24 hour wait before obtaining
reliable data. To achieve a true temperature reading, avoid mounting
where direct sunlight can reach the relay transmitter or indoor weather
station. While the relay transmitter is weather proof, avoid submersion
in water or snow. We recommend that you mount the relay transmitter
on an outside North-facing wall, 12 inches below the eaves. The
sending range is 330 ft obstacles such as walls, concrete, and large
metal objects can reduce the range. Place both units in their desired
location, and wait approximately 15 minutes before permanently
mounting to ensure that there is proper reception. The indoor weather
station should display a temperature and humidity in the OUTDOOR
LCD and wind speed (can be 0.0) in the WIND SPEED LCD within 4
minutes of setting up.
The remote wind speed sensor can be mounted two ways:
•
With the use of screws
•
Using nylon straps
Horizontal panel
Wind
vane
Fixed with
screw
Vertical mast
Wind fan Fixed with
Nylon strap
Cable connection
between the wind sensor
and the thermo-hygro
transmitter
Cable connection
between the rain sensor
and the thermo-hygro
transmitter
Wireless transmission a
t
915 MHz - thermo-hygro
transmitter to weathe
r
station
Weather station
Wind sensor
Rain senso
r
Battery (Weather Station):
3 x AA, IEC LR6, 1.5V
Battery:
2 x AA, IEC LR6, 1.5V
Sockets for wind and
rain sensor
A. MOUNTING WITH SCREWS
1. Unlock the mounting bracket from the remote wind speed
sensor leaving the wire going through the bracket.
2. Place the mounting bracket over the desired location.
3. Through the two screw holes of the bracket, mark the
mounting surface with a pencil.
4. Screw the mounting bracket onto the mounting surface.
Ensure that the screws are tight against the bracket.
5. Slide the remote wind speed sensor onto the bracket making
sure to lock it in place.
B. MOUNTING WITH NYLON STRAPS
1. Unlock the mounting bracket from the remote wind speed
sensor leaving the wire going through the bracket.
2. Place two nylon straps through the slots on the mounting
bracket.
3. Place the remote wind speed sensor in your desired location.
4. Fasten the two nylon straps securely around the mounting
location.
5. Slide the remote wind speed sensor onto the bracket making
sure to lock it in place.
MAINTENANCE AND CARE
MAINTENANCE AND CARE
MAINTENANCE AND CARE
MAINTENANCE AND CARE MAINTENANCE AND CARE
1. Extreme temperatures, vibrations, and shock should be avoided
to prevent damage to the units
2. Clean displays and units with a soft, damp cloth. Do not use
solvents or scouring agents, they may mark the displays and
casings
3. Do not submerge in water.
4. Do not subject the units to unnecessary heat or cold by placing
them in the oven or freezer.
5. Opening the casings invalidates the warranty. Do not try to repair
the unit. Contact La Crosse Technology for repairs.
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS SPECIFICATIONS
Note:
Detailed Specification of the Weather station, the Thermo-hygro
Transmitter, the Rain sensor and the Wind sensor refer to the
main operation manual of WS-1610.
Wind measurement:
Wind Speed range: 0 to 111.8 mph (0 to 50 m/s)
(displayed "OF.L" when > 50m/s)
Units: km/h, m/s, mph & Beaufort
Resolution: 0.1 m/s / 0.1 mph / 0.1 km/h
Wind Direction: By compass scale of 16 divisions
Wind speed checking
interval: Every 4.5 seconds
Transmission range: 330 feet (100 meters) in open space
Power Supply:
Remote wind speed
sensor: Supplied by remote Relay Transmitter
Dimensions (H x W x D):
Remote wind speed
sensor:
9.84" x 6.45" x 7.58" (250 x 164 x
192.7 mm)
WARRANTY INFORMATION
WARRANTY INFORMATION
WARRANTY INFORMATION
WARRANTY INFORMATION WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this
product against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid
only on products purchased and used in North America and only to
the original purchaser of this product. To receive warranty service, the
purchaser must contact La Crosse Technology, Ltd for problem
determination and service procedures. Warranty service can only be
performed by a La Crosse Technology, Ltd authorized service center.
The original dated bill of sale must be presented upon request as
proof of purchase to La Crosse Technology, Ltd or La Crosse
Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our
option and at no charge as stipulated herein, with new or
reconditioned parts or products if found to be defective during the
limited warranty period specified above. All replaced parts and
products become the property of La Crosse Technology, Ltd and must
be returned to La Crosse Technology, Ltd. Replacement parts and
products assume the remaining original warranty, or ninety (90) days,
whichever is longer. La Crosse Technology, Ltd will pay all expenses
for labor and materials for all repairs covered by this warranty. If
necessary repairs are not covered by this warranty, or if a product is
examined which is not in need or repair, you will be charged for the
repairs or examination. The owner must pay any shipping charges
incurred in getting your La Crosse Technology, Ltd product to a La
Crosse Technology, Ltd authorized service center. La Crosse
Technology, Ltd will pay ground return shipping charges to the owner
of the product to a USA address only.
Your La Crosse Technology, Ltd warranty covers all defects in
material and workmanship with the following specified exceptions: (1)
damage caused by accident, unreasonable use or neglect (including
the lack of reasonable and necessary maintenance); (2) damage
occurring during shipment (claims must be presented to the carrier);
(3) damage to, or deterioration of, any accessory or decorative
surface; (4) damage resulting from failure to follow instructions
contained in your owner’s manual; (5) damage resulting from the
performance of repairs or alterations by someone other than an
authorized La Crosse Technology, Ltd authorized service center; (6)
units used for other than home use (7) applications and uses that this
product was not intended or (8) the products inability to receive a
signal due to any source of interference. This warranty covers only
actual defects within the product itself, and does not cover the cost of
installation or removal from a fixed installation, normal set-up or
adjustments, claims based on misrepresentation by the seller or
performance variations resulting from installation-related
circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY
FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER
SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR
MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO
BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC
INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF
CHILDREN’S REACH.
This warranty gives you specific legal rights. You may also have other
rights specific to your State. Some States do no allow the exclusion of
consequential or incidental damages therefore the above exclusion of
limitation may not apply to you.
For warranty work, technical support, or information contact:
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
e-mail:
support@lacrossetechnology.com
(warranty work)
sales@lacrossetechnology.com
(information on other products)
web:
www.lacrossetechnology.com
FCC DISCLAIMER
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
All rights reserved. This handbook must not be reproduced in any
form, even in excerpts, or duplicated or processed using electronic,
mechanical or chemical procedures without written permission of the
publisher.
This handbook may contain mistakes and printing errors. The
information in this handbook is regularly checked and corrections
made in the next issue. We accept no liability for technical mistakes
or printing errors, or their consequences.
All trademarks and patents are acknowledged.


Product specificaties

Merk: La Crosse Technology
Categorie: Niet gecategoriseerd
Model: TX23U

Heb je hulp nodig?

Als je hulp nodig hebt met La Crosse Technology TX23U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd La Crosse Technology

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd