La Crosse Technology TX141-BV4 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor La Crosse Technology TX141-BV4 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 60 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
WIRELESS
TEMPE RATURE S ENSO R
Model: TX141-B4
DC: 081221
WARR A N T Y I N F O
La Crosse Technology, Ltd. provides a (from date of purchase) on this 1-year limited time warranty
product relating to manufacturing defects in materials & workmanship.
For Full Warranty Details, Visit: www.lacrossetechnology.com/support
CARE + M AI N T E NAN CE
When batteries of dierent brand or type are used together, or new and old batteries are used
together, some batteries may be over-discharged due to a dierence of voltage or capacity. This can
result in venting, leakage, and rupture and may cause personal injury.
Always purchase the correct size and grade of battery most suitable for the intended use.
Always replace the whole set of batteries at one time, taking care not to mix old and new ones, or
batteries of dierent types.
Clean the battery contacts and also those of the device prior to battery installation.
Ensure the batteries are installed correctly with regard to polarity (+ and -).
Remove batteries from product during periods of non-use.
Battery leakage can cause corrosion and damage to this product.
Remove used batteries promptly.
For recycling and disposal of batteries, and to protect the environment, please check the
internet or your local phone directory for local recycling centers and/or follow local government
regulations.
FCC STAT E M E N T
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1 ) This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
Caution!
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
WARNING: This product can expose you to chemicals including styrene, which is known to
the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov
Page | 4
Power up
Insert 2-AA batteries into your Outdoor Sensor. Option 1:
• Install one mounting screw into a wall.
• Place the transmitter onto the screw.
Option 2:
• Insert the mounting screw through the front of the sensor and into
the wall.
• Tighten the screw to snug (do not over tighten).
• Mount the temperature sensor on a north-facing wall or in any
well shaded location. Sun will make it read high.
• Under an eave or deck rail is preferred.
• Be sure the outdoor sensor is mounted vertically to drain
moisture.
• The maximum wireless transmission range to the weather station
is over 330 feet (100 meters) in open air, not including walls or
floors.
Watch sensor mounting video: bit.ly/TH_SensorMounting
Refer to the owner’s manual for your clock or weather station to
see if you can Search for Sensor. If so, enable a search and press
the TX button (transmission) on your sensor.
If there is no Search option, try this:
1. Bring your sensor inside next to the station and remove
batteries from both devices.
2. Press any button at least 20 times, and then wait 15 minutes.
3. After the wait, install fresh batteries into both your sensor and
station. Your outdoor temperature should return within the next
few minutes.
4. Keep your sensor next to the station for another 15 minutes to
establish a strong connection.
5. Once connection is reestablished, place sensor outside in a
shaded location.
Power up as a Replacement Sensor
Position Sensor
Specications
Temperature range: -40°F to 140°F (-40 °C to 60 °C)
Transmission range: Up to 330 feet
Transmission frequency: 433 MHz
Power requirements: 2 “AA” Alkaline batteries (not included)
Dimensions: 1.58” L x 0.83” W x 5.08” H
Page | 2 Page | 3
AA
AA
TX button
(Transmission
LED


Product specificaties

Merk: La Crosse Technology
Categorie: Niet gecategoriseerd
Model: TX141-BV4

Heb je hulp nodig?

Als je hulp nodig hebt met La Crosse Technology TX141-BV4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd La Crosse Technology

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd