KN-WS300
(p. 2)
WEATHER STATION
(S. 7)
WETTERSTATION
(p. 12)
STATIONTÉO
(p. 17)
WEERSTATION
(p. 22)
STAZIONE METEOROLOGICA
(p. 27)
ESTACIÓN METEOROLÓGICA
(32. o.)
IDŐJÁRÁSJELZŐ ÁLLOMÁS
(s. 37)
ÄASEMA
(s. 42)
VÄDERSTATION
(s. 47)
METEOROLOGICKÁ STANICE
(p. 52)
APARAT METEO
2
ENGLISH
A. Main Function:
1. Weather forecast for 4 states: sunny, semi-sunny, cloudy, rainy.
2. Function keys: SET, ALARM, CH, ALERT, MAX/MIN, UP, SNOOZE.
3. Seven languages to show the day: English, Germany, French, Italian, Spanish, Dutch,
Danish.
4. Perpetual calendar from year 2000 to 2099.
5. Indoor temperature range: 0°C ~ 50°C, sampling cycle: 15 seconds.
6. Indoor humidity range: 20% ~ 95%, sampling cycle: 15 seconds.
7. Outdoor temperature with RF: up to 3 channels.
8. Outdoor humidity range: 20% ~ 95%.
9. Indoor/outdoor thermometer trend indicator.
10. Indication of the comfort index.
11. Max/min temperature/humidity records.
12. Indoor outdoor max/min temperature alert.
13. The function of Alarm/ Snooze.
14. 12/24 hour selectable
15. Moon phase.
16. Sound controlled LED light
17. World time zone set, -12/+12 hours.
Power-On and reset
1. When Power-On and reset, LCD full display for 3 seconds enter the normal state after
“Beep” → → check temperature and humidity automatic enter into the RCC after received RF
3 minutes later
2. The calendar defaults 0:00 January 1, 2007
3. Alarm defaults 0:00
4. The weather icon defaults semi-sunny
5. Temperature scales defaults Celsius degree °C. Time system defaults 24Hr. RF defaults
CHANNEL1
Instruction of operating the KEYS
3.1 Key functions
Functional keys: Set, Alarm, CH, Up, Snooze, Channel, Max/Min
3
Set Alarm Up C/F
Down
SNOOZE CH Alert Max/Min
standard
Click ----- Alarm on/off 12hr/24hr
switch able
°C/°F switch
able
Back Light/
enter
Snooze
Switch to
CH1, CH2,
CH3
On/Off
temperature
Alarm
Display
max/min
Hold enter into
clock setting
enter into
alarm
setting
----- Enter
into RCC
directly
----- Clear
current
registered
Into
temperature
alarm setup
clear max/
min
Times
Click Con rm
the setting
item
----- one step
forward
one step
backward
Back light ----- ----- -----
Hold ----- ----- 8steps/
second
forward
8steps/
second
backward
----- ----- ----- -----
Alarm set
Click ----- con rm the
setting item
one step
forward
One step
backward
Back light ----- ----- -----
Hold ----- ----- 8steps/
second
forward
8steps/
second
backward
----- ----- ----- -----
Temp alert set
Click ----- ----- one step
forward
one step
backward
Back light Choose
needed
channel
Con rm
the Setting
item
-----
Hold ----- ----- 8steps/
second
forward
8steps/
second
backward
----- ----- ----- -----
3.2 Normal states
1. Hold “SET” to enter into time setting.
2. Click “Alarm to switch the alarm on/off.
3. Hold “Alarm ” for more than 2 seconds to enter into Alarm setting.
4. Click “Up” to switch between 12hr/24hr.
5. Press “C/F Down” to switch between °C/°F.
6. Press “Channel” to switch RF channel, CH1 CH2 CH3.→ →
7. Press ”ALERT” key to switch temperature alarm on/off.
8. Hold ”ALERT” key 2 seconds to enter temperature alarm setting.
9. Press ”MAX/MIN” key to check maximal and minimum of temperature and humidity.
10. Hold ”MAX/MIN” key 2 seconds to clear all record of temperature and humidity.
11. The backlight will be turn on when sound controlled switch able will be put “on”.
12. The backlight will be turn off when sound controlled switch able will be put “off ”.
13. Hold “CH” key for 2 seconds to clear out all data of current “Channel”.
14. When it is receiving signals, press “Down” key more than 2s will exit RCC receiving status.
15. When ALARM rings, click “SNOOZE” to enter into the snooze state every 5 minutes.
3.3 Time set
1. Hold “SET” key for 2 seconds to enter into time setting.
2. The sequence of time setting: OFFSET minute Hour Year(2000-2099) Month
Date Language Exit. → →
3. There will have 1Hz ashing during setting.
4. Press “SET” to confi rm the setting, and enter the next setting state.
5. Press “Up” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will
run forward by 8 steps/second.
6. Press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run
back by 8 steps/second.
7. Moon phase is changed according to year, month, date.
8. The system will exit automatically if no key is operated in 8 seconds.


Product specificaties

Merk: Konig
Categorie: Weerstations
Model: KN-WS300
Kleur van het product: Zwart, zilver
Breedte: 85 mm
Diepte: 34 mm
Hoogte: 185 mm
Meeteenheid temperatuur: F, °C
Alarm functie: Ja
Klok functie: Ja
Type batterij: AA
Temperature measurement range (outside) (T-T): -20 - 60 °C
Temperature measurement range (inside) (T-T): 0 - 50 °C