Konig KN-WS200 Handleiding
Konig
Weerstations
KN-WS200
Lees hieronder de 📖 handleiding in het Nederlandse voor Konig KN-WS200 (56 pagina's) in de categorie Weerstations. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/56
KN-WS200
(p. 2)
RADIO-CONTROLLED CLOCK
(S. 6)
FUNKGESTEUERTE UHR
(p. 11)
HORLOGE RADIO-COMMANDÉE
(p. 16)
RADIOGESTUURDE KLOK
(p. 21)
OROLOGIO RADIOCONTROLLATO
(p. 25)
RELOJ CONTROLADO POR RADIO
(30. o.)
RÁDIÓVEZÉRELT ÓRA
(s. 35)
RADIO-OHJATTU HERÄTYSKELLO
(s. 39)
RADIOSTYRD KLOCKA
(s. 43)
RÁDIEM ŘÍZENÉ HODINY
(p. 47)
CEAS COMANDAT PRIN RADIO
52
ΡΑΔΙΟ-ΕΛΕΓΧΌΜΕΝΟ ΡΟΛΌΙ
2
ENGLISH
A. Main Function:
1. Radio-controlled function in DCF format
2. Weather forcast for 4 states: sunny, semi-sunny, cloudy, rainy
3. Indoor trend indication of temperature/humidity
4. indication of the comfort index
5. Temperature detect range: -20°C ~ 50°C
6. Humidity detect range : 10% RH ~ 95% RH
7. Alarm, snooze (delay 5 minutes alarm)
8. Day of the week in 7 languages
9. LED backlight
10. DST-Daylight saving time
11. Moon phase
12. Word time zone set, -12/+12 hours
B. Power on & Reset
1. While Power-On or reset, the LCD is completely lit for 3 seconds, and after the beep, RCC
receiving mode is activated.
C. Instruction of operating the keys
1. Key functions: Eight functional keys: CLOCK; ALARM; UP; DOWN; 12/24; MAX/MIN;
SNZ/LIGHT; C/F.
Function
Operation
CLOCK ALARM UP DOWN SNZ/LIGHT 12/24 C/F MAX/MIN
Standard mode
Click -------- Alarm on/off -------- -------- Backlight on 12/24
switchable
°C /°F
switch
Display
MAX/MIN
Temperature
and humidity
Hold Enter time
setting
Enter Alarm
Setting
-------- Enter RCC state
forcefully
-------- -------- -------- Clear Max/min
Temperature
and humidity
Time set
Click Confi rm The
setting
-------- One step
forward
One step
backward
Backlight on -------- -------- --------
Hold -------- -------- 8steps/second
forward
8steps/second
backward
-------- -------- -------- --------
Alarm set
Click -------- Confi rm the
setting
One step
forward
One step
backward
Backlight on -------- -------- --------
Hold -------- -------- 8steps/second
forward
8steps/second
backward
-------- -------- -------- --------
2. Standard mode key operation:
a. Hold CLOCK 2 seconds, enter time setting.
b. Press ALARM, turn alarm on/off.
c. Hold ALARM 2 seconds, enter alarm setting.
d. Press 12/24 to switch 12/24HR under time set mode.
e. Press C/F to switch °C/°F.
f. Press SNZ/LIGHT to turn on backlight 5 seconds.
g. When the alarm activates, press SNZ/LIGHT key. Don‘t press any key, the Snooze function
will activate and repeat four times.
h. Press “down” key for 3 seconds to enter into RCC receiving mode.
i. Press “MAX/MIN” key to check maximal and minimum of temperature and humidity.
j. Hold “MAX/MIN” key 2 seconds to clear all record of temperature and humidity
3
k. Under the RCC receiving mode, press “DOWN” key 2 seconds to exit the RCC receiving
mode.
3. Time setting:
a. Hold CLOCK 2 seconds, enter time setting mode.
b. Setting sequence is: Year → Month → Date → Language → Hour → Minute → exit
c. Push CLOCK key to confi rm current setting and enter next setting
d. Click UP key, the setting will go ahead one step; Hold this key 2 seconds, the setting will run
forward by 8 steps/second.
e. Click DOWN key, the setting will backward for one step; Hold this key, the setting will run back
by 8 steps/second.
f. The system will exit automatically if no key is operated in 20 seconds.
4. Alarm setting:
a. Hold ALARM 2 seconds to enter alarm setting.
b. Setting sequence is : hour → minute → exit.
c. Click ALARM to confi rm setting and enter next setting state.
d. Click UP key, the setting will go ahead one step; Hold this key 2 seconds, the setting will run
forward by 8 steps/second.
e. Click DOWN key, the setting will backward for one step; Hold this key, the setting will run back
by 8 steps/second.
f. The system will save the setting and exit automatically if no key is operated in 20 seconds.
D. Function and effect
1. RCC receiving function:
a. How to enter RCC receiving status.
I. It will into RCC receiving state automatically when power on or resetting.
II. It enters RCC receiving automatically at 2:00, 3:00, 4:00, 5:00 everyday.
b. RCC receiving time is 7 minutes.
c. It will receive radio signal automatically at 1:00-3:00 am, if it doesn‘t receive radio signal it will
start receiving at 4:00 and 5:00, if the signal has been received then the next RCC receiving
time is 1:00 am next day.
d. If can’t receive radio signal during 1:00 to 5:00, then next RCC receiving time is 1:00 next
day.
e. If the alarm rings during RCC receiving, system will exit RCC receiving and enter alarm
function.
f. When the DST signal is received, the DST symbol on the LCD will light, and the setting is
changed into daylight saving time.
g. If you change the time setting when the RCC symbol is lit, all the RCC symbols on the display
will be switched off.
2. Alarm function:
a. the BUZZER will ring for 2 seconds as below:
0 – 10 sec.: one “beep” per second
10 – 20 sec.: two “beeps” per second
20 – 30 sec.: four “beeps” per second
after 30 sec.: “beeps” continuously
b. When ringing, click SNZ/LIGHT key once to enter states 5 minutes snooze states, exit if any
other key is pushed.
3. System will stop temperature detection when RCC receiving or alarm ringing.
4. The indoor temperature display range: 0°C -- +50°C (32F -- +122F)
5. The indoor temperature proposed operating range: 0°C -- +40°C (32F -- +104F)
6. The indoor humidity range: 20% --- 95%
Product specificaties
Merk: | Konig |
Categorie: | Weerstations |
Model: | KN-WS200 |
Kleur van het product: | Zwart, zilver |
Breedte: | 85 mm |
Diepte: | 34 mm |
Hoogte: | 185 mm |
Soort: | Digitale tafelklok |
Vormfactor: | Vierkant |
Agenda: | Ja |
Ondersteund aantal accu's/batterijen: | 2 |
Aantal per verpakking: | 1 stuk(s) |
Wekker: | Ja |
Backlight: | Ja |
Thermometer: | Ja |
Type batterij: | AA |
Heb je hulp nodig?
Als je hulp nodig hebt met Konig KN-WS200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstations Konig
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
Handleiding Weerstations
- Weerstations Ade
- Weerstations Alecto
- Weerstations Ascot
- Weerstations Auriol
- Weerstations Brigmton
- Weerstations Denver
- Weerstations Eurochron
- Weerstations Hama
- Weerstations Hyundai
- Weerstations Irox
- Weerstations La Crosse
- Weerstations Livoo
- Weerstations Meade
- Weerstations Nedis
- Weerstations Techno Line
- Weerstations Technoline
- Weerstations TFA
- Weerstations UPM
- Weerstations Ventus
- Weerstations Viking
- Weerstations Oregon
- Weerstations Clas Ohlson
- Weerstations GoGEN
- Weerstations Steren
- Weerstations Conrad
- Weerstations EMOS
- Weerstations Cotech
- Weerstations Cresta
- Weerstations Prologue
- Weerstations Trevi
- Weerstations Kemot
- Weerstations AcuRite
Nieuwste handleidingen voor Weerstations
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022