Kenmore 9970 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Kenmore 9970 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 162 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Cartridge
Holder
About the Kenmore® 46-9970 water filter cartridge
To reduce the risk associated with choking, do not allow children under 3 years of age to have access to small parts during the
installation of this product. The disposable filter cartridge should be replaced every 6 months at the rated capacity, or sooner if a noticeable
reduction in flow rate occurs.
* By texting the keyword you agree to receive back up to two autodailed marketing messages from us and also agree to our Terms and Conditions
and Privacy Policy at www.shcterms.con/mobile. Message & date rates may apply. Consent is not a condition of any purchase.
WARNING
Water filter cartridge
The water filter cartridge is located in the back upper right corner
of the refrigerator compartment.
When to replace the filter on models
with a replacement indicator light
There is a replacement indicator light for the water filter cartridge
on the dispenser. This light will turn orange to tell you that you need
to replace the filter soon.
The filter cartridge should be replaced when the replacement
indicator light turns red or if the flow of water to the dispenser
or icemaker decreases.
When to replace the filter on models
without a replacement indicator light
The filter cartridge should be replaced every or earlier six months
if the flow of water to the dispenser or icemaker decreases.
Removing the filter cartridge
If you are replacing the cartridge, first remove the old one by
slowly turning it to the left. Do not pull down on the cartridge.
A small amount of water may drip down.
CAUTION: To reduce the risk associated with property damage
due to water leakage, read and follow instructions before installation
and use of this system. Installation and use MUST comply with all state
and local plumbing codes.
Installing the filter cartridge
1 Fill the replacement cartridge with water from the tap to allow
for better flow from the dispenser immediately after installation.
2
Line up the arrow on the cartridge and the cartridge holder.
Place the top of the new cartridge up inside the holder.
Do not push it up into the holder.
3 Slowly turn it to the right until the filter cartridge
stops. DO NOT OVERTIGHTEN. As you turn
the cartridge, it will automatically raise itself into
position. The cartridge will move about a ½ turn.
4 Run water from the dispenser for 1-1/2 gallons
(about three minutes) to clear the system and prevent sputtering.
5 Press and hold the RESET WATER FILTER pad (on some models)
on the dispenser for three seconds.
NOTE: A newly installed water filter cartridge may cause water
to spurt from the dispenser.
Filter bypass plug
You must use the filter bypass plug when a replacement filter cartridge
is not available. The dispenser and the icemaker will not operate without
the filter or filter bypass plug.
To use the filter bypass plug on Water by Culliganâ„¢ models, you must first
remove the filter adaptor from the cartridge holder by turning it to the left.
SmartWater
Filter Bypass
Plug
Filter Bypass
Plug
Water by Culligan
Performance Data Sheet
Kenmore® 46-9970
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the
reduction of substances listed below.
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (21.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary.
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before and after the system. Systems certied for cyst reduction
may be used on disinfected water that may contain lterable cysts. EPA Establishment Number
10350-MN-005.
NOTICE
To reduce the risk associated with property damage due to water leakage:
• Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure exceeds 80 psi,
you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain
how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how
to check for this condition.
• Do not install on hot water supply lines. The maximum operating water temperature of this lter
system is 100º F (38º C).
• Protect lter from freezing. Drain lter when temperatures drop
below 33ºF (0.6ºC).
• The disposable lter cartridge must be replaced every months at the 6
rated capacity, or sooner if a noticeable reduction in î™°ow rate occurs.
For conditions of use, health claims certified by the California Department of Public Health, and
replacements, see performance data sheet. California Department of Public Health Certification
#05-1698. The contaminants or other substances removed or reduced by this water filter are not
necessarily in all users’ water.
Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.
Substance Tested
for Reduction Average Inî™°uent
NSF specied
Challenge Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduc-
tion
Requirements
NSF
Test Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.5% 0.05 mg/L N/A J-00077703≥ 50%
Nominal Particulate Class I, ,
≥0.5 to < 1.0 µm 7,833,333 pts/mL At least 10,000 particles/mL 99.7% 18,617 pts/mL N/A J-00077704≥85%
Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A J-00100036≥99.95%
Asbestos 47 MF/L
107 to 108 bers/L; bers
greater than 10 µm in length <1 MF/L ≥99%>99% N/A J-00077707
Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.5% 0.0005 mg/L 0.003 mg/L N/A J-00077708
Benzene 0.016 mg/L 0.015 mg/L ± 10%± 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00077717
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.7% 0.001 mg/L 0.04 mg/L N/A J-00077718
Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L 0.002 mg/L N/A J-00100039
Lead @ pH 6.5 0.152 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077722
Lead @ pH 8.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077723
Lindane 0.002 mg/L 0.002 mg/L ± 10% 99.0% 0.00002 mg/L 0.0002 mg/L N/A J-00077726
Mercury @ pH 6.5 0.0058 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00100037
Mercury @ pH 8.5 0.0061 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00092355
P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00077729
Tetrachloroethylene 0.015 mg/L 0.015 mg/L ± 10% 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00082184
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-00077730
2,4-D 0.218 mg/L 0.210 mg/L ± 10% 99.5% 0.0009 mg/L 0.07 mg/L N/A J-00085470
*Based on the use of Cryptosporidium parvum oocysts.
Tested and certied by NSF International
against NSF/ANSI Standard 42 and
Standard 53 in model GE PLWF for the
reduction of the claims specied on the
performance data sheet.
REPLACEMENT
ELEMENT
State of California Depart nt of P lic Health me ub
Water Treatment Device
Certificate Number
05- 98 16
Date Issued: February 2,2010
Modified June 25, 2013
Trademark/Model Designation Replacement Ele nts me
GE MWF MWF
PLWF
Ma facturer: Gen al Electric Company nu er
The water treatment devic s) sted on this certificate have met the testing requirements pursuant to e( li
Section 116830 of the Health and Safety Code for the fo owing health related contaminants: ll
Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants
Cysts Asbestos
Lead
Mercury
Organic Contaminants
Carbofuran
Endrin
p-Dichlorobenzene
Benzene
Atrazine
Lindane
Tetrachloroethylene
Toxaphene
2,4- D
Rated S vice Capacity 300 gallons Rated S vice Flow: 0.5 gallons p minute er er er
Conditions of Certification
Do not use wh wa is microbiologically unsafe or with wa of un own quality, ex pt at systems ere ter ter kn ce th
for cyst re ction may be used on disinf ted wa s that contain filterable cysts. du ec ter


Product specificaties

Merk: Kenmore
Categorie: Niet gecategoriseerd
Model: 9970

Heb je hulp nodig?

Als je hulp nodig hebt met Kenmore 9970 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Kenmore

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd