HQ SEC-SA301RF Handleiding

HQ Rookmelder SEC-SA301RF

Lees hieronder de 📖 handleiding in het Nederlandse voor HQ SEC-SA301RF (37 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 53 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/37
Français Nederlands Italiano Español Magyar Suomi Svenska Česky Română Ελληνικά
DeutschEnglish
1
SEC-SA301RF
MANUAL (p. 2)
Oprical Wireless Smokealarm
MODE D’EMPLOI (p. 8)
Détecteur de fumée optique sans l
MANUALE (p. 14)
Allarme Antifumo Ottico Senza li
BRUKSANVISNING (s. 26)
Ασύρματος Οπτικός συναγερμός
Καπνού
MANUAL DE UTILIZARE (p. 32)
Alarmă de fum optică fără cablu
HASZNÁLATI ÚTMUTATÓ (o. 20.)
Vezeték nélküli, optikai füstérzékelő
riasztó
KÄYTTÖOHJE (s. 23)
Langaton optinen palohälytin
ANLEITUNG (s. 5)
Optischer kabelloser Rauchmelder
GEBRUIKSAANWIJZING (p. 11)
Optische draadloze rookmelder
MANUAL DE USO (p. 17)
Alarma óptica inambrica de humos
NÁVOD K POUŽITÍ (s. 29)
Optický bezdrátový detektor kouře
ΕΓΧΕΙΡΙΔΙΟ XPHΣHΣ (σελ. 35)
Ασύρματος Οπτικός συναγερμός
Καπνού
EnglishDeutsch
FrançaisNederlandsItalianoEspañolMagyarSuomiSvenskaČeskyRomânăΕλληνικά
2
ENGLISH
The photoelectric wireless online smoke alarm KD-101LF can be interconnected as a system. Its
communication is very easy just through a LERN-IN button. In a learnable wireless online smoke alarm
system others will sound together if one smoke alarm detects the smoke and sounds. In this way the
alarm is set off.
The product is used in family homes and non-smoking areas.
• TESTING
1. Insert 9V battery and 3 x 1.5V battery (according to Figure).
2. The RED alarm LED will ash about every 40s in working condition (see Figure).
3. Press the TEST button for several seconds, the Red alarm LED and the LEARN-IN (red and green)
LED will ash, then the smoke alarm sounds. It shows that the smoke alarm is in working condition
(see Figure).
9V battery
1.5V x 3
battery
Horn
LEARN-IN LED
(Red or Green)
Alarm LED
(Red)
Test button LEARN-IN
button
• LEARN-IN
SET the MAIN detector/Assistant detector
1. After TESTING, please LEARN-IN the wireless online smoke alarms into a system. Press the
LEARN-IN button each time, the LEARN-IN LED changes in from red to green.
2. MAIN Detector: ensure the LED (main detector) of the LEARN-IN button is GREEN.
3. ASSISTANT Detector: ensure that the LED of the others (assistant detectors) are RED.
4. LEARN-IN Operation: Press the test button of the MAIN detector for several seconds in order to send
out the signal to the assistant detectors; in this case the RED alarm LED ashes and the detector
sounds, while the assistant detectors receive the signal and sound together. Then press the test
button on each assistant detector for several seconds in order to send out the signal to the MAIN
detector. The MAIN detector receives the signal and sounds the alarm.
• INSTALLATION
1. Use supplied screws to install the smoke alarm according to the Figures below.
2. Use the two screws (supplied) to x the mounting plate at the ceiling.
3. Adjust the hook of the mounting plate with the hole of the detector and turn counter-clockwise.
9V battery
installation
1.5V battery
installation
Screw
hole
Screw hole
Hole Hole Hook
Hook
Français Nederlands Italiano Español Magyar Suomi Svenska Česky Română Ελληνικά
DeutschEnglish
3
• Technical Parameters
Operating voltage: DC9V (smoke testing)
DC4.5V (transmission/Receiver: 3 x 1.5V battery)
Current: DC9V average stand-by current ≤10uA
DC9V average alarm current ≤ 20mA
DC4.5V average working current ≤120 uA
Alarm volume: 85dB/3m
Alarm LED: Red LED
LEARN-IN LED: Red/Green LED
Frequency: 433.92MHz
Transmission/Receiver distance: ≤60 m
Operating temperature: -10°C~40°C
• Points for attention:
1. No replaceable parts inside. Only battery is replaceable.
2. Do not use the product in the humid, dusty and smoky environment.
3. When the battery reaches a low energy level, the detector will sound about every 45 seconds to
indicate that the battery must be replaced.
4. Please test the smoke alarm weekly.
• Quality Guarantee:
1. This product is guaranteed for two years by the manufacturer.
2. Repair by third parties or improper operation of the product are excluded from the guarantee.
Declaration of conformity
We,
Nedis B.V., De Tweeling 28, 5215MC ’s-Hertogenbosch, The Netherlands
Tel.: 0031 73 599 1055, Email: info@nedis.com
Declare that product:
Brand: HQ / SEC-SA301RF
Model: KD-101LD
Description: Optical Wireless Smoke alarm
Is in conformity with the following standards:
EN 14604: 2005, EN 300 220-2 V2.1.2, EN 301 489-01 V1.6.1, EN 301 489-03 V1.4.1
And complies with the requirements of the European Union Directives 89/106/EEC and 1999/5/EC.
‘s-Hertogenbosch, 01-09-2009
Mrs. J. Gilad
Purchase director


Product specificaties

Merk: HQ
Categorie: Rookmelder
Model: SEC-SA301RF
Kleur van het product: Wit
Gewicht verpakking: 334 g
Stroombron: Batterij/Accu
Connectiviteitstechnologie: Draadloos
Afmetingen verpakking (BxDxH): 135 x 190 x 60 mm
Ondersteund aantal accu's/batterijen: 4
Certificering: EN 14604
Batterij bijna leeg-indicatie: Ja
Maximumbereik: 3 m
Detector type: Optische detector
Koppelbaar: Ja
Bandbreedte: 433.92 MHz
Bedrijfstemperatuur (T-T): -10 - 40 °C
Alarm decibels: 85 dB

Heb je hulp nodig?

Als je hulp nodig hebt met HQ SEC-SA301RF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder HQ

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Cordes

Cordes CC-4100 Handleiding

18 November 2024
Cordes

Cordes CC-3000 Handleiding

18 November 2024
Cordes

Cordes CC-500 Handleiding

18 November 2024
Nexa

Nexa KD-134A Handleiding

18 November 2024
Gloria

Gloria R-5 Handleiding

16 November 2024
Kidde

Kidde 29HD Handleiding

16 November 2024
Kidde

Kidde 3SFWR Handleiding

24 September 2024