Genelec 7360A Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Genelec 7360A (8 pagina's) in de categorie Monitor. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Genelec 7360A and 7370A
Smart Active Subwoofers
Operating Manual
7300 Series
750-7360A/7370A
Genelec 7360A and 7370A Smart Active Subwoofers
Introduction
Congratulations and a thank-you for the
purchase of this Genelec 7300 series
subwoofer. This manual addresses setting
up and using the Genelec 7360A and 7370A
subwoofers. These subwoofers are designed
to integrate easily into all environments, both
those using analog audio as well as those
using digital AES/EBU audio. Genelec 7360A
and 7370A subwoofers are designed for
precise monitoring of multichannel analog
audio signals and stereo AES/EBU signals.
Multichannel AES/EBU signal can be
monitored by using the 9301 multichannel
digital audio interface device connected to
the subwoofer.
Energy saving Intelligent Signal Sensing
(ISS) can be turned on to put the subwoofer
automatically into a standby state when
audio signal has been absent for a selected
time. In the standby mode the product
consumes less than one Watt of power.
Upon sensing an input signal the subwoofer
automatically wakes up to full operation.
The wait until entering the ISS power save
can be congured using the GLM software.
When the ISS is active you can have your
monitoring system ready for action at all
times.
Installation
Each subwoofer is supplied with a mains
cable, one 5 m GLM network cable, mains
cable, and an operating manual. Before
connecting switch the subwoofer and
monitors oξ‰ˆ.
Connections
Seven balanced XLR input/output pairs
are available for analog signals (see Figure
1). There is a dedicated LFE In and LFE
Out. The connectors Link In and Link Out
can be used to for daisy-chaining multiple
subwoofers with minimum cable count. In
addition to these analog signal connectors,
digital audio in and out connectors
supporting AES/EBU format are available.
The digital out connector can be used to
daisy chain multiple subwoofers while digital
audio is being used.
Multichannel AES/EBU signal can be
monitored by using the 9301 multichannel
digital audio interface device connected to
the subwoofer.
Two CAT5 (RJ45 ) GLM Ne twork
connectors are available for computer
control using the Genelec Loudspeaker
Manager (GLM) software.
Bypass connector supports a ΒΌ in
jack switch-operated subwoofer bass
management bypass function when the xed
85 Hz subwoofer crossover is used.
The mains input supports a wide mains
voltage range (100-240 VAC, 50-60 Hz)
and enables the subwoofer to be plugged
in anywhere globally. If the mains power is
provided with a generator, inverter or certain
lower-quality UPS devices, we recommend
filtering of the mains power voltage
harmonics and taking care that the voltage
supply is stable.
Bass Management
Bass management splits the signal from
each input into low and high frequency
components. Signal content below the
crossover frequency is reproduced by the
subwoofer and signal content above the
crossover frequency is reproduced by the
monitors connected to the outputs of the
subwoofer.
The 7360A and 7370A offer two bass
management methods:
Centralized bass management
This method builds both the highpass and
the lowpass lters in the subwoofer and can
be used in all setups, with or without GLM
control. A xed 85 Hz crossover lter for the
analog main channels is default for manual
use.
In this method all analog signal cables
are routed through the subwoofer's IN/
OUT connectors to the respective main
monitor
s.
Distributed bass management
In this method the lowpass lter is applied
in the subwoofer and the highpass lter in
the monitor, and these are set in synchrony
using the GLM control network. This method
is only available in systems where GLM is
used.
The GLM software enables adjusting the
subwoofer/monitor crossover from 50 Hz to
100 Hz when distributed bass management
is used.
The distributed bass management
supports three different signal cabling
congurations:
β€’ All channels routed through the
subwoofer's IN/OUT connectors to the
respective monitors.
β€’ Y-cables from the source to the
subwoofer's IN connector and the
monitor's signal input.
β€’ Signal sources with dual outputs for each
channel.
Using With GLMβ„’
Control Network
Subwoofers are fully compatible with
Genelec Loudspeaker Manager GLMβ„’ and
the proprietary Genelec monitor control
network and Genelec SAM monitors. Using
the GLM control method unleashes the full
room compensation power in the subwoofer,
with 20 parametric room compensation
lters. This level of room compensation detail
is only available when the GLM is used. Use
with the GLMβ„’ network is described in the
DSP System Operating Manual.
System setup
Although the subwoofer can be used without
the GLMβ„’ software and control network,
they only reach their full potential when
set up and calibrated using the GLMβ„’
software. Genelec Loudspeaker Manager
GLMβ„’ and the proprietary Genelec
monitor control network offer automated
acoustic equalization and alignment for any
reproduction system from simple stereo to
very complex 3D immersive setups including
also one or more subwoofers. GLM setup is
fast and accurate and can precisely address
the typical narrow-band low frequency mode
resonances of a room. The settings can be
controlled with a computer or be permanently
stored in the monitors to make the setup
available at all times even when a computer
is not in use. Genelec recommends setting
up SAM monitoring systems using GLM. You
can nd a detailed description of the setup
and the use of GLMβ„’ in the GLMβ„’ System
Operating Manual.
Figure 1. Connector panel
of the 7360A. The 7370A
is similar.
Figure 2. GLM Network cabling. Audio cabling not shown.
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM TERMINA RT O
COMPUTER
RUNNING
GLM SOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
SUBWOOFER
The setup is fast and consists of the
following steps:
β€’ Connect a CAT5 (RJ45) cable between
each monitor (and subwoofer) and nally
to the control network input of the GLM
Adapter device (see Figure 1).
β€’ Connect the GLM Adapter device to
computer USB connector.
β€’ Using a microphone stand, place the
Genelec measurement microphone at the
listening location with the microphone
pointing upwards and the microphone
top at the height of the engineer’s ear.
The microphone is a part of the GLM
User Kit.
β€’ Connect the microphone cable to the
microphone input in the GLM Adapter
device.
β€’ Download the GLM software at the
Genelec web site (www.genelec.com).
β€’ Install the GLM software and follow the
instructions in the software to measure
and set up your system.
β€’ If you plan to not use a computer for
controlling the monitors, use the GLM
software to write the setting into the
monitors (use menu item β€œStore | Store
the Current Group Settings…”).
While the GLM network is disconnected
the settings stored using the Genelec
Loudspeaker Manager software can be
selected in use by setting the STORED
switch ON.
Using Without GLM
Cabling
The 7300 series subwoofers can be easily set
up using the xed 85 Hz analogue crossover
filter. This fixed crossover filter is on as
a factory setting and highpass filters the
analogue outputs on the subwoofer. When
using this method, run each signal cable rst
to the subwoofer. Then, run the respective
output to the monitor. This monitor feed
signal is highpass ltered at 85 Hz.
When using the LFE signal, run the LFE
signal to the subwoofer LFE in connector.
W h e n d a i s y - c h a i n i n g m u l t i p l e
subwoofers, run a cable from the Link Out
connector the next subwoofer’s Link In
IN 3 IN 4OUT 3 OUT 4 IN 5 OUT 5
IN 6 IN 7
OUT 6 OUT 7 LFE IN LFE OUT
LINK OUT
LINK IN
OUT 2IN 1 IN 2OUT 1
TEST 1 TEST 2
GLM NETWORK
ANALOGANALOGANALOG
SERIAL
NUMBER
RESET FACTORYTO
SETTINGS: PUSH
BUTT ON FOR 10 SEC
MAINS INPUT
50 / 6 0 Hz 300 W
10 240 V~0 -
-4
0
+2
-2 -6
+4 +12
+8
PHASE
LFE +10 dB
STORED
ISS
TEST T ONE
A/B
DIGITAL LFE
-20 dB
-10 dB
LEVEL
BASS ROLL-OFF
BYPASS
ON/OFF
LFE CHANNEL
7360A SMART ACTIVE SUBWOOFER
WARNING
ELECTR IC SHOC K HAZARD . DO
NOT OPEN. DO NOT SUBJ ECT
TO WATER OR MOISTURE. NO
USER SERVICEABLE SPART
INSIDE. REFER SER VICING TO
QUA LIFIED PERSONNE L. USE
EARTHED MAINS CONNEC TION
ONLY.
THIS DEVICE COMPLIES
WITH FC C PAR T 1 5 AND
CANAD IAN ICES-003 RADIO
FREQU ENCY CLASS B E MISSION
REQ UIREMENTS. REFER TO
OPERATING MANUAL FOR FULL
INFORMATION.
LAITE ON LIITETTΓ„VΓ„ SUOJAKOSKETTIMILL A
VARUSTETTUUN PISTORASIAAN.
APPARATETMΓ… TILKOPLES JORDET STIKKONTAKT.
APPARATENSKAL L ANSLU TAS TILL JORD AT UTTAG.
RISQU E D E CHOC Γ‰L ECTRIQUE. NE S OUVRIR. NE SPA PA
EXPOSER À L 'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À
L'INTÉRIEUR R EMPLAÇABLE PAR L 'UTILISATEU R.ADRESSER
TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ.
CET APPAREILDOIT ÊTRE RACC ORDΓ‰ Γ€ LA TERRE.
AVERTISSEMENT
MADE IN FINLAND
www.genelec.com
ON O FF
-90Β°
-180Β°
-4 dB
-8 dB
INPUT dBu
100 dB SPL (1 m)
PRODUCING
DIGI LTA
OUT IN
AES/EBU IN/OUT
CONNECTORS
GLM NETWORK
CONNECTORS
ANALOG
IN/OUT
CONNECTORS
POWER
SWITCH
MAINS
INPUT
ROTARY
LEVEL
ADJUSTMENT
CONTROL
SWITCHES
BYPASS
SWITCH
CONNECTOR


Product specificaties

Merk: Genelec
Categorie: Monitor
Model: 7360A

Heb je hulp nodig?

Als je hulp nodig hebt met Genelec 7360A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Monitor Genelec

Handleiding Monitor

Nieuwste handleidingen voor Monitor