Genelec 7370A Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Genelec 7370A (8 pagina's) in de categorie Monitor. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Genelec 7360A and 7370A
Smart Active Subwoofers
Operating Manual
7300 Series
750-7360A/7370A
Genelec 7360A and 7370A Smart Active Subwoofers
Introduction
Congratulations and a thank-you for the
purchase of this Genelec 7300 series
subwoofer. This manual addresses setting
up and using the Genelec 7360A and 7370A
subwoofers. These subwoofers are designed
to integrate easily into all environments, both
those using analogue audio as well as those
using digital AES/EBU audio. Genelec 7360A
and 7370A subwoofers are designed for
precise monitoring of multichannel analogue
audio signals and stereo AES/EBU signals.
Multichannel AES/EBU signal can be
monitored by using the 9301A multichannel
digital audio interface device connected to
the subwoofer.
Energy saving Intelligent Signal Sensing
(ISS) can be turned on to put the subwoofer
automatically into a standby state when
audio signal has been absent for a selected
time. In the standby mode the product
consumes less than one Watt of power.
Upon sensing an input signal the subwoofer
automatically wakes up to full operation. The
wait until entering the ISS power save can be
congured using the Genelec Loudspeaker
Manager (GLM) software. When the ISS is
active you can have your monitoring system
ready for action at all times.
Installation
Each subwoofer is supplied with a mains
cable, one 5 m GLM network cable and an
operating manual. Before connecting switch
the subwoofer and monitors oξ‰ˆ.
Connections
Analogue input 1 thru 7
XLR balanced inputs, typically provided from
console or monitor controller. +24 dBu max.
Multichannel digital signal can be
monitored by using the 9301A AES/EBU
Multichannel Interface device connected to
the subwoofer.
LFE In
This is a dedicated input for LFE use with
analogue signals. Its bandwidth is extended
to 150 Hz. The addition of +10 dB is enabled
by the +10 dB DIP Switch.
Analogue Output 1 thru 7
Balanced XLR connectors for connecting the
main monitors to the subwoofer. Depending
on the chosen mode of bass management,
these outputs may carry either unltered or
high-pass ltered signal to the main monitors.
See chapter "Bass Management" for details.
LFE Out
Straight thru-put of the LFE In. Typically LFE
Out will be connected to LFE In when daisy-
chaining multiple subwoofers.
Link Out
Combined summation of main inputs 1 thru
7 that are passed along to a second or more
daisy-chained subwoofers. See chapter
"Using Multiple Subwoofers."
Link In
Use this input when daisy-chaining
subwoofers. Accepts ONLY the signal from
Link Out. Analogue inputs 1-7 should not be
used when Link In is connected. See chapter
"Using Multiple Subwoofers."
OUT1 / Test 1
Passes the 85 Hz Phase Test Tone when used
in the Stand Alone Manual Mode. Enabled
with the Dip Switch labeled "Test Tone".
OUT2/Test 2
Reserved for future use.
AES/EBU IN
Two channel AES/EBU digital input. This
input can also be congured to receive a
digital LFE channel using the GLM software
or the "Digital LFE" and "LFE Channel A/B"
switches.
AES/EBU OUT
Output is straight thru-put of AES/EBU IN.
BYPASS
Bass manager subwoofer Bypass. For use
with Stand-alone Manual mode. Accepts a
TRS/TS contact open/close device.
GLM NETWORK
Two CAT5 (RJ45) GLM Network connectors
for computer control using the Genelec
Loudspeaker Manager (GLM) software.
MAINS INPUT
Supports a wide mains voltage range
(100-240 VAC, 50-60 Hz) and enables the
subwoofer to be plugged in anywhere
globally. If the mains power is provided with
a generator, inverter or certain lower-quality
UPS devices, we recommend ltering of the
mains power voltage harmonics and taking
care that the voltage supply is stable.
Bass Management
Bass management splits the signal from each
input into low and high frequency components.
Signal content below the crossover frequency
is reproduced by the subwoofer and signal
content above the crossover frequency is
reproduced by the monitors connected to the
outputs of the subwoofer.
The 736
0A and 7370A offer two bass
management methods:
Centralized bass management
This method builds both the highpass and
the lowpass lters in the subwoofer and can
be used in all setups, with or without GLM
control. A xed 85 Hz crossover lter for the
analogue main channels is default for manual
stand-alone use. However, we recommend
the use of the much more ξƒ…exible distributed
bass management method.
In this method all analogue signal cables
are routed through the subwoofer's IN/OUT
connectors to the respective main monitors.
Distributed bass management
In this method the lowpass lter is applied
in the subwoofer and the highpass lter in
the monitor, and these are set in synchrony
using the GLM network. This method is only
available in systems where GLM is used.
The GLM management software enables
adjusting the subwoofer/monitor crossover
from 50 Hz to 100 Hz when distributed bass
management is used.
The distributed bass management
supports three different signal cabling
congurations:
β€’ All channels routed through the
subwoofer's IN/OUT connectors to the
respective monitors.
Figure 1. Connector panel
of the 7360A. The 7370A
is similar.
Figure 2. GLM Network cabling. Audio cabling not shown.
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM TERMINA RT O
COMPUTER
RUNNING
GLM SOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
SUBWOOFER
β€’ Y-cables from the source to the
subwoofer's IN connector and the
monitor's signal input.
β€’ Signal sources with dual outputs for each
channel.
Use With GLMβ„’
Control Network
Subwoofers are fully compatible with
Genelec Loudspeaker Manager GLMβ„’ and
the proprietary Genelec monitor control
network and Genelec SAM monitors. Using
the GLM control method unleashes the full
room compensation power in the subwoofer,
with 20 parametric room compensation
lters. This level of room compensation detail
is only available when the GLM is used. Use
with the GLMβ„’ network is described in the
GLM System Operating Manual.
System setup
Although the subwoofer can be used without
the GLMβ„’ software and control network,
they only reach their full potential when
set up and calibrated using the GLMβ„’
software. Genelec Loudspeaker Manager
GLMβ„’ and the proprietary Genelec
monitor control network offer automated
acoustic equalization and alignment for any
reproduction system from simple stereo to
very complex 3D immersive setups including
also one or more subwoofers. GLM setup is
fast and accurate and can precisely address
the typical narrow-band low frequency mode
resonances of a room, or typical radiation
load frequency response compensation. The
settings can be controlled with a computer
or be permanently stored in the monitors to
make the setup available at all times even
when a computer is not in use. Genelec
recommends setting up SAM monitoring
systems using GLM. You can nd a detailed
description of the setup and the use of
GLMβ„’ in the GLMβ„’ System Operating
Manual.
The setup is fast and consists of the
following steps:
β€’ Connect a CAT5 (RJ45) cable between
each monitor (and subwoofer) and nally
to the control network input of the GLM
Adapter device (see Figure 1).
β€’ Connect the GLM Adapter device to
computer USB connector.
β€’ Using a microphone stand, place the
Genelec measurement microphone at the
listening location with the microphone
IN 3 IN 4OUT 3 OUT 4 IN 5 OUT 5
IN 6 IN 7
OUT 6 OUT 7 LFE IN LFE OUT
LINK OUT
LINK IN
OUT 2IN 1 IN 2OUT 1
TEST 1 TEST 2
GLM NETWORK
ANALOGANALOGANALOG
SERIAL
NUMBER
RESET FACTORYTO
SETTINGS: PUSH
BUTT ON FOR 10 SEC
MAINS INPUT
50 / 6 0 Hz 300 W
10 240 V~0 -
-4
0
+2
-2 -6
+4 +12
+8
PHASE
LFE +10 dB
STORED
ISS
TEST T ONE
A/B
DIGITAL LFE
-20 dB
-10 dB
LEVEL
BASS ROLL-OFF
BYPASS
ON/OFF
LFE CHANNEL
7360A SMART ACTIVE SUBWOOFER
WARNING
ELECTR IC SHOC K HAZARD . DO
NOT OPEN. DO NOT SUBJ ECT
TO WATER OR MOISTURE. NO
USER SERVICEABLE SPART
INSIDE. REFER SER VICING TO
QUA LIFIED PERSONNE L. USE
EARTHED MAINS CONNEC TION
ONLY.
THIS DEVICE COMPLIES
WITH FC C PAR T 1 5 AND
CANAD IAN ICES-003 RADIO
FREQU ENCY CLASS B E MISSION
REQ UIREMENTS. REFER TO
OPERATING MANUAL FOR FULL
INFORMATION.
LAITE ON LIITETTΓ„VΓ„ SUOJAKOSKETTIMILL A
VARUSTETTUUN PISTORASIAAN.
APPARATETMΓ… TILKOPLES JORDET STIKKONTAKT.
APPARATENSKAL L ANSLU TAS TILL JORD AT UTTAG.
RISQU E D E CHOC Γ‰L ECTRIQUE. NE S OUVRIR. NE SPA PA
EXPOSER À L 'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À
L'INTÉRIEUR R EMPLAÇABLE PAR L 'UTILISATEU R.ADRESSER
TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ.
CET APPAREILDOIT ÊTRE RACC ORDΓ‰ Γ€ L ATERRE.
AVERTISSEMENT
MADE IN FINLAND
www.genelec.com
ON O FF
-90Β°
-180Β°
-4 dB
-8 dB
INPUT dBu
100 dB S PL (1 m)
PRODUCING
DIGI LTA
OUT IN
AES/EBU IN/OUT
CONNECTORS
GLM NETWORK
CONNECTORS
ANALOG
IN/OUT
CONNECTORS
POWER
SWITCH
MAINS
INPUT
ROTARY
LEVEL
ADJUSTMENT
CONTROL
SWITCHES
BYPASS
SWITCH
CONNECTOR


Product specificaties

Merk: Genelec
Categorie: Monitor
Model: 7370A

Heb je hulp nodig?

Als je hulp nodig hebt met Genelec 7370A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Monitor Genelec

Handleiding Monitor

Nieuwste handleidingen voor Monitor