The Fredenstein Bento 2 is a high performance two module carrier for Fredenstein Series 600
modules or API-500 compatible plug-in cards. The unit can accept a maximum of 2 modules.
The Bento 2 features several important upgrades compared with third party products:
Universal power supply: Mains voltages range from 90V AC to 240V AC, 50 to 60 Hz.
Increased output currents: +-16V DC 0.9A and +48V DC 0.033A
Additional TRS inputs and outputs, parallel to the XLR connectors.
Built-in Audio Routing: Slot 1 can be daisy-chained to slot 2 by simply flipping a switch on the
back-panel.
Compressor buss linking: Compressor modules can be linked by engaging a switch on the back-
panel as well.
Secondary power-switch and voltage indicators on the front-panel.
Installation:
Electrical Safety Warnings:
Do not open the enclosure, hazardous voltages are present inside!
There are no user serviceable parts inside.
Always disconnect the mains cord before installing or removing modules!
If you need to replace the mains fuse, make sure the replacement has the same
rating (0.5AT 250V).
Please disconnect the mains from your Bento 2 before installing or removing modules. Make sure
each installed module is well seated in the receiving connector and the module is secured by fasten
the two mounting screws.
Front View:
Fredenstein Bento 2 Manual V1.1 July 18, 2014 Page 1
Fredenstein Bento 2 Module Carrier
Operation:
After installation of the modules connect the mains cord to the Bento 2 IEC socket located on the
back-panel and than connect the mains cable to a grounded outlet. Now turn the Bento 2 on by
operating the I/O switch (also part of the IEC socket on the back), then turn the secondary power-
switch on the front-panel on and the three LEDs next to it will come on within 5 seconds and the
Bento 2 is ready for use. To connect the audio signals you have a choice of using either the XLR or
TRS connector on the inputs. If your 500 series modules support low load impedances, it might be
acceptable to use the output XLR and TRS connectors simultaneously.
In case you want, for example, route the audio signal from a mic-pre in slot 1 to a EQ in slot 2
simply turn on the audio link switch located on the back-panel. (Please be aware that this disables
the slot 2 XLR and TRS input connectors). Slot 1 input will be the microphone input and the slot 2
output will be the audio output of the complete chain.
In case you are using multiple compressors which make use of the compressor link buss (Pin 6),
you can link the two slots by putting the buss switch in the I position. If you are using different
types of compressors, you must keep the comp buss switch off.
Rear View:
Specifications:
Input Voltage: 90V AC to 240V AC, 50 to 60 Hz
Output Voltages: +16V DC 0.9A
-16V DC 0.9A
+48V DC 0.033A
Power Consumption: max 35W
Dimension (LxHxD): 480mm x 50mm x 190mm
Weight: 2.0kg(NW)
Fredenstein Bento 2 Manual V1.1 July 18, 2014 Page 2


Product specificaties

Merk: Fredenstein
Categorie: Niet gecategoriseerd
Model: Bento 2

Heb je hulp nodig?

Als je hulp nodig hebt met Fredenstein Bento 2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fredenstein

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd