093001-02-21-22-24 en ma 2012
Longlife HEAT SHADE
Food warming luminaire specifi cation and installation
instructions for:
L593 - popular . Gantry fi tting
L596 - bell - Gantry fi tting
L597 - ceiling suspension
L598 - rise and fall·- ceiling suspension
GENERAL INFORMATION
Please read these instructions carefully. They will help you get the best out of your new LONGLIFE HEATSHADE and should
be kept for your reference.
The LONGLIFE HEATSHADE is designed for use with any Edison screw Infra-Red (Hard Glass) heat lamp and is essential
for maintaining the heat of servery food. The warming beam is directed to keep an adequate temperature and affording a
pleasing illumination to display the food.
APPLICATIONS
For indoor use only, above hot food displays in:
Hotels, Restaurants, Cafeterias, Canteens, Pub Grub Services.
FEATURES OF THE HEAT LAMP SYSTEM
1. Gives instant direct heat, no warm up period.
2. Provides a penetrating warmth without congealing surfaces of sauces, gravies etc.
3. Simple to install, either singly or in multiple units.
4. Reduces wastage by keeping food and plates warm.
5. Sale in use. Hard glass bulbs are resistant to thermal shock caused by accidental splashing.
MATERIALS AND FINISH
The shades are manufactured from high grade aluminium and electrostatically sprayed with thermoplastic lacquer for high
heat, chemical and water resistance.
Available in the following fi nishes:
Brushed Copper
Brushed Aluminium
Brushed Brass
Brushed Bronze
Gloss Black
Gloss White
All models are fi tted with ceramic Edison screw lamp holders comprising 10 mm all thread nipple assembly and prewired
with heat resistant cable. (NOTE: Reference to Catalogue No. L598, Rise and Fall Heat shade, the upper part of this unit,
the rise and fall mechanism, utilises PVC insulated cable).
Fittings accommodate gantry assembly, ceiling suspension and rise and fall mechanism.
SPECIFICATION
Voltage: 220 - 240 Volts.
Power: 250 Watts.
Frequency: 50 Hertz.
Lamp type: You may use either red or clear tungsten fi lament infrared HARD GLASS 250W lamps only
This appliance is for INDOOR use only.
WARNING: THIS LUMINAIRE IS A CLASS 1 ELECTRICAL PRODUCT AND MUST BE EARTHED.
ELECTRICAL INSTALLATION
WARNING: THE INSTALLATION OF THE HEATSHADE SHOULD BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Installation must follow IEE Wiring Regulations -BS7671 (IEC 364 a related standard) and also instructions attached.
(PLEASE REFER TO YOUR OWN NATIONAL WIRING REGULATIONS).
IMPORTANT: Before commencing installation, service, adjustments or lamp replacement, power to the relevant circuit MUST
BE SWITCHED OFF at the main circuit breaker or fuse panel.
093001-02-21-22-24 en ma 2012
ELECTRICAL CONNECTION
All incoming cable installation should be heat resistant to 100 degrees Celsius.
On no account should the prewired heat resistant cable be replaced with ordinary PVC insulated cable.
All terminal connectors used must be heat resistant to 100 degrees Celsius and shrouded.
Any channels or gantries used MUST BE EARTHED.
The supply wiring must be routed from a fused source through a switch and then to the location you have selected.
If a 13 amp (BS 1363) plug is used a 3 amp fuse must be fi tted, or if any other type of plug is used a 5 amp must be fi t-
ted either in the plug or adaptor or at the Distribution Board.
Ensure all ceiling roses are properly secured alter any height or tension adjustments are made. Do not leave electrical con-
nections exposed.
When stripping sheathing and insulation of cores leave the conductor exposed by approximately 6 mm.
COLOUR CODING OF WIRES
IMPORTANT:
The wires are coloured in accordance with the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
As the colours of the wires in the mains lead of this Luminaire may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the
letter or by the earth symbol E
z
or coloured green, or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter or coloured black.N
The wire which is coloured brown must be connected to the terminal which is marked with the letter or coloured red.L
093001-02-21-22-24 en ma 2012
GENERAL ASSEMBLY INSTRUCTIONS - FOR ALL MODELS
WARNING: THESE LUMINAIRES ARE NOT SUITABLE FOR MOUNTING ON A NORMALLY FLAMMABLE SURFACE.
Please refer to diagrams attached: All models should be mounted so that the base of the shade is 330 mm to 450 mm
above food, (see drawing). For multiple mounting suspend at 450 centres.
L593 and L596 Gantry Models - Main point of fi xing is by means of a 10 mm brass all thread nipple and locknuts supplied.
a) Mark out Heatshades positions and drill clearance holes dia 13.5 mm fi xing holes and deburr sharp edges.
Suitable gantries should measure 50 x 50 mm.
b) Assemblies units ensuring anti-rotation washer, Lock nut, thread reducer and cord grips are positioned correctly (see
diagram attached).
c) Ensure any electrical connections are made in a suitable junction box mounted above the gantry
L593 ANC L596 GANTRY MODELS
GENERAL INSTRUCTIONS
Model L596 (Which consists of items
L5961, L5966, L5964 and L5967) Model L593 (Which consists of items
L5931 , L5933, and L5934)


Product specificaties

Merk: Emga
Categorie: Niet gecategoriseerd
Model: 093025

Heb je hulp nodig?

Als je hulp nodig hebt met Emga 093025 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Emga

Emga

Emga 093025 Handleiding

12 Januari 2024
Emga

Emga 340002 Handleiding

12 Januari 2024
Emga

Emga 093022 Handleiding

12 Januari 2024
Emga

Emga 861085 Handleiding

12 Januari 2024
Emga

Emga 340004 Handleiding

12 Januari 2024
Emga

Emga 861200 Handleiding

1 December 2023
Emga

Emga 093001 Handleiding

1 December 2023
Emga

Emga 093021 Handleiding

1 December 2023
Emga

Emga 340003 Handleiding

1 December 2023
Emga

Emga 115115 Handleiding

1 December 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024