Elektrobock Pocket Home PH-BP1-P9 Handleiding

Elektrobock Receiver Pocket Home PH-BP1-P9

Lees hieronder de 📖 handleiding in het Nederlandse voor Elektrobock Pocket Home PH-BP1-P9 (6 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 60 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
1
BASIC DESCRIPTION
output
R10
output
R9
output
R8
output
R7
output
R1
output
R2
output
R3
output
R4
output
R5
output
R6
input
+5V
Del button
Fce button
PWR diode
R1-R10 diodes
status indication of output
contacts R1-R10
power supply indication
to choose channel R1-R9
antenna with SMA connector
at 433.92 MHz
to delete codes
DIMENSIONS
R1-R10 output contacts are
potential-free (voltage-free)
Max. number of 10 thermo-valves can
be connected to one output
The receiver is able to receive signals
from 9 transmitters (thermostats) at the
most
2
The 9-channel receiver PH-BP1-P9 in connection with the PH-BP1-V transmitters is used for
wireless control of individual rooms (zone control) in a oor heating system. There is no need
to install any connecting cables between the receiver and transmitters (room thermostats)!
The entire set can be included in the PocketHome
® system and all zones controlled from a
single point by means of a central unit and/or through a PC. In that case it is rst necessary
to activate the PH-BP1-V transmitter in the central unit (see the PH-BP1-V manual)! In objects
which do not necessitate central control the assembly can also work autonomously without
a central unit.
FUNCTION
The main function of the receiver is controlling the distributor thermo-valves according to the
requirements received from the corresponding transmitters. The receiver is able to receive
signals from 9 transmitters at the most. If a heating requirement is sent from a cer tain zone, a
relay switches at the pertinent output to control a thermo-valve. Simultaneously, the R10 pump
relay is switched. If all thermo-valves are shut off, the pump switches off automatically.
WIRING DIAGRAM
Power supply +5V:
We recommend using
1) The AD05, +5V/2.5A/DC, for
socket installation
2) AD05-DIN, +5 V/2.5 A/DC
on the DIN-bar
Thermo-valves:
Use thermo-valves of the NC type
(closed without current).
Example: type SEH30.23
Pump:
Connect according to the pump
type in conformity with the
manufacturer’s instructions!
3
INSTALLATION
1) Install the receiver (indoors) as far as possible (at least 0.5 m) from big metal objects and
from power lines to avoid interference of signal reception!
2) The installation must be done in a voltage-free state!
3) We recommend that the installation be done by a person adequately qualifi ed in electrical
engineering!
4) To prevent interference and affection of systems, every system is protected by its unique
code factory-saved in the PH-CJ37 / PHCJ37 Plus central unit (or in the PH-BP1-V
transmitter for autonomous systems)!
5) For correct communication of all elements in the PocketHome
® system with the PH-CJ37
/ PH-CJ37 Plus central unit, the code must be learned – every element added to the
system ACTIVATED!!
6) As the entire system works at two-way radio frequency of 433.92 MHz, follow the
installation and location instructions!
! Caution:
Receiver
Adapted to installation on the DIN bar. The operating voltage is +5 VDC. Connect the
adapter (AD05 for socket installation or AD05-DIN for DIN bar installation) to terminals
0 and +5V. Connect the adapter to 230 VAC.
External antenna
To increase coverage, an external antenna of 433.92 MHz can be used. Disconnect
the antenna supplied as standard and connect the external one to the SMA connector,
and locate the antenna outside the wiring box.
Connection of thermo-valves
The cable is connected to corresponding thermo-valve terminals marked R1 to R9.
Observe the maximum number of thermo-valves connected to a single output. If more
thermo-valves are connected to one output, the individual conductors must be protec-
ted against short circuit (or connected outside the receiver). The R1-R9 outputs are
potential-free, and only the NC-type thermo-valves can be connected to them (closed
without current)!
Pump connection
The R10 output is also potential-free, intended for connecting the pump
(see the diagram).