Elektrobock BT002 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Elektrobock BT002 (2 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 56 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
:LUHOHVVUHFHLYHUIRUFRQWURORIHOHFWULF
KHDWLQJGHYLFHV
:$//02817('
Control of electric heating systems
The connected electric appliance is switched according to the
required temperature
Two-way radio communication at 433,92 MHz
Operating instructions
Version 11.02
BPT002 is suitable for switching heating panels, directheaters,
radiant panels, heating mats, etc. It switches the connected de-
vice according to the information received from the transmitter.
To be installedin internal rooms. Do not locate near power lines!
TECHNICAL PARAMETERS
Power supply 230 V/ 50 Hz
Communication type two-way
Frequency 433,92 MHz
Sensitivity < - 95 dBm
Range 200 m (in free area), 25 m (in built-up area)
Output relay, max.16A/ 250 VAC
Protection IP40
Working temperature 0 to 40°C
Dimensions (LxWxD) 109 mm x 80 mm x 31mm
In case of guarantee or
post-guarantee service, send the
receiver to the manufacturer’s
address.
DECLARATION OF CONFORMITY
We, ELEKTROBOCK CZ s.r.o., herewith declare that our product BPT002 is in conformity
with the basic requirements and other respective provisions of the directive 1999/5/ES.
Issued: 1.04.2012
Pb
LEAD FREE
mit Einkland mit Ro HS
MADE IN CZECH REPUBLIC
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel./fax: +420 541 230 216
www.elbock.cz
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.:
examined by:
date of sale:
stamp of shop:
INSTALLATION
BPT002 is used for switching the heating device in connection with the
appropriate thermostat.
Fig.1 Fig.2 Fig.3
holes for
installationon
KU/KP68
FUNCTION-
BUTTON
output terminals
Wiring diagram: power supply terminals
The device can only be installed by a person with adequate
qualification!
The installation must be executed in a voltage-free state!
ACTIVATION PROCEDURE
INDICATION DIODES
1. Lift off the front cover of the receiver acc. to Fig. 1, 2.
2. Attach the receiver to the wall (or to the wiring box directly).
3. Switch off the main circuit breaker.
4. Connect the receiver acc. to the diagram.
5. Connect the receiver to the mains 230 V / 50 Hz.
6. Switch on the main circuit breaker; the green diode flashes on the
receiver; thus the receiver is ready for further setting.
7. On receiver BPT002 shortly press the FUNCTION BUTTON on for
about 1.5 s the green and red diode are flashing alternately) ( .
8. On the thermostat (transmiter) press the button for sendig the code
to activate the receiver - see to the manual for the given transmitter
(thermostat).
9. If the code has been learned correctly, the green and red diodes flash
simultaneously.
Fig.4 FUNCTION BUTTON (R) :
SHORT PRESS (for about 1.5 s) - for coding.
LONG PRESS (for about 5 s)- RESET deleting the code
from the memory (the green and red LEDsflash simulta-
neously).
LED 1 LED 2 FUNCTION
empty memory, code not learned
code learned
FLASHING ALTERNATELY = code learning mode
FLASHING SIMULTANEOUSLY = code has been learned
SIMULTANEOUS LONG FLASH= code has been ERASED
relay switched
ERROR (if no signal is received from the transmit-ter within
approx. 6 hours, it switches to the 2-min-ON / 8-min-OFF
mode). LED 2 is only flashing ifthe relay is on, i.e. for 2
minutes.
EXPLANATIONS: LIT UNLIT FLASHING


Product specificaties

Merk: Elektrobock
Categorie: Receiver
Model: BT002

Heb je hulp nodig?

Als je hulp nodig hebt met Elektrobock BT002 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Elektrobock

Handleiding Receiver

Nieuwste handleidingen voor Receiver