• IMPORTANT: the control wires are not
insulated from the mains power supply.
All connected equipment must be marked
CE and meet the requirements of the
low voltage devices as well as assembly
recommendations.
Local control wires can be extended
up to 10 m (separate from the 230 V).
• The roller shutter high and low stops must
be set before the receiver is installed.
1 - Installation
1.1 Connection instructions for terminals 1 2 3 4.
- Strip the wires while respecting the strip
length specified on the product.
- Push the wire fully into the terminal.
1.1.1 Solid wires Stranded wires 1.1.2
1.2 Connection instructions for IN1 - COM - IN2 terminals
- Use the wires supplied.
- Push the wire fully into the terminal.
1.3 Connection
- Connect the motor control wires to terminals 3 and 4
(motor lowering control wire to terminal 3, raising control wire to terminal 4).
- Connect the switch to the IN1 - COM - IN2 terminals.
- Connect the 230 V power supply to terminals 1 and 2.
- Switch the installation power back on to continue with the association operation.
2 - Association
3 - Configuration
Configure the receiver according to
the type of switch connected.
Mode 1 (by default): Hold switch
Raise/Stop/Lower
Mode 2: Raise/Lower
double push-button
Raise + Lower: Stop
Mode 3: Raise/Stop/Lower/Stop
push-button
To modify the receiver configuration.
- Press the receiver's button for 6 seconds.
- The LED flashes, then becomes steady, release.
The number of flashes corresponds
to the current mode.
- Briefly press the receiver button to select the mode.
- Confirm the selected mode by pressing the button
for 3 seconds until the LED switches off.
4 - Learning for the shuer travel time
Perform a complete cycle from stop to stop:
1- Lower or raise the roller shutter completely to the stop.
2- Do the reverse action until the opposite stop is reached.
Note:
The learning for the shutter travel time adjusts itself automatically for each complete
cycle from stop to stop.
If the motor has 4 wires (Live/Neutral/Raise/Lower) or if the power of the connected
motor is less than 45 W, or if an electronic motor is fitted (e.g. Hard-wired Tymoov),
Tyxia 5630/5730 cannot perform automatic learning for the shutter travel time.
The receiver or receivers must be configured in “manual learning mode” (see additio-
nal instructions on the Tyxia 5630-5730 pages on the DELTADORE site).
5 - Troubleshooting
Summary of functions accessible using the receiver button:
0,75 - 1,5 mm
Ø
2
2
1
> 6 s
TYXIA
1234
TYXIA
1234
TYXIA
1234
TYXIA
12
EN
Technical characteristics
- Power supply: 230 V~ 0.6 VA
- 2 powered contact outputs: TYXIA 5630 (1 A) - TYXIA 5730 (2 A)
- Stand-by consumption: 0.06 W
- Number of associated transmitters: 16 maximum
- Storage temperature: -10°C/+70°C
- Operating temperature: -10°C/+40°C
- IP 40 (flush mounting box)
- Dimensions: 41 x 36 x 14.5 mm
- X3D wireless remote control device: 868.7 MHz to 869.2 MHz
- Maximum radio power < 10 mW
- Receiver category: 2
EN Receiver
for roller shutter
Use an electrically
isolated tool to perform
the actions on the
receiver configuration
button.
TYXIA
IPx4
230V~
OFF
Switch off the installation
power supply
You can install the receiver for roller shutter
in a flush-mounted box behind a switch or
control push-button or in a sealed box inside
the roller shutter, a safe distance from metal
parts.
Removal recommendations
- Switch off the power supply.
- Use the tool supplied or a 2.5 mm screw-
driver to press the button of the front
terminal before removing the wire. 2
1
Removal recommendations
Turn the wire while pulling on it.
Do not strip the wires when they
are connected to the product as you
could damage the internal connector.
1
2
123 4
2
7mm 0,5 mm
KY31A02
123 4
230 V~
IN1
COM
IN2
1234
TYXIA
1 2 3 4
IN1
COM
IN2
IN1
COM
IN2
IN1
COM
1
2
3
1
2
1
2
Hold switch
Double
push-button
Push
button
Ê
- Press and hold the receiver
button for 3 seconds until the
LED flashes, release.
Ë
On the transmitter:
- Send the association command
(Refer to the user guide).
Ì
When the receiver LED has stopped
flashing. The products are associated.
OK
OFF
1 2 3 4
TYXIA
1 2 3 4
... ... ...
> 3s
1 2 3 4
TYXIA TYXIA
TYXIA 2600
TYDOM
A
B
COM
IN1
IN2
CR 20 32
TYXIA
2600
> 3s
A B
> 3s
IN1
COM
IN2
IN1
COM
IN2
IN1
COM
1
2
3
1
2
1
2
Do not interrupt the roller shutter travel.
Mode 1
Hold
switch
Mode 2
Double
push-button
Mode 3
Push button
3’
BA
> >6’’ 10’ 20’ 30’> >
C D E F
>
Association Remove an asso-
ciation
Remove
all associationsConfiguration Factory
reset
Quick press on the button.
A
Checking the transmitter operating mode.
Briefly press the button.
The LED flashes:
- 1 red flash: MODE 1 Hold switch
(Raise/Stop/Lower).
- 2 red flashes: MODE 2 Double push-button
(Raise/Lower).
- 3 red flashes: MODE 3 Single push-button
(Raise/Stop/Lower/Stop).
• Press and hold the button for x seconds.
B
Association (refer to §2)
- Press the receiver button for 3 seconds until
the LED flashes. Release
C
Configuration (refer to §3)
- Press the receiver's button for 6 seconds. The
LED flashes, then becomes steady, release.
D
Remove an association
(the removal method varies according
to the transmitter associated, refer to the
transmitter's user guide)
Example of removing a remote control
association.
On the receiver:
- Press the receiver button for 10 seconds until
the LED flashes rapidly, release.
On the remote control:
- Press the and buttons for 3 seconds.
- Make sure that the receiver LED has stopped
flashing. The products are no longer asso-
ciated.
E
Remove all associations
- Press the receiver's button for 20 seconds.
- Press and hold until the LED switches off after
the rapid flashing phase.
- Release. The receiver has no wireless connec-
tion.
F
Factory reset
- Press the receiver button for 30 seconds,
the LED flashes then switches off,
The receiver has no wireless connection and
the configuration is reset (mode 1 by default).
An additional user guide is available on the
TYXIA 5630 and TYXIA 5730 pages
of the DELTA DORE website.
www.deltadore.com
Support
The receiver locks in off mode
When an overload is detected, the product locks in off mode for 30
seconds before authorising a new activation.
The LED flashes rapidly throughout this phase.
For TYXIA 5630 receivers:
- Replace your receiver with a TYXIA 5730.
For TYXIA 5730 receivers:
- Contact our customer service.
20A circuit breaker
max. required.
Using the tool supplied
or a 2.5 mm screwdriver,
press the terminal button
then insert the wire.
TYXIA 5630 - TYXIA 5730
20 A
max.


Product specificaties

Merk: Delta Dore
Categorie: Receiver
Model: Tyxia 5730

Heb je hulp nodig?

Als je hulp nodig hebt met Delta Dore Tyxia 5730 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Delta Dore

Handleiding Receiver

Nieuwste handleidingen voor Receiver