Delta Dore Tyxia 5610 Handleiding

Delta Dore Receiver Tyxia 5610

Lees hieronder de 📖 handleiding in het Nederlandse voor Delta Dore Tyxia 5610 (1 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 106 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
Recommendations
• IMPORTANT: the control wires are not
insulated from the mains power supply.
All connected equipment must be
marked CE and meet the requirements of
the low voltage devices as well as assembly
recommendations.
Local control wires can be extended up
to 10 m (separate from the 230 V).
1 - Installation
1.1 Connection instructions for terminals 1 2 3 4.
- Strip the wires while respecting the strip
length specified on the product.
- Push the wire fully into the terminal.
1.1.1 Solid wires Stranded wires 1.1.2
1.2 Connection instructions for IN1 - COM - IN2 terminals
- Use the wires supplied.
- Push the wire fully into the terminal.
1.3 TYXIA 5610 connection - 1 output.
Connect:
- The light to terminals 3 and 4.
- The switch to the IN1 -
COM terminals (input 1).
- The 230 V power supply to
terminals 1 and 2.
Switch the installation power back
on to continue with the
association operation.
1.4 TYXIA 5612 connection - 2 outputs.
Connect:
- Light 1 to terminal 3 (Output 1) and light 2 to terminal 4 (Output 2).
- The control for light 1 to the IN1 and COM terminals (input 1).
- The control for light 2 to
the COM and IN2 terminals
(input 2).
- The 230 V power supply to
terminals 1 and 2.
Switch the installation power
back on to continue with the
association operation.
2 - TYXIA 5610 association
3 - TYXIA 5612 association
Ê
Select the channel to associate:
- Channel 1
- Channel 2
- Channel 1 and 2 simultaneously
- Press the button
for 3 seconds until
the LED flashes once, (channel 1 asso-
ciation mode),
release.
- Briefly press the button,
the LED flashes
twice, (channel
2 association mode), release.
- Briefly press the button,
the LED flashes 3 times, (association
mode for channel 1 and channel 2
simultaneously), release.
Ë
After selecting the channel to associate.
On the transmitter:
- Send the association command
(Refer to the user guide).
When the receiver LED has stopped flashing.
The products are now associated.
4 - Troubleshooting
Summary of functions accessible using the receiver button:
• Press and hold the button for x seconds.
AAssociation/Configuration
- Press the receiver button for 3 seconds until the LED flashes. Release
BRemove an association
(the removal method varies according to the transmitter associated, refer to
the transmitter's user guide)
Example of removing a remote control association.
On the receiver:
- Press the receiver button for 10 seconds until the LED flashes rapidly, release.
On the remote control:
- Press the and buttons for 3 seconds.
- Make sure that the receiver LED has stopped flashing. The products are no longer
associated.
IMPORTANT: For the TYXIA 5612, this action removes the association on both
channels.
CRemove all associations
- Press the receiver's button for 20 seconds.
- Press and hold until the LED switches off after the rapid flashing phase.
- Release. The receiver has no wireless connection.
The receiver locks in off mode
When an overload is detected, the product locks in off mode for 30 seconds before
authorising a new activation. The LED flashes rapidly throughout this phase.
To exit the receiver from this secure mode, replace the bulb connected by a bulb
with lower power (refer to compatibility table).
The command (push button or switch) does not work correctly:
Switch off the mains and wait for 5 second before turning the power back on again,
then perform the following steps depending on the command type:
Push button: Press and release the push button 3 times:
Switch: Operate the switch 3 times (wait for 3 seconds between each switching
action)
0,75 - 1,5 mm
Ø
2
2
1
2
7mm 0,5 mm
KY31A02
123 4
230V
230 V~
1
IN1
COM
TYXIA
5610
1234
230V~
200W max
1234
Standby 0.06W
230 V~ 0.6 VA
IN1
COM
IN1
COM
ON
OFF
ON
OFF
230V~
µ
N S1NL
TYXIA 2600
TYDOM
A
B
COM
IN1
IN2
CR 2032
TYXIA
2600
> 3s
A B
> 3s
TYXIA
5612
OK
OFF
1 2 3 4
S1 S2
µ
EN
Technical characteristics
- Power supply: TYXIA 5610: 230 V~ 0.6 VA
TYXIA 5612: 230 V~ 0.9 VA
- Stand-by consumption: 0.06 W
- Number of associated emitters: 16 max. per channel
- Storage temperature: -10°C/+70°C
- Operating temperature: -10°C/+40°C
- IP 40 (flush mounting box)
- Dimensions: 41 x 36 x 14.5 mm
- X3D wireless remote control device:
868.7 MHz to 869.2 MHz
- Maximum radio power < 10 mW
- Receiver category: 2
EN Lighting
receiver
An additional user guide is available on the TYXIA 5610 and TYXIA
5612 pages of the DELTA DORE website. www.deltadore.com
Compatibility
À 230 V halogen or 230 V incandescent bulbs.
Á 230V energy-saving compact uorescent bulbs.
Â230V LED bulbs.
à Very low voltage 12V halogen or LED bulbs with AC or DC
electronic transformer.
Ä Very low voltage 12V halogen bulbs with ferromagnetic or
toroidal transformer.
Å Fluorescent tube.
Do not connect different types of loads to the same output.
Use an electrically
isolated tool to per-
form the actions on the
receiver configuration
button.
TYXIA
Switch off the installation
power supply
230V~
OFF
- You can install the lighting receiver in a
flush-mounted box behind a switch or control
push-button (automatic detection on use)
or behind a ceiling.
Using the tool
supplied or a 2.5 mm
screwdriver, press
the terminal button
then insert the wire.
Removal recommendations
- Switch off the power supply.
- Use the tool supplied or a 2.5 mm screwdri-
ver to press the button of the front terminal
before removing the wire. 2
1
Do not strip the wires when they are
connected to the product as you
could damage the internal connector.
1
2
123 4
Removal recommendations
Turn the wire while pulling on it.
230 V~
1
2
1 2
IN1
IN2
COM
TYXIA
5612
1234
230V~
200W max
1 2 3 4
Standby 0.06W
230 V~ 0.9 VA
S1 S2
µ
ON/OFF
ON/OFF
ON/OFF
ON/OFF
IN1
COM
IN2
IN1
COM
IN2
1
2
1
2
TYXIA 2600
TYDOM
A
B
COM
IN1
IN2
CR 2032
TYXIA
2600
> 3s
A B
> 3s
1 2 3 4
TYXIA
5610
TYXIA
5610
... ... ...
> 3s
µ
N S1NL
µ
N S1NL
Ê
Press and hold the receiver but-
ton for 3 seconds until the LED
flashes, release.
Ë
On the transmitter:
- Send the association command
(Refer to the user guide).
Ì
When the receiver LED has stopped
flashing. The products are now asso-
ciated. 1 2 3 4
TYXIA
5610
OK
OFF
µ
N S1NL
TYXIA
5612
... ... ...
...
...
...
> 3s
S1
S2
TYXIA
5612
TYXIA
5612
...
S1
S2
TYXIA
5612
+
1 2 3 4
S1 S2
µ
1 2 3 4
S1 S2
µ
1 2 3 4
S1 S2
µ
1 2 3 4
S1 S2
µ
3’
A
>10’’ 20’>
C
>
B
Association/
Configuration
Remove an
association
Remove
all associations
200 W 100 W 100 W100 W100 W
LEDLED
150 W 100 W
M
Hi-Fi
230 V~ 50 Hz
20A circuit breaker
max. required.
TYXIA 5610 - TYXIA 5612
www.deltadore.com


Product specificaties

Merk: Delta Dore
Categorie: Receiver
Model: Tyxia 5610

Heb je hulp nodig?

Als je hulp nodig hebt met Delta Dore Tyxia 5610 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Delta Dore

Handleiding Receiver

Nieuwste handleidingen voor Receiver