QUICK REFERENCE GUIDE
Ovation P-56UV QRG Rev. 6
About This Guide
The Ovation P-56UV Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu
options, and DMX values. Download the User Manual from www.chauvetprofessional.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration/
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in and subject to the exclusions and limitations set forth in, the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
• DO NOT open this product. It contains no user-serviceable parts.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
• ULTRAVIOLET LIGHT! DO NOT look at the light source when the product is on. Wear proper eye and skin
protection.
• Do not view the beam directly with optical instruments such as magnifiers, telescopes, binoculars or similar optical
instruments that may concentrate the light output.
• Ensure no one is accidentally exposed to the light beam from short distances.
• CAUTION: This product’s housing may be hot when lights are operating.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
• DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
• CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
• USE a safety cable when mounting this product overhead.
• DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it. (IP20)
• DO NOT operate this product if the housing, lenses, or cables appear damaged.
• DO NOT connect this product to a dimmer or rheostat.
• ONLY connect this product to a grounded and protected circuit.
• ONLY use the hanging/mounting bracket to carry this product.
• In the event of a serious operating problem, stop using immediately.
• The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Visit Contact Us at the end of this QRG for contact information.
What is Included
• Ovation P-56UV
• Gel frame holder (7.5 in/191 mm accessories)
• Neutrik® powerCON® power cord
• Wide lenses
• Quick Reference Guide
EN
2
Ovation P-56UV QRG Rev. 6
QUICK REFERENCE GUIDE
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
You can link up to 13 Ovation P-56UV products at 120 V, 21 products at 208 V, or 23 products at 230 V. Never exceed this
number. Power-linking cords can be purchased separately.
AC Plug
Replacing The Fuse
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power
DMX Linking
The Ovation P-56UV will work with a DMX controller using a 3- or 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Ovation P-56UV uses a 3- or 5-pin DMX data connection for its DMX personalities: 1 Ch, 2 Ch, , 3 Ch and 6 Ch. See
the User Manual for information about connecting and configuring the product for DMX operation.
Master/Slave Connection
The Ovation P-56UV uses the DMX data connection for its master/slave mode. See the User Manual for information
about how to connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers
have this capability. The Ovation P-56UV supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from www.chauvetprofessional.com for more details.
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps/
Product Mounting Diagram
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
!
Safety cable
Mounting clamp
Overhead Mounting Floor Mounting


Product specificaties

Merk: Chauvet
Categorie: Niet gecategoriseerd
Model: Ovation P-56UV

Heb je hulp nodig?

Als je hulp nodig hebt met Chauvet Ovation P-56UV stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Chauvet

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024