BE1289 SMOKE ALARM
AS 3786
: 2014
Overview
Read this ๎€Ÿrst. Thank you for purchasing this Visit smoke alarm which is an important part of the Visit
alerting system from Bellman & Symfon. Read and keep this user manual for as long as the product is
being used. It contains vital information on the operation and installation of your smoke alarm. The user
manual should be regarded as part of the product. If you are just installing the unit, the user manual must
be given to the householder. The user manual is to be given to any subsequent user.
Getting started 4
Using interconnection 6
Location and positioning 8
Fire safety advice 11
Alarm limitations 13
Radio module features 14
Test and maintenance 15
Troubleshooting 17
Technical speci๎€Ÿcations 18
Warranty conditions 19
Contents
Note: This smoke alarm is equipped with a radio module that transmits radio
signals to one or more supplementary Visit receivers. The Visit receivers help
hard of hearing and deaf people to notice the alarm. The characteristics of
the alarms are explained in the Visit receiverโ€™s user manual.
Signal horn
Status LED Test/Silence button Built-in batteries
Radio LED Mounting plate
32
On/O๎€ž switch
Signal pattern
The smoke alarm status LED blinks in red every 40 s to show that it is working correctly.
Depending on the cause of the alarm, the signal patterns are as follows:
Silence function
In case of a nuisance alarm, press the test button to silence it temporarily. The status LED
blinks every 8 s to con๎€Ÿrm. For security reasons, the silence function stops after 10 minutes.
Note: Only use this feature if you are certain about the cause of the alarm, like for instance
harmless cooking fumes. If you have interconnected smoke alarms, you need to silence the unit
that blinks to stop the other units from sounding. If more than one unit is blinking, you need to
silence each smoke alarm separately.
Test interval
It is recommended that you test your smoke alarms and Visit receivers at least weekly to
ensure the units are working, see 'Test and maintenance'.
Power monitoring
When the battery starts to run out, the smoke alarm chirps and blinks every 40 s for a
minimum of thirty days. This smoke alarm features a sealed non-replaceable battery, so
when the battery is depleted you need to replace the unit, see 'End of life'.
Smoke alarm Visit receiver
Cause Status LED Sound LED Sound Vibration Flash
Fire/Test Blinks every s 3 beeps every 4 s Red Fire alarm Long Yes
Low battery Blinks every 40 s Chirps every 40 s โ€” โ€” โ€” โ€”
Faulty unit โ€” Chirps every 40 s โ€” โ€” โ€” โ€”
Getting started
Installation
1 Remove the mounting bracket from the smoke alarm by turning it counter-clockwise.
2 Taking care to avoid any electrical wiring, ๎€Ÿx the mounting bracket to the ceiling or wall
using the supplied screws and plugs. For placement, see 'Location and positioning'.
3 Fit the smoke alarm to the bracket by turning it clockwise until is snaps into place. The
status LED blinks in red every 40 s to show that the unit is on.
1 2 3
Testing
1 Press the test button on the smoke alarm
and release it when the unit starts to beep.
2 The red Visit LED blinks on the receiver and
it starts to sound, ๎€ash or vibrate depending
on your receiver. It will time out in about 40 s.
If you have interconnected smoke alarms
(see page 6), they will beep for 10 s and
blink for 5 min. To mute them, press the
test button on each unit.