Aritech FP-FR 2000 Series Handleiding

Aritech Beveiliging FP-FR 2000 Series

Lees hieronder de 📖 handleiding in het Nederlandse voor Aritech FP-FR 2000 Series (60 pagina's) in de categorie Beveiliging. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/60
FP/FR1100/1200/
2000 Series
Analogue addressable fire panels,
repeaters and emulators
Installation and
Commissioning Manual
Revision 6.2: February 2003
ARCNET is a registered trademark of Datapoint Corporation.
Aritech is an Interlogix company.
www.aritech.com
COPYRIGHT
© 2001 Interlogix B.V.. All rights reserved. Interlogix B.V. grants the right to reprint this manual for internal use only. Interlogix B.V.
reserves the right to change information without notice.
FP/FR1100/1200/2000 V6: Installation and Commissioning Manual 1
CONTENTS
1 INTRODUCTION............................................................................................................................................ 4
2 GENERAL INFORMATION............................................................................................................................... 5
2.1 Product codes ..................................................................................................................................... 5
2.2 Design specifications........................................................................................................................... 7
3 TECHNICAL SPECIFICATIONS ........................................................................................................................ 9
3.1 General specifications......................................................................................................................... 9
3.2 Panel specifications........................................................................................................................... 11
3.2.1 Standard Outputs ................................................................................................................. 11
3.2.2 Standard Inputs .................................................................................................................... 12
3.2.3 Power Supply Characteristics............................................................................................... 12
3.2.4 Panel Operation.................................................................................................................... 14
3.2.5 Environmental....................................................................................................................... 15
4 MOUNTING INSTRUCTIONS ......................................................................................................................... 15
4.1 FP/FR12xx ........................................................................................................................................ 15
4.1.1 Panel dimensions ................................................................................................................. 15
4.1.2 Mounting instructions............................................................................................................ 16
4.1.3 Panel & repeater layout ........................................................................................................ 17
4.2 FP2xxx .............................................................................................................................................. 18
4.2.1 Panel dimensions ................................................................................................................. 18
4.2.2 Mounting instructions............................................................................................................ 19
4.2.3 Panel layout.......................................................................................................................... 21
4.2.4 Repeater layout .................................................................................................................... 22
5 LOOP DESIGN (FP12XX/FP2XXX/FB2X00 ONLY) ........................................................................................ 23
5.1 Typical configuration ......................................................................................................................... 23
5.2 Suitable cable types .......................................................................................................................... 25
6 FIELD CONNECTIONS ................................................................................................................................. 26
6.1 Loop, output and input connections .................................................................................................. 26
6.1.1 FP12xx ................................................................................................................................. 26
6.1.2 FP2xxx.................................................................................................................................. 27
6.2 Connections ...................................................................................................................................... 28
6.2.1 Loop connections ................................................................................................................. 28
6.2.2 Programmable relay............................................................................................................. 30
6.2.3 Supervised outputs A ........................................................................................................... 31
6.2.4 Relay outputs B .................................................................................................................... 31
6.2.5 Supervised inputs IN5 - IN8.................................................................................................. 33
6.2.6 Auxiliary inputs (FEP2000 only)............................................................................................ 34
6.2.7 Connection of dual tone siren AS263/AS264 ....................................................................... 35
6.3 Communication port connections (all models) .................................................................................. 36
6.3.1 Current loop.......................................................................................................................... 36
6.3.2 RS232 ports.......................................................................................................................... 37
6.4 Power supply connections................................................................................................................. 38
6.4.1 24 V version FR2xxx models................................................................................................ 38
6.4.2 230 V version (FP/FR1xxx/FR2000 models – except FP1216EN & FP1264) ..................... 39
6.4.3 FP1216EN & FP1264 Power supply connections ................................................................ 42
6.4.4 230 V version (FP2xxx models) ........................................................................................... 43
6.5 Installing a modem ............................................................................................................................ 45
6.6 Network connections......................................................................................................................... 47
6.6.1 NC2011/NC2051 ARCNET network cards........................................................................... 47
6.6.2 NE2011/NE2051 ARCNET network extension cards........................................................... 48
6.6.3 FP/FBP/FRL700 Serial communication network (LON2000) ............................................... 49
6.7 LCD contrast ..................................................................................................................................... 50
6.7.1 FP/FR2xxx............................................................................................................................ 50


Product specificaties

Merk: Aritech
Categorie: Beveiliging
Model: FP-FR 2000 Series

Heb je hulp nodig?

Als je hulp nodig hebt met Aritech FP-FR 2000 Series stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Beveiliging Aritech

Handleiding Beveiliging

Nieuwste handleidingen voor Beveiliging