Zone 4 professional preamp has 4 stereo line source inputs on RCA connectors plus 3 mono mic/line balanced inputs
on euroblocks. All mic inputs feature individual sensitivity, level and tone control. Mic 2 and 3 inputs have switchable
phantom power. Each mic signal can be assigned to any of the 4 available zone outputs.
Microphone input 1 controls and connectors are available at the rear of the unit, featuring a balanced mic input with
priority switch and zone assign preset dipswitches. If you need more exibility and ease of installation, simply connect
our APart selective paging station MICPAT-4 instead, it will override the mic 1 zone assignments.
Mic 2 and 3 inputs can be controlled and assigned via the front panel controls. In order to avoid any abuse by the end
user, you can hide the microphone controls with the supplied cover plate.
Zone 1 to 4 stereo outputs can be individually conî‚¿gured as mono or stereo outputs and are available on RCA con-
nectors. Every zone has its own line input selector, bass and treble tone control and music level control. Every zone
also has its own microphone mix level control. Music and mic mix can be muted/unmuted manually per zone by simply
pushing the level knob.
System integrators will be pleased to î‚¿nd a RS232 port at the back, allowing full control of the most important system
parameters.
If you need to control the zones locally, you can always add a wired remote, APart model ZONE4R to any zone. Wiring
is simple, using standard RJ45 connectors and CAT5 cable.
Finally there is the IR input port. This port can be used to connect our optional PIR-REC infrared receiver. There is no
infrared remote control available for the ZONE4 unit. We have added the infrared codes for those who want to program
their universal infrared control unit.
1. Disconnect paging led : this led is lit when you push the disconnect paging button ‘2’.
2. Disconnect paging button : push this button to disable the paging function. This can be convenient in case you
want to avoid accidental paging and thus muting of the line inputs. Note that mic 2 and mic 3 are still active.
The paging button(s) will not mute the music (or line signals). Mic 1 will be entirely disabled.
3. Zone assign dipswitches mic 2 : with these dipswitches you can assign the mic 2 signal to zone 1 to 4.
4. Zone assign dipswitches mic 3 : with these dipswitches you can assign the mic 3 signal to zone 1 to 4.
5. Mic 2 tone control : turn the knob to darken the tone (turn to the left) or to brighten the tone (turn to the right).
6. Mic 3 tone control : turn the knob to darken the tone (turn to the left) or to brighten the tone (turn to the right).
7. Mic 2 level control : turn the knob to the right to increase mic 2 level or to the left to reduce the level.
8. Mic 3 level control : turn the knob to the right to increase mic 3 level or to the left to reduce the level.
9. Mic signal/clip led : this led is green when a signal is present on mic 2 input and is red when the input is over-
loaded. Reduce the gain knob at the rear to avoid overload and distortion.
10. Mic signal/clip led : this led is green when a signal is present on mic 3 input and is red when the input is over-
loaded. Reduce the gain knob at the rear to avoid overload and distortion.
11. Zone 1 line input selector switches : use these switches to scroll through line input A to D. The selected input is
shown in the display ‘12’ as A, b, C, d.
12. Multifunctional 7 segment LED display : this display shows the currently selected line input. When you change
the mic or music level by turning the knobs 15 or 17, the actual level is shown in the display for a few seconds.
13. Lo tone control : push the + or – buttons to increase or decrease the bass tones in zone 1. This tone control
has no inuence on the mic tone control and will adjust the tone on line signals only.
14. Hi tone control : push the + or – buttons to increase or decrease the high tones in zone 1. This tone control
has no inuence on the mic tone control and will adjust the tone on line signals only.
15. Zone 1 music level control : turn this knob to adjust the zone 1 music level. If you push this button, the music
will be muted. Pushing a second time will unmute the music signal in zone 1. This is indicated by led ‘16’.
16. Music mute led : this led lights up when the music in zone 1 is muted by pushing the ‘15’ knob or by activating
paging.
17. Mic mix level control zone 1 : turn this knob to adjust the zone 1 mic mix level. If you push this button, the mic
mix signal will be muted. Pushing a second time will unmute the mic mix signal in zone 1. This is indicated by
led ‘18’.
18. Mic mix mute led : this led lights up when the mic mix in zone 1 is muted by pushing the ‘17’ knob. Please note
that this will not disable the paging function of the mics, in other words : if the microphone signal is muted, but
when paging is activated, the music level will be muted also, unless you activate disconnect paging (button
‘2’).
19. On/off switch : ip this switch to turn the unit on or off.
20. Power led : this led is lit when the power is on. When the unit is set to stand-by via RS232, then this led will
still be lit to indicate that mains power is still present.
1 2
3
4 6 8 10 13 14 16 18
5 7 12 15 179 11
19