Andrews Zephyr ET Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Andrews Zephyr ET (4 pagina's) in de categorie Airconditioner. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs of
damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a
standard BS1363 domestic socket.
Always inspect plugs and leads for damage before plugging into
the supply - DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard ,
and fully uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
WARNING!
As standard this unit requires a 13 amp fused electrical supply rated at
230v 1ph 50hz.
The unit will operate from a standard 13A wall socket. The size of any
extension cable that may be 2-5mm2 minimum up to a maximum
length of 10 metres. For longer lengths 4mm2 cable must be used.
If the cable is on a ‘cable drum’ then ensure that it is completely
unwound; serious complications will occur otherwise.
Air Cooled Units
The system comprises, a room unit fitted with either a fixed or flexible
ducting system as specified by the customer. Condensate is collected,
either in the units internal tank and emptied by the user or pumped
using an optional condensate disposal unit (fig. 1).
Air Flow
The angled air outlets at the top of the room unit are fitted with air grilles
that allow the angle of air outlet to be adjusted vertically and horizontally
and, in conjunction with the fan speed control switch, the air velocity
and direction can be carefully set up to obtain maximum coverage of
the area being cooled without causing drafts. Care should be taken
to avoid outlet air being obstructed as this will cause the air to ‘eddy’
around the unit resulting in recirculation and short/inaccurate cycling of
the machine. Ideally, cold air should be directed to create a ‘blanket’ all
across the ceiling area allowing natural convection to drop the air over
the whole area at very low velocity. An alternative top panel with twin 7”
ducts is available.
Siting of Zephyr
Ideally, the room unit should be positioned equidistant along he shortest
wall in the room blowing down the length of the room. Of there is more
than one unit in the same area, then they would normally be positioned
side by side, and equidistant along the long wall, all pointing in the
same direction. Sometimes it may be necessary to position units
around the perimeter of an area but, in this case, great care should
be taken t avoid one unit blowing cold air straight into another which
will adversely affect the machine operation. Good and correct air flow
is, perhaps, the single most important aspect of satisfactory applying
portable air conditioners. If in doubt seek the advice of your supplier.
Exhaust Tubes Air Cooled Unit
The exhaust tube(s) must carry the air to an area external to that being
cooled, preferably in the outside atmosphere (fig. 1).
Click www.andrews-sykes.com
or Call Us Free 0800 211 611
Zephyr ET
Portable Air Conditioning
Operating Instructions
& Safety Guide
Operation Instructions
The control panel on the room unit is illustrated below
Revolve thermostat knob fully CLOCKWISE to the number ‘8’ position
Plug in the room unit mains cable, and switch on the electricity, red
mains light will illuminate.
Select ‘Fan Only’ with the mode switch. The fan will start.
Select ‘Fan Speed’ with the fan speed switch, high or low
depending on air velocity required.
Select ‘Cooling’ with the mode switch, and revolve the thermostat
knob fully ANTI-CLOCKWISE to he number ‘1’ position. After a
delay of 10 mins the green ‘Coolinglight will illuminate and the
machine will proceed to cool the air.
Monitor the room temperature and when it has reduced to the desired
level, very slowly revolve the thermostat knob back, clockwise until the
greenCooling’ light goes out. The room unit will now control the room
temperature cooling automatically at this setting.
Routine Maintenance
The air filter must be kept clean, never allow to become choked with
dust or dirt. If allowed to do so, the performance of the unit will become
impaired, resulting in loss of air flow, freezing up the evaporator coil and
possible component damage.
Accessing the Filter
On machines fitted with a hinged lower panel, open panel. The filter is
located on front of the evaporator. A second filter is fitted to the rear panel
on all air cooled machines.
On machines without a hinged front panel, to access the filter, lift out the
return air grille on the front face of the unit. On refitting the filter ensure that
it is correctly positioned covering the whole face of the grille.
The filter (see Fig 4) can be washed in warm, soapy water, rinsed and
shaken dry before replacement. Frequency of cleaning depends upon
Operating Instructions - Zephyr ET
Click www.andrews-sykes.com 0800 211 611or Call Us Free
application and can only be determined by the user. However, you should
never allow more than two months to elapse between cleaning. The
probable life of the filter will be about one year and spares are available
from the supplier of the unit itself. Failure to have lter tted during
operation will cause serious damage (see fig. 4 / 5).
Problem Likely Cause Solution
No cooling Amber ‘ATTENTION’
light illuminated. High
level condensate trip.
Condensate pump not reducing water level.
Kink in condensate tube between room
unit and external heat exchanger? Leak
inside room unit. Pump filter inside room unit
blocked. Condensate tube frozen.
No cooling Amber ‘ATTENTION’
light illuminated. Bottle
fitted switch trip.
On machines without a removable
bottle, ensure link fitted to terminal
block. On machines with , ensure bottle
fitted correctly.
No cooling Amber ‘CONTAINER
FULL’ light illuminated.
High level condensate
trip.
On machines without a removable
bottle, as above. On machines with a
bottle, remove container and replace
correctly. To empty the condensate
bottle, pull forward the lower front panel,
(Fig 2).
The front cover will come forward, giving
access to the container, (Fig 3).
Empty the container, and carefully
replace.
Ensure the drain pipe is fitted into the
container.
The filter is located on the rear of the
unit, ensure it is kept clean.
Fitting the hot air exhaust
Fig.2
Fig.3 Fig.4
Fig.5
Fig.1


Product specificaties

Merk: Andrews
Categorie: Airconditioner
Model: Zephyr ET

Heb je hulp nodig?

Als je hulp nodig hebt met Andrews Zephyr ET stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airconditioner Andrews

Handleiding Airconditioner

Nieuwste handleidingen voor Airconditioner