Andrews PAC15 Handleiding
Andrews
Airconditioner
PAC15
Lees hieronder de 📖 handleiding in het Nederlandse voor Andrews PAC15 (3 pagina's) in de categorie Airconditioner. Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/3
Click www.andrews-sykes.com
or Call Us Free 0800 211 611
PAC15
Portable Air Conditioning
Operating Instructions
& Safety Guide
General Safety
Keep children and animals away from air conditioning units. Never
leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use.
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs
of damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a standard BS1363
domestic socket.
Always inspect plugs and leads for damage before plugging into the supply -
DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard , and fully
uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
Machine not working?
ONLY A COMPETENT ELECTRICIAN SHOULD ATTEMPT TO RECTIFY
ELECTRICAL SUPPLY PROBLEMS. DO NOT REMOVE ANY PANELS FROM
THE MACHINE.
Problem Likely Cause Solution
No air flow from the
room unit
Red ‘MAINS’ light off Turn on electricity and/or check mains
supply fuse
No air flow from the
room unit
Red ‘MAINS’ light on.
White ‘DEFROST’
light on
Machine is in defrost mode, do not
adjust anything, machine will revert to
normal run after 10 mins
Insufficient air flow
from the room unit
Blocked air filter Clean filter
No cooling Green ‘COOLING’
light off
Revolve thermostat knob fully anti-
clockwise to ‘1’. Wait 10 minutes for
time delay on start-up.
No cooling Amber ‘ATTENTION’
light illuminated. High
pressure trip.
Press ‘+’ button to re-set and check for:
Lack of water flow...kinked hoses?
Shortage of water..... top up.
External heat exchanger unit mounted in
very high temperature?
Water frozen? Add glycol (33%)
External heat exchanger coil blocked
with dirt.... clean
Air cooled units.... lack of air flow from
exhaust.... kinked or blocked duct, duct
too long.
No cooling Amber ‘ATTENTION’
light illuminated. Low
pressure trip.
Press ‘-’ button to re-set and check for:
No air flow, blocked filter?
Evaporator blocked with ice. Very low air
temperature?
No cooling Amber ‘ATTENTION’
light illuminated. High
level condensate trip.
Condensate pump not reducing water
level. Kink in condensate tube between
room unit and external heat exchanger?
Leak inside room unit. Pump filter inside
room unit blocked. Condensate tube frozen
Routine Maintenance
The air filter must be kept clean, never allow to become choked with dust or dirt.
If allowed to do so, the performance of the unit will become impaired, resulting in
loss of air flow, freezing up the evaporator coil and possible component damage.
To access the filter, lift out the return air grille on the front face of the unit (fig. 4). On
refitting the filter ensure that it is correctly positioned covering the whole face of the grille.
The filter (see fig. 4) can be washed in warm, soapy water, rinsed and shaken dry
before replacement. Frequency of cleaning depends upon application and can
Fig. 4
Operating Instructions - PAC15
Click www.andrews-sykes.com 0800 211 611or Call Us Free
only be determined by the user. However, you should never allow more than two
months to elapse between cleaning. The probable life of the filter will be about one
year and spares are available from the supplier of the unit itself. Failure to have filter
fitted during operation will cause serious damage.
The refrigeration circuit inside the room unit is fitted with a HIGH and a LOW
pressure sensing switch. They are both manually re-settable. Necessary access is
provided either via the lower front panel or through the control console. A pencil or
screwdriver with gentle pressure on the knob behind is all that is required to re-set.
HOWEVER, DO NOT ATTEMPT TO RE-SET WITHOUT FIRST DISCOVERING
WHY THE TRIP OCCURRED IN THE FIRST PLACE
Installation
USE THE CHAINS PROVIDED TO SUPPORT THE HEAT EXCHANGER - IT
WOULD BE HIGHLY DANGEROUS TO SUPPORT THE HEAT EXCHANGER BY
MEANS OF THE FLEXIBLE LINES ALONE.
In operation the room unit is constantly condensing water vapour out of the
atmosphere (reducing relative humidity). This water has to be drained away, An
automatic condensate pump is fitted inside the room unit. The flexible hose outlet
from the condensate pump runs to the outside, inside the flexible sheath and the
condensate is deposited in the base of the heat exchanger, but please remember
that there will also be a degree of dripping through the base of the heat exchanger.
HAVE GREAT REGARD FOR THIS CHARACTERISTIC WHEN POSITIONING THE
EXTERNAL HEAT EXCHANGER
The flexible water pipes should be routed so as to avoid any possibility of kinking
or unnecessary restrictions to the flow of water inside. Also, remember that plastic
and rubber becomes much more flexible when warm and. as a result, much more
susceptible to distortion.
Machine Link-Up
Ensure the mains supply lead to the room unit is disconnected, A 5m (extendable
to 30m) line set to connect all services between the room unit and the external
heat exchanger will have been suppled. The water pipe connections are by means
of ‘quick connect couplers’ . These are simple ‘push-on’ connectors which,
when disconnected (after pulling back sprung loaded locking ring), re-seal the
water system on either side. The complete system will have been filled with the
necessary amount of water/ antifreeze prior to its arrival on site. A water proof 3
pin quick connect electrical coupler (push fit with screw lock ring, hand tight only),
and condensate drain pipe coupler 6mm clear polythene (push fit), should also be
connected. Having made the couplings, the system is operational immediately.
Room Water Levels
The water system in the room unit will be to the correct level when delivered.
However if for some reason the level has fallen, antifreeze (33%) and water will have
to be added. The header tank filler and level indication is located to the rear of the
room unit and can be accessed by removing the two screws holding the security
plate over the filter tank cap. Ensure the machine is running in cooling mode
before removing the header tank cap, and as with all the pressure caps, remove
slowly. It is recommended that a mixture, by volume, of one part antifreeze to two
parts water is utilised, this will prevent freezing down to an external temperature
of -20C/-5F. The approximate total volume of both the available systems, large or
small room unit with external heat exchanger and lines is as follows.
This unit MUST be transported and operated in the upright position at all times.
Electrical Supply
WARNING! As standard this unit requires a 13 amp fused electrical supply rated at
230 volts. -1N, 50Hz.
The unit will operate from a standard 13A wall socket. The size of any extension
cable that may be 2-5mm2 minimum up to a maximum length of 10 metres. For
longer lengths 4mm² cable must be used. If the cable is on a ‘cable drum’ then
ensure that it is completely unwound; serious complications will occur otherwise.
System Description
The system comprises a room unit cooling section, an external heat exchanger
and the two are interconnected by means of a flow and return water pipe and
an electrical supply to the heat exchanger fan. The room unit is fitted with an
automatic condensate disposal pump which discharges the condensate via a small
plastic pipe into the base of the external heat exchanger and all interconnecting
pipes and electrics are enclosed in a flexible plastic sheath. In addition, both ends
of each pipe are fitted with ‘quick connect’ couplings that open on coupling but
reseal to become water tight on disconnect.
Airflow
The angled air outlets at the top of the room unit are fitted with air grilles that allow
the angle of air outlet to be adjusted vertically and horizontally and, in conjunction
with the fan speed control switch, the air velocity and direction can be carefully set
up to obtain maximum coverage of the area being cooled without causing drafts.
Care should be taken to avoid outlet air being obstructed as this will cause the air
to ‘eddy’ around the unit resulting in recirculation and short/inaccurate cycling of
the machine. Ideally, cold air should be directed to create a ‘blanket’ all across the
ceiling area allowing natural convection to drop the air over the whole area at very
low velocity.
Siting
Ideally, the room unit should be positioned equidistant along he shortest wall in the
room blowing down the length of the room. Of there is more than one unit in the
same area, then they would normally be positioned side by side, and equidistant
along the long wall, all pointing in the same direction. Sometimes it may be
filler cap
necessary to position units around the perimeter of an area but, in this case, great
care should be taken to avoid one unit blowing cold air straight into another which
will adversely affect the machine operation. Good and correct air flow is, perhaps,
the single most important aspect of satisfactory applying portable air conditioners.
If in doubt seek the advice of your supplier.
The heat exchanger must stand external to the area being cooled and, preferably,
in the outside atmosphere. It can stand freely on a flat surface or may be hung in
the upright position, from a window-sill, balcony etc (see fig. 1).
1. Revolve thermostat knob fully
CLOCKWISE to the number ‘8’ position
2. Plug in the room unit mains cable, and
switch on the electricity, red mains light
will illuminate.
3. Select ‘Fan Only’ with the mode switch.
The fan will start.
4. Select ‘Fan Speed’ with the fan speed
switch, high or low depending on air
velocity required.
5. Select ‘Cooling’ with the mode switch,
and revolve the thermostat knob fully
ANTI-CLOCKWISE to he number ‘1’
position. If fitted the external heat
exchanger fan and the water pump in
the room unit will start. After a delay of
10 mins the green ‘Cooling’ light will
illuminate and the machine will proceed
to cool the air.
Monitor the room temperature and when it has reduced to the desired level, very slowly
revolve the thermostat knob back, clockwise until the green ‘Cooling’ light goes out. The
room unit will now control the room temperature cooling automatically at this setting.
Fig. 1
Fig. 2
Product specificaties
Merk: | Andrews |
Categorie: | Airconditioner |
Model: | PAC15 |
Heb je hulp nodig?
Als je hulp nodig hebt met Andrews PAC15 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airconditioner Andrews
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
Handleiding Airconditioner
- Airconditioner Electrolux
- Airconditioner Bosch
- Airconditioner Samsung
- Airconditioner Panasonic
- Airconditioner LG
- Airconditioner AEG
- Airconditioner Bauknecht
- Airconditioner BEKO
- Airconditioner Daewoo
- Airconditioner Honeywell
- Airconditioner Inventum
- Airconditioner Toshiba
- Airconditioner Vaillant
- Airconditioner Whirlpool
- Airconditioner Zanker
- Airconditioner Zibro
- Airconditioner Acson
- Airconditioner Aermec
- Airconditioner Aertesi
- Airconditioner Aircool
- Airconditioner Aircooler
- Airconditioner Airlux
- Airconditioner Airview
- Airconditioner Airwell
- Airconditioner Akai
- Airconditioner Akira
- Airconditioner Alaska
- Airconditioner Alberello
- Airconditioner Amcor
- Airconditioner Argo
- Airconditioner Ariston
- Airconditioner Bryant
- Airconditioner D-Let
- Airconditioner Daikin
- Airconditioner Dimplex
- Airconditioner Domair
- Airconditioner Dometic
- Airconditioner Duux
- Airconditioner Edgestar
- Airconditioner Einhell
- Airconditioner Emerio
- Airconditioner Emmeti
- Airconditioner Eurom
- Airconditioner Fakir
- Airconditioner Frigor
- Airconditioner Fujitsu
- Airconditioner Galanz
- Airconditioner Gutfels
- Airconditioner H.Koenig
- Airconditioner Haier
- Airconditioner Handson
- Airconditioner Heiko
- Airconditioner Innova
- Airconditioner Kenmore
- Airconditioner Klarbach
- Airconditioner Klima1stKlaas
- Airconditioner Koenig
- Airconditioner Maiko
- Airconditioner MDV
- Airconditioner Mizushi
- Airconditioner Mobile Airco
- Airconditioner MPM
- Airconditioner MundoClima
- Airconditioner Qlima
- Airconditioner Qlima - Zibro
- Airconditioner Rowenta
- Airconditioner Shinco
- Airconditioner Sinclair
- Airconditioner SMD
- Airconditioner TechnoLife
- Airconditioner Telair
- Airconditioner Termozeta
- Airconditioner Thermo Comfort
- Airconditioner Tosot
- Airconditioner Trotec
- Airconditioner Ufesa
- Airconditioner Olimpia Splendid
- Airconditioner OneConcept
- Airconditioner Inventor
- Airconditioner Day
- Airconditioner Zymbo
Nieuwste handleidingen voor Airconditioner
18 Maart 2023
5 Februari 2023
5 Februari 2023
5 Februari 2023
2 Januari 2023
5 Februari 2023
4 Januari 2023
2 Januari 2023
8 Maart 2023