Pagina 1/6
Click www.andrews-sykes.com
or Call Us Free 0800 211 611
PAC 14
Portable Air Conditioning
Operating Instructions
& Safety Guide
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
Maintenance
Disconnect from the electrical supply before any cleaning or
maintenance.
Clean eternal surfaces with a clean, damp cloth. Do not use solvents.
Check the air filter everywhere every week.
1. Pull forward the front panel (fig 3).
2. The filter may not be removed (fig 4).
The filter may be cleaned in warm soapy water (40°C). RInse and dry
completely before replacing.
Light dust may be vacuumed.
General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Never put anything on top of the unit or block the air outlets.
Good and correct air flow is essential. Ensure cold air from the unit
does not re-bound off adjacent furniture back into the unit.
The unit will provide the best effect if all windows and doors
remain closed.
Do not use the unit where sunlight is shining directly onto it.
Moisture removed by the air conditioning process is passed to
the external condenser to be re-evaporated. However, in certain
conditions water may drip from condenser base. Take this into
account when siting.
The condenser unit MUST be sited externally. Make sure it is firmly
supported using suitable brackets/chains and must not be allowed
to hang by its flexible lines as this may cause serious damage.
Ensure the lines are free from kinks and severe bends.
The minimum size of extension cable that may be used is 2.5mm
up to a max length of 10metres. If extension cable is of drum type
please ensure it is COMPLETELY unwound otherwise serious
damage may occur.
Careful use of the thermostat will have to be observed. Excessive
and rapid turning between coolest and hottest settings will possible
blow the fuse or cause IRREPARABLE damage to the compressor.
Check condition of equipment before use. If unit is showing signs of
damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a standard
BS1363 domestic socket.
Always inspect plugs and leads for damage before plugging into the
supply - DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard , and
fully uncoiled when being used.
Laying Up
Clean surfaces
Clean filter
Stow condenser
Cover to keep clean
Fig. 4 Fig. 3
until the compressor stops. At this point the air conditioner
is set for automatic operation under the control of the
electronic thermostat to maintain the room temperature at
the pre-set value.
7. To stop the air conditioner press again the ON/OFF push-
button. (1).
Fan only
For this operation the outdoor unit can be placed either outside
(on the window sill or hanging on the wall) or Inside, attached to
the indoor unit.
The air conditioner is running In cooling mode.
1. Press the cooling push-button (2) to stop the compressor,
lamp (5) is released (deactivated).
2. Select the fan speed pressing the fan speed push-button (3).
Starting the air conditioner in fan only mode.
1. Switch on the air conditioner pressing the ON/OFF push-
button (1 ).
2. Make sure that the lamp (5) is released (deactivated).
3. Select the fan speed by pressing the fan speed push-
button (3).
Operating Instructions - PAC14
Click www.andrews-sykes.com 0800 211 611or Call Us Free
Getting started and operation
These units are supplied in two parts; a room unit and a
condenser. The room unit placed within area of being cooled
comprises of an evaporator and a compressor.
Before operating the unit, it should be positioned in the area to be
air conditioned so that it is in reach of a 13 A socket outlet and
where the condenser can be set up outside an opening window.
After unit is positioned, carefully remove the condenser from its
stowed position (fig.1). The chains and hooks are for supporting
the condenser. The flexible line connecting the condenser to the
unit will be stiff until operated (fig.2).
The room air enters the unit and once passed across the
evaporator is returned into the room as cooled air. The external
unit which is connected to the room unit by a flexible pipe,
contains the condenser which needs to be cooled by ambient
air, therefore the external unit needs to be positioned outside of
the room to be cooled.
The external condenser should never be positioned more than
1.5m above the level of the top of the room unit.
Cooling
Place the outdoor unit outside and insert the plug in the power
socket.
1. Twist the knob (4) of the thermostat to the right until you
reach the position of maximum cooling.
2. Switch on the air conditioner pressing the ON/OFF push-
button (1) lamps of last operations are displayed.
3. Select the cooling operation pressing the push-button
(2). lamp (5) lights.
4. Press the push-button (3) to select the high fan speed, the
lamp (6) lights.
5. When room temperature has reached the most suitable
value for your comfort, press again the push-button (3) to
select the low fan speed, the lamp (7) lights.
6. Now slowly twist the thermostat knob hack towards the left
Fig. 1
(If fitted) located on the rear of the unit refer to Fig.1
Fig. 2
4
3
2
8
7
Days of the week
Random function
indication
Recall function: To
disable and enable
the programs
Reset button
Time clock
Storage bracket
Flexible refrigerant line
External
condenser
Program storing 6
on programs, 6 off
programs
Current date and
time setting
Programs indication
Operating mode
indication auto
OFF - ON - AUTO
ON - OFF
Day of the week
starting (of group
of days)
Hours setting
Summer and winter
time indication
Minutes setting
1
5
6
Product specificaties
Merk: | Andrews |
Categorie: | Airconditioner |
Model: | PAC 14 |
Heb je hulp nodig?
Als je hulp nodig hebt met Andrews PAC 14 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airconditioner Andrews
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
11 September 2022
Handleiding Airconditioner
- Airconditioner Electrolux
- Airconditioner Bosch
- Airconditioner Samsung
- Airconditioner Panasonic
- Airconditioner LG
- Airconditioner AEG
- Airconditioner Bauknecht
- Airconditioner BEKO
- Airconditioner Daewoo
- Airconditioner Honeywell
- Airconditioner Inventum
- Airconditioner Toshiba
- Airconditioner Vaillant
- Airconditioner Whirlpool
- Airconditioner Zanker
- Airconditioner Zibro
- Airconditioner Acson
- Airconditioner Aermec
- Airconditioner Aertesi
- Airconditioner Aircool
- Airconditioner Aircooler
- Airconditioner Airlux
- Airconditioner Airview
- Airconditioner Airwell
- Airconditioner Akai
- Airconditioner Akira
- Airconditioner Alaska
- Airconditioner Alberello
- Airconditioner Amcor
- Airconditioner Argo
- Airconditioner Ariston
- Airconditioner Bryant
- Airconditioner D-Let
- Airconditioner Daikin
- Airconditioner Dimplex
- Airconditioner Domair
- Airconditioner Dometic
- Airconditioner Duux
- Airconditioner Edgestar
- Airconditioner Einhell
- Airconditioner Emerio
- Airconditioner Emmeti
- Airconditioner Eurom
- Airconditioner Fakir
- Airconditioner Frigor
- Airconditioner Fujitsu
- Airconditioner Galanz
- Airconditioner Gutfels
- Airconditioner H.Koenig
- Airconditioner Haier
- Airconditioner Handson
- Airconditioner Heiko
- Airconditioner Innova
- Airconditioner Kenmore
- Airconditioner Klarbach
- Airconditioner Klima1stKlaas
- Airconditioner Koenig
- Airconditioner Maiko
- Airconditioner MDV
- Airconditioner Mizushi
- Airconditioner Mobile Airco
- Airconditioner MPM
- Airconditioner MundoClima
- Airconditioner Qlima
- Airconditioner Qlima - Zibro
- Airconditioner Rowenta
- Airconditioner Shinco
- Airconditioner Sinclair
- Airconditioner SMD
- Airconditioner TechnoLife
- Airconditioner Telair
- Airconditioner Termozeta
- Airconditioner Thermo Comfort
- Airconditioner Tosot
- Airconditioner Trotec
- Airconditioner Ufesa
- Airconditioner Olimpia Splendid
- Airconditioner OneConcept
- Airconditioner Inventor
- Airconditioner Day
- Airconditioner Zymbo
Nieuwste handleidingen voor Airconditioner
18 Maart 2023
5 Februari 2023
5 Februari 2023
5 Februari 2023
2 Januari 2023
5 Februari 2023
4 Januari 2023
2 Januari 2023
8 Maart 2023