Zodiac Z900 Handleiding

Zodiac Pomp Z900

Lees hieronder de 📖 handleiding in het Nederlandse voor Zodiac Z900 (22 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/22
H0590800.A - 2017/05
More documents on:
www.zodiac-poolcare.com
Z900
Instruc ons for installa on and use - English
Heat pump
Transla on of the original instruc ons in french EN
1
EN
WARNINGS
Failure to respect the warnings may cause serious damage to pool equipment or cause serious injury, even death.
The appliance is intended to be used only for swimming pools and spas; it must not be used for any purpose other than that for
which it has been designed.
It is important that the equipment is operated by competent and quali ed (both physically and mentally) people who have
previously received the instruc ons for use. All persons not mee ng these criteria must not approach the appliance in order to
avoid exposure to dangerous elements.
Keep the appliance out of the reach of children.
The device must be installed by a quali ed technician according to the manufacturers instruc ons and in compliance with local
regula ons. The installer is responsible for installa on of the equipment and for compliance with na onal installa on regula ons.
Under no circumstances can the manufacturer be held liable in the event of failure to comply with applicable local standards.
Incorrect installa on and/or use may cause serious damage to property or serious injuries (possibly resul ng in death).
Any equipment, even carriage and packing paid, travels at the consignee's risk. The consignee should enter any reserva ons in
wri ng on the carriers delivery note, if there is any evidence of transport damage (and con rm them by recorded delivery le er
to the carrier within 48 hours). In the event of a device containing coolant fl uid that has been  pped over, issue your reserva ons
to the carrier in wri ng.
If the appliance suff ers a malfunc on, do not try to repair it yourself; contact a qualifi ed technician.
Refer to the warranty condi ons for details of the permi ed water balance values for opera ng the appliance.
Elimina ng or shun ng one of the safety devices automa cally voids the warranty, as does the replacement of parts using parts
not manufactured by ourselves.
Do not spray insec cide or any other chemical (in ammable or non-infl ammable) in the direc on of the appliance, as this may
damage the body and cause a fi re.
Heat pump, fi ltra on pump and fi lter appliances are compa ble with all types of water treatment.
Do not touch the fan and/or moving parts or insert a rod or your fi ngers in the vicinity of the moving parts while the appliance is
in opera on. The moving parts may cause severe injury, including death.
The electrical supply to the appliance must be protected by a dedicated 30 mA diff eren al residual current protec on device,
complying with the standards and regula ons in force in the country where it is installed.
Do not use an extension cord to plug the appliance into; plug it directly into a proper wall socket or outlet.
Before carrying out any opera ons, check that:
- The voltage indicated on the maker's plate of the appliance corresponds to the mains voltage,
- The power grid is adapted to the power requirements of the appliance, and is properly grounded.
- The plug (where applicable) is suitable for the socket.
In the event of abnormal func on or the release of odours from the appliance, turn it of immediately, unplug it from its power
supply and contact a professional.
Before any access to the appliance for any required service or maintenance, ensure that it is switched off and disconnected from
the power supply. In addi on to any other equipment connected to the appliance, and that the hea ng priority (where applicable)
is deac vated.
Do not disconnect and reconnect the appliance to the power supply when in opera on.
Do not pull on the power cord to disconnect it from the power supply.
Do not a empt to carry out any service or maintenance with wet hands or while the appliance is wet.
Clean the terminal board or the power supply socket before connec on.
For any component or sub-assembly containing a ba ery: do not recharge or dismantle the ba ery, or throw it into a fi re. Do not
expose it to high temperatures or direct sunlight.
In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.
Do not immerse the appliance in water (with the excep on of cleaners) or mud.
Do not discharge R410A or R407C uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered by the Kyoto
Protocol, with a Global Warming Poten al (GWP) = 2088 for R410A (Direc ve EC 842/2006).
According to French decree No. , if the appliance has more than 5teq CO2 of refrigerant gas (refer to manufacturer 2015-1790
specifi ca ons), the cooling circuit must be checked for leakage at least once a year. This opera on must be carried out by a cer ed
cooling appliance specialist.
The heat pumps comply with Direc ve 2014/68/EU (PED) via Annex III, Module D1, and cer ed as such by the third-party,
independent No ed Body, ICIM No. 0425.
Addi onal considera ons in rela on to this Direc ve
Installa on and maintenance
The unit may not be installed close to combus ble materials, or the air duct inlet of an adjacent building .
With some devices, it is essen al to fi t protec on grids if the unit is installed in an area with uncontrolled access.
During installa on, troubleshoo ng and maintenance, pipes may not be used as steps: the pipe could break under the weight, spilling
refrigerant and possibly causing serious burns.
When servicing the appliance, the composi on and state of heat carrying uid must be checked, as well as the absence of any
refrigerant.
During the annual unit sealing test in accordance with applicable legisla on, the high and low pressure switches must be checked to
ensure that they are securely fastened to the coolant circuit and that they cut-off the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around cooling components.
Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi ng the temperature and pressure
sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high pressures with the
consequent risk of severe scalding.
Troubleshoo ng
All soldering work must be carried out by a someone quali ed to do so.
Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.
Leak detec on, pressure test:
- never use oxygen or dry air, risk of fi re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informa on plate,
- the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A) in the case the device is
equipped with the op onal pressure gauge.
The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1’’5/8. A cer cate as indicated in
§2.1 in compliance with standard NF EN 10204 will be requested from the supplier and fi led in the facility's technical documenta on.
Technical data rela ve to the safety requirements of the various applicable direc ves must be indicated on the informa on plate.
All this informa on must be recorded in the unit's installa on manual, which must be kept in the technical le of the unit: model,
code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturers address, refrigerant and weight,
electrical parameters, thermo-dynamic and acous c performances.
Recycling
This symbol means that your appliance should not be disposed of with other rubbish. It should be selec vely sorted so that it
can be re-used, recycled or transformed. If it contains any substances that may be harmful to the environment, these will be
disposed of or neutralised.
Contact your retailer for recycling informa on.


Product specificaties

Merk: Zodiac
Categorie: Pomp
Model: Z900

Heb je hulp nodig?

Als je hulp nodig hebt met Zodiac Z900 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Zodiac

Handleiding Pomp

Nieuwste handleidingen voor Pomp

Sauermann

Sauermann Omega Handleiding

13 November 2024
Sauermann

Sauermann Delta Handleiding

12 November 2024
Testo

Testo 565i Handleiding

12 November 2024
Simpson

Simpson SCP71008 Handleiding

11 November 2024
MSW

MSW -OP-56-DC Handleiding

5 November 2024
MSW

MSW -FM-N-53 Handleiding

4 November 2024
MSW

MSW -AOP40S Handleiding

15 Oktober 2024
MSW

MSW -MN34M Handleiding

15 Oktober 2024
MSW

MSW -MN34 Handleiding

15 Oktober 2024