YA-MAN Medi Lift Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor YA-MAN Medi Lift (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Adjustthemasktopositionsofyoureyes,
noseandmouth.
Itwillbemoreeffectivetowearamaskwhen
youarelookingupwardandconcernedpartsof
yourmouthandfacecontoursarelifted.
ThankyouforpurchasingYA-MANproduct.
 CarefullyreadthisUsersManualtousethedeviceproperlyandsafely.
Afterreadingthecontentshereof,makesuretostorethisUsersManualinanaccessiblelocation.
 MakesuretoincludethisUsersManualifyouaretransferringownershipofthedevicetoanotherperson.
Accessories
DonotusethiscableforproductsotherthanMediLift.
Designandspecificationsofthemainunitandaccessoriesaresubjecttochangeforimprovementpurposes
withoutanynotice.
Controller
Front Rear
Attachment
GuidelineMark
ChargingTerminal(Micro-USB
Electrode
Lamp
(POWER)/ MODE
Button
Button
Button
SiliconeMask
Front
Rear Electrode
StopperBand ][1
StopperBand ][3
StopperBand ][2
StopperBand ][4
AttachmentGuidelineMark
AutoPowerO
Thedevicewillautomaticallyturnoffapprox.10minutesafterithasbeenturnedonandthemodewasset.
Ifyoushiftfromonemodetoanotherwhileusingthedevice,thepowerwillturnoffapprox.10minutesafteryou
havechangedtothenewmode.Becarefuloftheoperatingtime.
Functions
Attachtwocontrollersonthesiliconemask
Wearingasiliconemask
Chargingthebattery
Ifthereisanywaterdropletonthecontrollersandchargingterminal,makesuretowipedry.
Chargingwhilewaterdropletsareremainingonthedevicecouldcauseafailure.
Whenchargingthebatteryforthersttimeafterpurchasingtheproduct,usethedeviceonlyafterthebatteryisfullycharged.
Whenusingtheproductforthersttimeorwhentheitemhasnotbeenusedforanextendedperiodoftime,
 thedevicemayonlyoperateforashortperiodoftimeevenafterthe lampsstoppedashing.
 Insuchacase,chargethecontrollersagainbeforeusingit.
UseonlytheenclosedchargingUSBcable.
※Thecontrollersmaynotbechargedproperlywithotheritemsonthemarket.
ChargingUSBCable
Controller(right)
Controllerleft)
Makesurethecontrollersarefacingtherightdirection.
12
3
5
4
Howtoapplytreatment
Useamirrorwhenyouareusingthedeviceuntilyougetusedtoit.
4
1Turnonthepower
2
3SelectyourchoiceofEMSlevel(intensity)
4Turningoffthedevice
Thedevicewillautomaticallyturnoffapprox.10minutesafterthemodeisselected.
Thedevicewillautomaticallyturnoffapprox.
10minutesafterthemodeisselected.
 
 
 
Stretchoutthesiliconemaskandpushoutthecontroller.
Donotexcessivelystretchthemask.
Itmaycauseadamagetothesiliconemask.
Howtodetachacontrollerfromthesiliconemask
Howtocleanthecontrollers
1Wipeoffanydirtusingawellwrungsoftclothorsimilarmaterial
Forstubborndirt,wipegentlywithaclothsoakedinadilutedneutraldetergent.
Whencleaningthedevice,
besuretoturnoffthedevice
Maycauseanelectricshock,
shortcircuitorafire.
Donotwashwithwater
Thisdeviceisnotwater-proof.
Maycauseafailureofthedevice.
Donotstoreorleavethedevicewithlotion,serumorgeladheringtothedevice.
Neverusealkalinedetergent,alcohol,thinner,ornailpolishremover.
Cleanthedeviceaftereachuseforahygienicreason.
Removethecontrollersfromthesiliconemask.
Howtocleanthesiliconemask)
1Washyourupperinnerarmwithasoapandwipedrywithatowel
Donotstoreorleavethesiliconemaskwithlotion,serumorgeladheringtothemask.
Donotusehotwater.
Neverusealkalinedetergent,alcohol,thinner,ornailpolishremover.
Cleanthesiliconemaskaftereachuseforahygienicreason.
Removethecontrollersfromthesiliconemask.
3
NamesandFunctionsofComponents
BeforeUse
HowtoUse
AfterTreatment
Lamp
Lamp
5
[1][2]
[3][4]
2Applyoil-freegelonwashedskinandholdthecontrolleronyourupperarm.
Makesurethreeelectrodesareincontactwithyourskin.SelectAuto-mode
andLevel1(theminimum)withanotherhandanduseitforapprox.3minutes
Testthesiliconemaskinastatuswiththecontrollersattached.Closelyattachthethreeelectrodes
onthebackofeitherrightorleftsideofthesiliconemasktoyourskin.
ThecontrollersaresettoAuto-modeandtheEMSlevel(intensity)issettoLevel1(theminimum)
bydefaultwhenturnedon.
Forhowtouse,refertothesectionʻHowtoapplytreatmentʼ.
3Wipeoffgelandcheckthatyourskinshowsnoabnormality
Continuetousetheproductonlyifyourskinexperiencenoabnormalitysuchasreddeningor
burningsensationonyourskinwithin24hours.
Right
Right Left
Left
Makesuretoperformapre-testinordertopreventskinproblemsfromoccurring.
Ifarash,reddening,itch,stingingsensation,orotherabnormalityoccursatthepre-testingsite,
immediatelystopthepre-test.
Donotusethedeviceifaskinabnormalityisperceived.
Werecommendusingthedeviceapprox.onceaday.
Toretain
Householdbeautydevice MediLift EP-14
PleasereadSafetyPrecautionsonthebacktheofthispagetousethedevicesafely.
©2018 YA-MAN  LTD. ALL  RIGH TS R ESE RVED .Unauthorizedcopyingandreplicationofthecontents,textandimages
ofthisUser'sManualarestrictlyprohibited.
EP14-1-001E
Pre-testingonskin
Whenusingthedeviceforthefirsttime,alwaystestfirstforcompatibilitywithyourskin.
YoucannotfeelEMS?
Isthereanybilateraldifferencein
feelingofEMSsensation?
Introduction
User'sManual
Checkbothrightandleftcontrollers
tomakesurethatthelamps
aredirectingupward.
Alignattachmentguidelinemarkson
thecontrollerandthesiliconemask.
Theninsertacornerofthecontroller
intoachaseofthesiliconemask.
Turninsideoutthesiliconemask.
Besurethattheelectrodes
ofthesiliconemaskandcontrollers
arealigned.
Holdanedgeofthecontrollerwith
yourthumbandsqueezethecontroller
intounderneathofthemasktosetitfirm.
Settheothercontrollerfollowing
thesamestepsdescribedabove.
Checkagaintomakesurethatthelampsofbothrightandleftcontrollersaredirectingupward.
Attention
Attention
Wearingasiliconemask
Afterremovingmake-upandwashingyourface,applyyourlotion,serumorgeltomoisturizeyourskinthoroughlybeforeuse.
Youcanwearthesiliconemaskaboveasheetmask.
EMScurrentwillnotbecarriedifthereisnotenoughmoisturebetweentheelectrodessetonthesiliconemask
andtheskin.Makesurethereisalwaysenoughmoisture.
※Donotusecosmeticswhichcontainoilsuchasanoil-basedserum.Itmaycauseadeteriorationofthesiliconemask.
※Beawarethatwhenhighlyviscousgelandcosmeticsgetthroughachargingterminalofthecontrollers,
itmaycauseafailureofthedevice.
21
Becarefulnottoadheregeltothecontrollers,
particularlyonthechargingterminals.
Makesuretoapplygelonthesiliconemask
afterthecontrollersareattached.
Donotgiveexcessivepressuretothesiliconemaskwhileattachingthecontrollerstoit.
Itmaycauseadamagetothesiliconemask.
Donotpressanybuttonofthecontrollerswhenyouattachthemtothesiliconemask.
Attachthecontrollersonthesiliconemaskwhiletheirpowersareturnedoff.
Turninsideoutthesiliconemaskandapplyappropriate
amountofgelonitselectrodes
(totalof6pointsonrightandleftcontrollers
).
Headshapesvaryfromindividualtoindividual.
Holdthestopperbandwhereitfirmlystaysinitsposition
withoutsliding.
Becareful
nottotangle
hairinthe
siliconemask
Fitthesiliconemasktoyourface.
Becareful
withclamping
Becareful
withtwistingof
stopperbands
Pulltheupperstopperbands[1]and[2]obliquelyupward
asifyouarecoveringyourears.Tightenthehook-and-loop
fastenerstoholditfirmintheposition.
Insomecases,thesiliconemaskmaynotcloselyfit
toyourfaceanditmayappeartooloosedueto
afaceshape.However,ifthesixelectrodesonright
andleftcontrollersareallproperlyincontactwith
theskin,thedeviceisabletooperateatreatment.
Becarefulnottocoverthecontrollers.
Ifstopperband[3]or[4]areexcessivelytightened,
thereisadangerofcompressinganeck.
Whenyourupperstopperband[1]and[2]are
infixedstatusandthesixelectrodesonbothright
andleftcontrollersareproperlytouchingyourskin,
youcanusethemaskwithoutfixing
thelowerstopperband[3]and[4].
Pullupthelowerstopperbands[3]and[4]along
yourjawlinetowardstopofthehead.Tighten
hook-and-loopfastenerstoholditfirmintheposition.
Becareful
withclamping
Checkonamirrorthatthesiliconemaskproperlyfits
toyourface.
Skinmoisturelevelmaybeinsufficient
Moisturizewellyourskinwhereincontactwiththe
siliconemaskwithlotion,serumorgel.
Thedifferenceinskinmoisturelevelofrightandleft
sidesofyourfacemayaffectthefeelingofsensation.
Thereisspacebetweenthecontrollersand
thesiliconemask.
Ifthereisspacebetweentheelectrodesand
thesiliconemask,EMSwillnotflowthroughtheskin.
Checkiftheelectrodesareproperlyattachedto
thesiliconemask.
Attention
Besuretoattachthecontrollerstothesiliconemaskbeforewearingit.
Wearthesiliconemaskwhenitspoweristurnedoff.
Wearthesiliconemaskwithyourhairbeingtiedup.
Becarefulnottogetyourhaircaughtbyhookandloopfastenersofthesiliconemaskwhenyouwearit.
Besuretheelectrodes(atotalofsixontherightandleftcontrollers)onthebackofthesiliconemaskareincontact
withskin.Ifthecontactbetweentheelectrodesandtheskinistooloose,youmaynotbeabletogaintheeffectofEMS.
Whenyouusehighlyviscousgelorothercosmetics,beverycarefulnottoletthemgetthroughintothecharging
terminalswhileyouareattachingorremovingthecontrollers.
Besuretousetheproductafteryourhairbecomesdry,whenyouputoil-basedleave-intreatmentsonyourhair.
Besurethereisalwaysenoughmoisturesuchaslotion,serumorgelbetweenyourskinandtheelectrodes.
Ifthereisnotenoughmoisture,EMStransmissionbecomesinefficientandmaycausedecreasedeffectsorskintroubles.
Press(POWER/MODEbuttonoftherightandleftcontrollersforasecondormoreatthesametime.
Abeepwillsoundandthelampwilllightuppurple.
ThemodeissettoAuto-modeandtheEMS(intensity)levelissettoLevel1(theminimum)
bydefaultwhenturnedon.
Besurethatyouarewearingthesiliconemaskwiththecontrollersattachedwhenyouareturningonthedevice.
Tostopthedeviceduringitsoperation,
press(POWER)/MODEbuttonoftherightandleft
controllersforasecondormoreatthesametime.
Selectyourchoiceofmode
Press(POWER/MODEbuttonoftherightandleftcontrollersatthesametime.
Eachtimeyoupressthebutton,themodewillshiftwithabeep.
Thelampwilllightuppurple.
Stretch-modeandUp-modewillautomatically
shiftalternately.
Whenthemodeshifts,afeelingofelectric
sensation(EMS)changes.Youcanadjustto
yourpreferredEMSlevel(intensity)depending
onthesituation.
Thelampwilllightupblue.
Givesanelectricstimulation(EMS)between
electrodepoints①↔②.
Thelampwilllightupred.
Givesanelectricstimulation(EMS)between
electrodepoints①↔③.
Up-mode red
Auto-modepurple
Stretch-mode blue
Press/buttonsofrightandleftcontrollersatthesametime.
Youcanselectamong6levels(intensity)ofEMS.
Thealertwillsoundas“beep,beep,beep,whenyourselectedlevelreachesto
Level1(theminimum)orLevel6(themaximum).
Beep Beep,
beep
ButtonButton
Level 1 2 3 4 5 6
Beep,
beep,
beep
Beep,
beep,
beep
(min) (max)
Weak Strong
Attention
AlwaysselectLevel1(theminimum)ifitisyourfirsttreatmentoruntilyoubecome
accustomedtotheoperationandtreatment.
Ifyourskinbecomesdry,youcanaddmorelotion,serumorgel.
Turnoffthepowerandtakeoffthesiliconemaskbeforeapplyingextramoisturizer.
DonotraiseEMSlevel(intensity)tothepointwhereyoufeeltinglingpain.
Tostopthedeviceduringuse,press(POWER)/MODEbuttonoftherightandleftcontrollersfor
asecondormoreatthesametime.
Thedevicewillautomaticallyturnoffapprox.10minutesafterthemodeisselected.
Theabovedurationandfrequencyareonlyaguideline.Usethedeviceappropriatelybasedonyourskinconditions.
Ifyounoticeanythingunusualaboutyourskinduringorafteruse,stopusingthedeviceimmediately.
Whenusingthedevicecontinuously,pleaseleaveanintervalof5hoursormorebetweentreatments.
Caution
Warning
Caution
Caution
1Removethecontrollersandwashthesiliconemask
withwarmwater
Forstubborndirt,wipegentlywithaclothsoakedin
adilutedneutraldetergent.
2Wipeoffanymoisturewith
dryclothsuchasatowel
Wipetheelectrodesthoroughlytoensure
thatnomoistureorgelremains.
3Drythesiliconemask
inalocationwithgoodventilation
Leavingthedevicewithoutremovingdirtor
moisturemaycausemold,discolorationorodors.
ChargingUSBCable(Micro-USB)User'sManual
Chargingwillbeginonceyouconnectcontrollerstoanelectronicpowersupplyasshownonadiagram.
lampswillflashpurpleduringacharge.
Whenchargingiscomplete,thelampwillturnoff.UnplugachargingUSBcable.
Atanindoortemperatureofapproximately25℃,itwilltakeabout1.5hourstoreachafullcharge,
atwhichthedevicecanoperateforabout5hours.Actualchargingtimeandoperatingtime
willdifferdependingupontheremainingpowerandthechargingenvironment.



Maycauseanelectricshock,shortcircuit,ignition,orafailureofthedevice.

Maycauseanelectricshock,shortcircuit,oraignition.
Thissymbolshowsyouwhatyoumustdo.
Thissymbolshowsyouwhatyoumustbecarefulwith.

Useofthedevicecouldcauseanelectronicmedicaldevicetomalfunction.
◆Personsusingelectronicmedicaldevices
Pacemakerorotherimplantedelectronicmedicaldevice,artificialheart-lungmachineorotherelectronic
 life-supportmedicaldevice,electrocardiographorotherelectronicmedicaldeviceswornonthebody.
 



Maycauseanaccidentorotherproblems.
Maycauseaninjuryorafailureofthedevice.

Maycauseaninjuryorafailureofthedevice.

Ifyouhavenotusedthedeviceforanextendedperiod,inspectitcarefullyandcheck
thatthedeviceworksproperlyandsafelybeforeuse.
Ifthedeviceismalfunctioning,gotoʻTroubleshootingʼandattempttoidentifytheproblembeforearrangingto
havethedevicerepaired.Iftheproblempersists,contactyourlocaldistributor.
Ifthedevicemalfunctionsorappearsdamaged,pleasecontactyourlocaldistributor.
Storeinaclean,well-ventilatedplaceoutofthereachofchildren.
RemovethechargingUSBcablefromthecontrollersandtheUSBportwhennotinuse
foralongtimeandstorethemsafely.
Donotleaveinhotorhumidplaces,suchasnearflame,inbrightsunlight,orinabathroom.

 Ifyouperceiveanyabnormalitywhileusingthedevice,verifythefollowingpointsbeforearranging
tohavethedevicerepaired.
Runoutofpower.Chargethebattery.

Thedeviceisnotwaterproof.
Donotusethedeviceinthebathroom.
Donotusethedeviceduringyoursleep.
Werecommendusingthedeviceonceaday,
forapprox.10minutes.Whenusingthedevicecontinuously,
pleaseleaveanintervalof hoursormorebetweentreatments.5
Mostpeoplehaveasymmetricalfacesandmayfeeluneven
stimulationonrightandleftsidesoftheirfaces.
AdjustEMSlevelofrightandleftcontrollers.
ThisisduetothestimulationofEMS.Ifyoursymptoms
persistformorethanaday,consultadoctor.
ThisisduetothestimulationofEMS.Stopusingthedevice
untilyourfacialdiscomfortisgone.
Youmayfeeltoothpainwhenyouareundergoing
dentaltreatmentorhavingsilver-crownedtooth.
Ifyoufeelasenseofdiscomfort,pleaseconsultadoctor.
Donotwearthemaskduringpregnancyorsoonafterdelivery.
Pleaseconsultyourprimarycaredoctor.
Itmaycauseaninflammation.Ifyouexperienceanyskintrouble,
immediatelystopusingthedeviceandconsultadoctor.


Contactyourdistributorforanyquestionyoumayhaveregardingthewarrantythatappliestothedevice,
repairsofthedevice,orothermattersrequiringclarification.

DC V 5 0 .5 A
ChargingUSBcable(Micro-USB)One
User'sManual
Siliconemask:silicone
Controller:polycarbonate
Siliconemask:approx.112g
Controller:approx.17g(onepiece)
Siliconemask:approx.W600 180×H (mm)
Controller:approx.W50×H50×D15(mm)
Maximumapprox.1.5W(whencharging
10 40℃
Lithiumionbattery
Approx.1.5hours※Mayvarydependingonthechargingenvironment.
Approx.5hours(whenfullycharged)
※OperatingtimemayvarywithconditionsofuseandEMSlevel.



Siliconemask:China
Controller:Japan
Carefullyreadtheseʻ ʼbeforeusingthedevice.SafetyPrecautions
Sensiblyusethedeviceinaccordancewiththeprescribedsteps.
Ifanyabnormalityarises,immediatelydiscontinuetheuseofthedeviceandarrangetohavethedevicerepaired.
Donotusethedeviceinadefectivestate,asdoingsocouldcausephysicalharmtotheuser.
PrecautionslistedintheUserʼsManualareveryimportant.Foryoursafety,pleasefollowthemcarefully.
PrecautionsareclassifiedasDanger,Warning,Cautioninordertoclearlyspecifythelevelandurgencyof
dangerandpossibleinjuryordamagethatmayoccurifthedeviceismisused.





Byfailingtoproperlyoperatethedeviceaccordingtothistypeofprecaution,
itisexpectedthatahazardthatcouldcausethedeathorseriousinjury
ofanindividualwillimminentlyarise.
Byfailingtoproperlyoperatethedeviceaccordingtothistypeofprecaution,
ahazardthatcouldcausethedeathorseriousinjuryofanindividualmightconceivablyarise.
Thefailuretoproperlyoperatethedeviceaccordingtothistypeofprecaution
couldconceivablycauseaninjurytoanindividualorpropertydamagetooccur.
※“Propertydamage”referstoexpandeddamageaffectingadwelling,householdbelongings,ordomesticanimalsandpets.
Thissymbolshowsyouwhatyoumustnotdo.





Thoseundergoingtreatmentbyadoctor,thoseinaphysicalgrowthstage,thosewithacutemedicalconditions,
tubercularconditions,feverorhighbloodpressure.
Thosewithcommunicablediseases,malignanttumors,diseasesofblood,internalorgans,skinconditions,
allergiesoratopicdermatitis.
Thosewithskinproblems,sensitive/weakskin,orpathologicalpigmentationontheskinduetophysicalstimulationorothercauses.
Thoseexperiencingseverefatigue,thoseinpoorhealth,intoxicatedpersons,pregnantwomen,
womenduringtheirperiodorbreastfeedingmothers.
Thosetakingmedicationsthatcausedrowsiness.
Thosehavingcapillarydilatationduetolong-termuseofsteroidhormonaldrugsoraliverdisorder.
YoumayfeelanunpleasantsensationwithEMSifyouhaveteethfillingsorarehavinganydentaltreatment.
Choosealowerintensitylevelandapplythecontrollersonadifferentarea.








Maycauseanaccidentorinjury.

Maycauseanaccidentorinjury.


Maycauseanaccidentorinjury.

Maycauseaninjuryorafailureofthedevice.

Maycauseanaccidentorotherproblems.
※Ifyouareuncertainastowhetheritissafetousethedevice,consultadoctorpriortouse.
 
Maycauseaninjuryorfever.

Maycauseaninjuryorafailureofthedevice.

Maycauseaninjuryorafailureofthedevice.
Facialareaswithcutsorthathaveundergonecosmeticsurgery,insidethemouth,oronmucousmembranes,
skinirritationorrednesscausedbyexcessivesunburn.
Facialareasthatarepartsinamedorsuppuratedduetoacneorskininfection,itchyorhaveaburningsensationorswollenmoles.
Viralwarts,Adamʼsapple,eyeballsoreyelids.

Maycauseadamageorignitionofthedevice.

Maycauseafire,electricshock,orinjury.
Contactyourdistributorforadviceonrepairingthedevice.






Maycauseaninjury.

Maycauseaninjury.




Maycausepotentialskinproblemssuchasscarsorworseningofsymptoms.

Maycausedamagetothesurfaceofthedevice.


Maycauseaninjuryorafailureofthedevice.



Maycauseafailureofthedevice.


Iftheconditionpersiststhenextday,consultadoctor.



Maycauseanelectricshock,shortcircuit,ignition,orbreakofthecables.


Maycauseanaccidentorinjury.Usethedeviceappropriatelybasedonyourskinconditions.

Donotcontinuetouseinsuchconditionsasthismaydamageyourskin.

Maycauseafailureofthedeviceorskinproblems.


Maycauseanelectricshock,shortcircuit,ignition,orafailureofthedevice.



Maycauseanelectricshock,shortcircuit,orignition.

󱐯󱐯
TransferofEMSmaybecomedifficultifthereisnotenoughmoisture.
Maycausedeteriorationineffectivenessorskinproblems.

Maycauseanaccident,injury,orafailureofthedevice.
Donotusethedevicemorethanasettime.
Usethedeviceappropriatelybasedonyourskinconditions.
Donotusethedeviceifyourskinisexperiencingarash,inflammation,itchiness,orotherabnormalities.
Donotusethedeviceontheskinaftersunbathing,togetherwithpeelingorothertreatments.





DonotplaceheavyobjectsontopofthechargingUSBcable,
orallowthemtobeputinbetweenobjects.
MaydamagethechargingUSBcabletocauseareorelectricshock.




Maycauseanelectricshock,shortcircuit,orignition.
Contactyourdistributorforadviceonrepairingthedevice.


󱐯


Maycauseanelectricshock,shortcircuit,orignition.
󱐯
Donotusethedeviceifmalfunctionoccurs;smoke,anabnormalnoise,oranodorisdetectedor
ifitisotherwiseoperatinginanabnormalstate.


Maycauseafire,anelectricshock,orafailureofthedevice. 
TheenclosedUSBcableisonlyforcharging.




Thedevicefeaturesabuilt-inrechargeablebattery.Maycauseanoverheating,ignition,explosionormalfunction.


 










PressthePOWER/MODEbuttonforapprox.1second.
Lowbattery.Chargethebattery.
Batterylifeended.Contactyourdistributor.
Yourskinisdry.Moisturizeyourskinwithlotion,serumorgelbeforeusingthedevice.
ConnectthechargingUSBcabletotheUSBport.
ConnectthechargingUSBcabletothemainunit.
DecreaseEMSlevelwith()button.
Theelectrodesmaynotbeproperlyintouchwithyouskin.
Wearthesiliconemaskproperly.
RaiseEMSlevelwith()button.
Yourskinisdry.Moisturizeyourskinwithlotion,serumorgelbeforeusingthedevice.
Thedevicewillautomaticallyturnoffapprox. minutesafterthemodeisselected.10







󱐯









Werecommendusingthedeviceapprox.
10minutespertreatment.
※Thedevicewillautomaticallyturnoffapprox.
 10minutesafterthemodeisselected.
※Theabovedurations/frequenciesareonlyaguideline.
 Usethedeviceappropriatelybasedonyourskinconditions.
Ifyouperceiveaskinabnormality,immediatelystopusing.
Asauniquefeatureofthisproduct,
moreyouapplywater,lotionorserum,
moreyouwillfeelEMS.Ifthereisinsufficient
moisture,youmayfeeltinglingsensation.












Therechargeablebatteryisaconsumableitem.
Ifthedevicenolongeroperatesformorethanashortperiodoftimeevenafterthebatteryhasbeenrecharged,
thebatterymayhavereachedtheendofitsservicelife.(Thebatteryisexpectedtolast300chargecycles.)
Ifyouneedbatteryreplacement,contactyourlocaldistributor.
Followyourlocalgovernmentrulesforproperdisposalofthisproduct.
Thisproductusesalithiumionbattery.



Product specificaties

Merk: YA-MAN
Categorie: Niet gecategoriseerd
Model: Medi Lift

Heb je hulp nodig?

Als je hulp nodig hebt met YA-MAN Medi Lift stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd YA-MAN

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024