TOOL-BOX is a collection of six useful synthesizer utilities. This module includes a two input
voltage summing section, a signal rectier, bipolar comparator, analog OR (maximum), an
inverter, and a voltage controlled toggle switch. TOOL-BOX provides the tools required for
spicing up your patches as well as some of the typically overlooked utilities missing from most
modular systems.
SUM INPUTS
These are the inputs to the SUM section. Apply a signal to the A and B inputs to add
them together. Both audio and control voltages (CV) are accepted.
IN OUT
SUM SUM
IN
REC
OUT
REC
L2
OUT
CMP
IN
CMP
L4
OUT
OR
IN
OR
IN
INV
OUT
INV
L5
L6
OUT
SW
IN
SW
CV
SW
SEL
SW
L7
LED INDICATOR
INPUT
OUTPUT
MODE SELECTOR
COLOR KEY LEGEND
IN
SUM
SUM OUTPUT
This is the SUM output.
OUT
SUM
L1 SUM LED
This LED indicates the signal polarity of the SUM output. BLUE is positive, RED negative.
RECTIFIER INPUT
Apply a signal with a negative polarity component to this input. The negative portions
of the signal will be ipped’ or rectied into the positive polarity region.
IN
REC
RECTIFIER OUTPUT
This is the output of the RECTIFIER
OUT
REC
L2 RECTIFIER LED
Indicates the amplitude level of the original, positive, and rectied portions of the output.
COMPARATOR INPUTS
This section produces a positive pulse/gate when the input signal reaches the threshold of
either of the inputs. A DC voltage can be applied with an oset generator (like the S.P.O.) to set
a static threshold on either input and a dynamic voltage can be applied to the other input. If
only one input is used, the default threshold is set to 0V. Two dynamic voltages can also be
used for interesting pulse variations that occur whenever the two voltages match in value. The
comparator output can be used to trigger the toggle switch contained within TOOL-BOX or
used to gate other modules like envelope generators, drum synths, or as a clock source.
IN
CMP
COMPARATOR OUTPUT
This is the pulse output of the COMPARATOR.
OUT
CMP
L3 COMPARATOR LED
This LED indicates the pule/gate activity of the COMPARATOR.
ANALOG OR INPUTS
ANALOG OR is also known as a voltage maximum. Two signals are applied to these
inputs. The two inputs are processed so that only the current maximum values of the two
signals passes to the output.
IN
OR
ANALOG OR OUTPUT
This is the output of the ANALOG OR.
OUT
OR
L4 ANALOG OR LED
This LED indicates the output amplitude activity of the ANALOG OR.
INVERT INPUT
Use this input to invert (ip the polarity) of a signal. All signals are accepted.
IN
INV
INVERT OUTPUT
This is the output of the INVERT section.
OUT
INV
L5 INVERT LED
This LED indicates the output amplitude and polarity activity of the INVERTER.
SWITCH INPUTS
Apply any type of signal to these inputs and use control voltages (CV) or the A/B SEL
button to toggle between which input passes to the output.
IN
SW
SWITCH OUTPUT
This is the output of the SWITCH.
OUT
SW
L6 SWITCH POSITION LED
This LED indicates the current switch position.
L7 SWITCH SELECT LED
Indicates the status of the A/B SEL button and/or CV that is activating the SWITCH.
SWITCH CV INPUT
Apply an approximately 0-5V (0V=A, 5V=B) control voltage to this input to toggle the SWITCH.
CV
SW
SWITCH A/B SELECT
Use this button to manually toggle the SWITCH.
SEL
SW


Product specificaties

Merk: WMD
Categorie: Niet gecategoriseerd
Model: SSF Tool-Box

Heb je hulp nodig?

Als je hulp nodig hebt met WMD SSF Tool-Box stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd WMD

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024