Pagina 1/4
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03983 01 2410
03983 - Connected 3in 1out module
VIEW WIRELESS SMART HOME
The retrofit connected relay module is equipped with 3 SELV programmable digital inputs and 1
programmable NO/NC SELV relay output; specifically:
• P, IN1, IN2 are inputs for voltage-free contacts with the following functions:
- P (only connected to a push button): configuration, reset or activation of the on-board relay;
- IN1 and IN2: activation of up to 3 scenarios, depending on the combination of inputs 0-1,
1-0, 1-1 (excerpt for case 0-0);
- IN1 and/or IN2: activation of push notifications, control of a group of lights/roller shutters with
1 input/various or interface with sensors to send their status.
N.B. for roller shutters use push buttons art. xx062 and xx066.
• Relay output with voltage-free contact which, regardless of the input configuration, can be
configured in “Lights”, “Accesses” and “Various” applications.
Download the View Wireless App from the stores onto the tablet/smartphone you
will be using for configuration.
When the device is powered for the rst conguration, we recommend you search for any new
rmware and perform the update.
You will also need:
Gateway art. 30807.x-20597-19597-14597
View App for management via smartphone/tablet
Amazon Alexa, Google Assistant, Siri (Homekit) voice assistants for possible voice
operation.
CONFIGURATION IN
1. Create your Installer account on MyVIMAR (on-line).
2. Wire all the devices in the system (2-way switches, relays, thermostats, gateway, etc.).
3. Start the View Wireless App and log in with the credentials you just created.
4. Create the system and the environments.
5. Associate all the devices with the environments, except for the gateway (which should be
associated last).
To associate the relay module:
• Select “Add” ( ), choose the environment to place it and give it a name
• Select ; activate the Bluetooth connection on your tablet/smartphone and approach the
relay module
• Press the push button connected to P and set the desired function
6. For every device, set the function, the parameters and any accessory devices (wired or radio
control and related function).
7. Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.
8. Transfer the system to the Administrator user (who must have created his/her profile on
MyVIMAR).
For details, see the View Wireless App manual that can be downloaded from the www.
vimar.com website.
CONTROLLABLE LOADS.
• Voltage-free contact output, SELV (to operate only low voltage loads such as gates/locks/
solenoid valves).
- 4A AC-1, 12/24 VAC
- 4A DC-1, 12/24 VDC
- 0.8A DC-13, 24VDC
AC-1, DC-1 and DC-13 represent standardised duty categories that establish the current
values that the output must be able to withstand (according to IEC 947 standard).
RESETTING THE 03983 MODULE.
The reset restores the factory settings. Within the first 5 minutes from powering, press the push
button connected to P for 30 s until LED flashes white.
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country where the
products are installed.
• The relay output is SELV type.
• Installation must be carried out with the system switched not powered.
• The device can be installed in flush mounting boxes only in correspondence with 2 adjacent
blank modules.
• The input conductors can be extended up to a maximum of 20 m with a cable featuring
double insulation and a minimum cross-section of 0.22 mm
2.
• In Access Control systems, envisage a door opening emergency mode in the event of a
power failure.
IMPORTANT: The SELV circuit conductors are insulated for a rated voltage of 300 V (UL 1061
standard) and they can therefore co-exist with the conductors powered with up to 230 V~.
When making the connections you must be careful to maintain the insulation between the SELV
circuit and the dangerous voltage circuits as required by the installation regulations.
CHARACTERISTICS.
• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Dissipated power: 0.60 W
• RF transmission power: < 100mW (20dBm)
• Frequency range: 2400-2483.5 MHz
• Terminals: 2 (L and N) for phase and neutral;
• Inputs:
- P controls the relay output directly, setting the device to configuration mode during
enrolment and enabling its reset.
- IN1, IN2 to call up a scenario or for DND signalling via bipolar 1-way switch 30016.x-
20015.0-19015.0-14015.0+ XX026.DND+ 00936.250.X in case of “relay change-over” with
landing reader xx462.
For the inputs use push buttons art. xx008-16080-30054-xx052-16083.
• If the device is not configured, P controls the relay output whereas IN1 and IN2 are not active.
• RGB LED that indicates the configuration status (flashing blue).
• Module 03983 can be associated with up to 2 flat controls (art. 03925) which make it possible
to control the actuator or activate one or more scenarios.
• The device works as a repeater node for battery-operated devices (for instance art. 03980).
• Operating temperature: -25 ÷ +55 °C.
• Protection degree: IP20
• Controllable via View App, Amazon Alexa, Google, Siri and Homekit voice assistantfor
Bluetooth technology system
OPERATION
The 03983 module is designed to:
- call up to 4 scenarios depending on the status of inputs IN1 and IN2.
- associate the flat control 30504-03925 which can be configured to control the actuator
on-board or to call up one or more scenarios.
- open an entrance configured as “Accesses”;
- perform Access Control functions via the View Key App (similarly to those of a landing reader
configured as “Accesses”);
- implement the room presence function by connecting IR or UWB radar sensors or magnetic
contacts with two wired inputs;
N.B. For the above functions please see the table entitled “CONNECTIONS TO MAKE PER
APPLICATION TYPE”.
Through the use of gateway 30807.x-20597-19597-16497-14597 the functions can be
managed via the View App, and the control is also available via the Amazon Alexa, Google
Assistant and Siri voice assistants.
The device is compatible with Homekit.
Settings.
The View Wireless App can be used to set the following parameters:
- Load status when the voltage is restored: off, on or previous status (default: previous status).
- Relay operation: two-position stable or one-position stable (default: two-position stable).
- One-position stable activation time (minimum activation time 1 s; default: 60 s).
- Control unit scenario activation delay.
REGULATORY COMPLIANCE.
RED Directive. RoHS directive.
Standards EN IEC 60669-2-1, EN IEC 63000, EN 301 489-17, EN 300 328, EN 62479.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries
and Regions. App Store is a service trademark of Apple Inc. Google is a trademark of Google LLC. Amazon, Alexa and
all related logos are trademarks of Amazon.com, Inc. or its afliates.
WEEE - User information
The crossed out bin symbol indicates that the product must be sent to separate collection facilities for recovery
and recycling, in compliance with the national laws of EU Countries that implement the WEEE Directive. The
objective is to prevent any harmful effects on the environment and on human health by ensuring that products
are disposed of correctly, avoiding illegal disposal sanctioned by law.
To dispose of the product correctly, please check local dispositions in your country.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03983 01 2410
CONNECTION FOR ACOUSTIC SIGNALLING AND ACTIVATION OF TWO SCENARIOS
FRONT VIEW
A: Configuration LED
N: Neutral
L: Phase
OUT: SELV NO/NC relay output
IN-: Common inputs
P, IN1, IN2: Programmable digital inputs
P1: Buzzer control push button (art. 30054-xx052-16083)
P2, P3: Scenario control push button (art. xx008-16080).
N L OUT
P
IN 1
IN 2
IN -
P
IN 1
IN 2
IN -
L
N
1
10mm
L1
10mm
L
+V
Vo
Adj.
−V
INPUT:( ):输入
OUTPUT:( ):輸出
100-240VAC
0,5A 50/60Hz
12V
NL
1,25A
10.8~13.8V
Max.1.25A
Max.15Watt
MEAN
WELL
“Terminal torque 4.4 Lb-in”
“Terminal torque 4.4 Lb-in”
N L OUT
P
IN 1
IN 2
IN -
1
10mm
L
2
BUZZER
A
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03983 01 2410
CONNECTION FOR SCENARIOS DEPENDENT UPON THE INPUTS
P1: Door release push button
A: Power supply unit
Third-party control unit with voltage-free contact outputs: scenario control
CONNECTION FOR LIGHT CONTROL
P1: Lamp control push button
P2, P3: Control push buttons for scenarios
L
N
1
10mm
L 1
10mm
L 1
10mm
L
+V
Vo
Adj.
−V
INPUT:( ) :输 入
OUTPUT :( ):輸出
100- 240VAC
0,5A 50/60Hz
12V
NL
1,25A
10.8~13 .8V
Max.1.25A
Max.15Watt
MEAN
WELL
“Termina l torqu e 4. 4 Lb-in ”
“Termina l torqu e 4. 4 Lb-in ”
N L OUT
P
IN 1
IN 2
IN -
COMBINATION EXAMPLES
IN1 IN2 Selected scenario
0 0 Scenario 1 (not used)
0 1 Scenario 2 (for instance “Entry”)
1 0 Scenario 3 (for instance “Exit”)
1 1 Scenario 4 (for instance “Relax”)
L
N
1
10mm
L
COM
OUT1
OUT2
N L OUT
P
IN 1
IN 2
IN -
+V V−
MEAN
N L
ELECTRICAL LOCK
THIRD-PARTY
CONTROL UNIT
0 = Open
1 = Closed


Product specificaties

Merk: Vimar
Categorie: Niet gecategoriseerd
Model: 03983

Heb je hulp nodig?

Als je hulp nodig hebt met Vimar 03983 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Vimar

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd