1User Manual
WALL-MOUNTED 4G-LTE SMART THERMOSTAT
Read all the instructions carefully
4DEVICE DESCRIPTION
DIMENSIONS
2130
85
28
3CONNECTION DIAGRAM
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
V3IS01188-010 Mod. TUO 4G
Wall-mounted 4G-LTE smart thermostat suitable for controlling heating and air conditioning
systems with weekly programming and mains power supply. The device can be managed
using the App, which is available for free for iOS and Android systems. Programming,
switching on the system, changing the operating settings and creating new program are all
operations that can be carried out easily and from anywhere thanks to the integrated 4G-LTE
module that connects the smart thermostat to the Internet. The SIM card supplied and installed
in the device, which includes 2 years of data traffic, can be extended using the application or
replaced. TUO 4G is an electronic device that perform actions of 1B type and are intended to
operate in environments with III overvoltage category and pollution degree 2 in accordance with
EN 60730-1 standard.
Code Model Description
VE795800 Tuo 4G Bianco Weekly smart thermostat with SIM card included, white
VE795900 Tuo 4G Nero Weekly smart thermostat with SIM card included, black
SAFETY WARNINGS
During the installation and the operation of the instrument it’s necessary to observe the
following instructions:
1) The instrument must be installed by a qualified person by observing scrupulously the
connection diagrams.
2) The instrument must be installed and activated in compliance with current electric systems
standards.
3) After installation, inaccessibility to the connection terminals without appropriate tools
must be granted.
4) Do not use the instrument for other purposes different from the one specified.
5) In the power supply network a bipolar disconnection must be present.
6) A protection device against over-currents should be installed in the electrical system,
upstream of the device.
7) Before accessing the connection terminals, verify that the leads are not live.
8) Do not power on or connect the instrument if any part of it is damaged.
TECHNICAL CHARACTERISTICS
Power supply: 230 Vac ±10% 50/60 Hz
Backup battery: rechargeable AAA NiMH type, capacity 950 mAh
use only NiMH rechargeable batteries
Output: bistable relay with changeover contact 5 A / 250 Vac
Weekly programming with 3 settable temperatures: T1, T2, T3
Daily Resolution: 1h
Switch-on delay settable between 15, 30 or 45 minutes (independent for each hour)
Measured temperature scale: 0°C ÷ 50°C
Measured and displayed temperature resolution: 0.1°C
Temperature regulation range: 2.0°C ÷ 50°C
Measurement accuracy: ± 0.5°C
Temperature regulation:
– on/off with adjustable differential between 0.1°C and 1°C
– proportional with settable band and regulation period
Operating mode: heating (winter) or conditioning (summer)
Configurable display backlight
Display of relative humidity (regulation is not allowed)
Automatic winter time/summer time
Keypad lock with password for installation in public places
Wall installation (or covering the box 503)
Terminal block for cables with section of 1.5 mm
2
Operating frequency band:
– GSM/GPRS/EDGE 900/1800 MHz – LTE-FDD B1/B3/B5/B7/B8/B20
Maximum power of transmitted radiofrequency: 33 dBm
Operating temperature: 0°C ÷ 50°C
Operating humidity: 20% ÷ 90% non condensing
Storage temperature: -20°C ÷ 65°C
Degree of protection: IP40
Insulation: reinforced between accessible parts (front) and all other terminals
Manuals
download
PDF
Clock
Day of the week
Off operation
Active load (conditioning mode)
Active load (heating mode)
Measured temperature
Running daily program divided into 24 histograms, one for each hour of the day. Each hour
is associated with one of the 3 temperatures:
Temperature T1 Temperature T2 Temperature T3
Active timed operation
Receiving a command
Vemer Cloud connection active
Measured relative humidity
Configuration menu
Local active operation. In this state the device is disconnected from the Cloud Vemer
and any change in operation must be made using the keys on the smart thermostat.
Local operation can be disabled by the app
Active keypad lock
5INSTALLATION
4
5
click
1 2 3
Open the door of the terminal compartment
Connect the load and the power supply (see connection diagram) and fix the device to the wall
Close the door of the terminal compartment
Insert the back-up battery into the special housing, ensuring the correct polarity, and place the
front part on the wall-mounted part, ensuring the correct connection of the two parts
Close the device by rotating the front panel downwards
7REMOTE CONTROL CONFIGURATION
To configure the device using a smartphone proceed as follows:
2. Choose and fill in the "e-mail" and "password" fields"REGISTER NOW"
Note: for security reasons, it is advisable to choose a password different from the one used to
access your e-mail inbox
3. Check your e-mail address: confirm account activation by clicking on the link contained in the
e-mail sent by the system
4. Log in by entering the e-mails and passwords chosen during registration
• Start the device configuration procedure on the App by carefully following the step-by-step
instructions in the wizard
Important: The following figures display the App at the time of publication of these user
instructions. Newer versions of the App may deviate in terms of graphics and content.
6 WARNINGS AND PRELIMINARY OPERATIONS FOR THE CORRECT
POSITIONING AND CONNECTION OF THE DEVICE
WARNINGS
The use of the smart thermostat through the Clima APP
requires a stable 4G-LTE network to ensure a good Internet connection.
Make sure you have a Vemer account.
The SIM card supplied and installed in the device
can be replaced by another with the same characteristics.
Removing the SIM cared supplied and installed in the device causes its
immediate and automatic deactivation, rendering it unusable.
• Install and connect the device in accordance with the installation instructions in this manual.
• The device can be installed on the wall or to cover the 3-module flush-mounting box (type 503).
It is advisable to install the device at a height of 1.5 metres from the floor, in an area that reflects the
average temperature conditions of the room as closely as possible.
Avoid installation near doors or windows, in nooks, behind doors and curtains or where there is
excessive or no ventilation.
• Ensure that the 4G-LTE signal is such as to ensure stable communication.
In the event that the device cannot reach the Vemer Cloud due to connectivity problems,
the LOCAL OPERATION allows complete management, programming and configuration of the
smart thermostat through its keypad. In this way, the device does not check for new settings
on the Cloud and adjusts the temperature according to the settings entered from the keypad
(the programming and configuration in the Cloud are not changed).
8BACKUP BATTERY
The device is equipped with a back-up battery, which makes it possible to send a message in the event
of a power failure (e.g. in the event of a blackout) and to maintain the time until the battery is completely
discharged. The battery is recharged by the unit and takes approximately 48 hours to be fully charged
when plugged in. The backup battery is accessible by removing the front of the device from the wall
socket and can be replaced without disconnecting the power supply.
Use NiMh batteries (type AAA) with a capacity of 950 mAh or higher.
Use only rechargeable batteries
RECHAR GEABL E
It is necessary to remove the batteries before the instrument is scrapped.
In case of replacement, dispose of the batteries in the appropriate
places separate waste collection containers.
9BATTERY DISPOSAL
To reset if the key lock is active and you do not know the unlock password, you must:
1. remove the front of the device from the partxed to the wall
2. remove the backup battery for at least 10 seconds (see BOX 8)
3. reposition the backup battery and when the display shows all the segments, press and hold
the key until " " appears.DEF
Operating mode heating
(winter)
Regulation type on/o
Dierential (on/o) 0.3°C
Band (proportional) 0.5°C
Period (proportional) 10 minutes
Antifreeze temperature OFF 6°C
Adj. ADJ temperature 0°C
Min. settable temperature 2°C
Max. settable temperature 50°C
Hour meter operation / 0 h
Automatic summer time change active
(according to EU rules)
Backlighting active
Key lock password deactivable
11 DEVICE RESET
Perform a reset to erase the entered settings and return the unit to the factory
settings.
To reset:
1. from the home screen, press and hold the key to access the configuration menu.
CLOCK indication starts flashing
2. keep the keys pressed at the same time and until " " appears on the display.RES
3. when the display shows all segments, press and hold the key until " " appears DEF
LOCAL OPERATION
(WHAT TO DO IF THERE IS NO CONNECTION)
SET
SET
+
Initial screen
Configuration
menu
3s 3s
3s
To switch from automatic to manual operation
To switch from manual to automatic operation
To switch from automatic operation (or manual) to the one switched off and vice versa
Manual
operation
Tm operation
Automatic
operation
Manual
operation
Automatic
operation
Tm operation
3s
Automatic
operation
Off
operation
3s
3s
Local operation is indicated by the icon on the App and device
display, and can be paused and/or disabled at any time from the
App (but not from the device).
If local operation is disabled (useful if you only want to control the
device from the App), the icon will appear on the display and
if you try to access the configuration menus from the device's
keypad, you will not be able to make any changes.
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efcient sorted waste collection for the environmentally friendly disposal of the used device
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
• Create a Vemer account:
1. Install and launch the Clima Vemer App on your smartphone (or tablet)
Tuo 4G
CLOCK MENU - DATE AND TIME SETTING
When connected to the Wi-Fi network, the device acquires the date and time settings from the
server and no settings are required.
However, if you need to manually set the date and time values, proceed as follows:
SET MENU - TEMPERATURES T1, T2, T3 SETTING
Access the SET menu to change the values of the 3 temperatures used in automatic operation. The
factory setting includes:
• T1 = 5 °C, T2 = 15 °C, T3 = 18 °C (heating/winter operation )
• T1 = off, T2 = 23 °C, T3 = 25 °C (conditioning /summer operation
How to change the temperature values T1/ T2/ T3
To exit the temperatures change:
• press the key once to return to the configuration menu
• press the key twice to exit the menu and return to the initial screen
Note: temperature values between L0 (minimum value) and kI (maximum value) are allowed.
These factory values are: L0 = 2°C, kI = 50°C but can be modified through the ADV menu.
Note: the condition T1 ≤ T2 T3 must be respected.
To exit the timing change:
• press the key once to return to the configuration menu
• press the key twice to exit the menu and return to the initial screen
When a timing is in progress, the symbol is lit.
Note: to cancel a timing in progress or to exit without activating the timer, set 00’.
Note: the timing ends in the case of changes to the operating mode.
To exit the date and time setting:
• press the key once to return to the configuration menu
• press the key twice to exit the menu and return to the initial screen
• to change the settings of the summer/winter time change, press and hold for a long time the
key (see “Configuration of the summer/winter time change”)
Configuration of the summer / winter time change
You can configure the device to independently manage the summer time update.
The factory setting includes:
• the passage winter time summer time (+1h) the last Sunday of March at 2:00 o’clock
• the passage summer time winter time (-1h) on the last Sunday of October at 3:00 o’clock
To change the configuration of the summer/winter time change:
• when changing any of the clock parameters (seconds, minutes, hour, year, month or day),
keep the key pressed for a long time until the display shows AUTO
PROG MENU - PROGRAM SETTING
Access the PROG menu to change the programming of the automatic operation.
The factory setting includes:
• the P1 program from Monday to Friday
• the P2 program on Saturday and Sunday
If this program is not suitable for your needs, you can:
• assign a different program for one or more days of the week
• modify one or more existing programs by personalizing the profile, that is, assigning different
temperature levels for one or more hours of the day.
How to choose a different program for the day Y
If the function is enabled (AUTO ON), for each time change it is necessary to set:
1 the day of the week(1= Monday...,7= Sunday)
2 the week of the month (1st= first, 2nd= second,...LSt= last)
3 the month
4 time
using the keys and to set the value and the key to confirm and move on to the next
parameter.
To exit the summer/winter time change configuration:
• press the key once to return to the configuration menu
• press the key twice to exit the menu
Note: the winter time change summer time is identified by the symbol .
the summer time change winter time is identified by the symbol .
For example, in Italy the summer time starts the last (LST) Sunday (7) of March (03)
at 2:00 o’ clock and the last (LST) Sunday (7) of October (10) at 3:00 o’ clock.
2
4
1
3
If the program meets the needs:
• press the key once to confirm and choose another day to which to assign
a different program
• press the key twice to return to the configuration menu
• press the key three times to exit the menu and return to the initial screen
If no program meets the needs:
• choose the one that is closest to your needs and press the key to customize
the profile (see “How to customize the profile of a Px program”)
How the switching delay works
Set a switching delay for a specific hour to maintain, for the duration of the delay, the
temperature value assigned to the previous hour.
For example, if the program includes:
T2 from 12 to 13 and T3 from 13 to 14 pm with 30 minutes delay
the smart thermostat adjusts the temperature based on the value of
T2 from 12 to 13.30 and T3 from 13.30 to 14.00
It is possible to set delays of 15, 30, 45 minutes, independent for every hour of the day.
12 CONFIGURATION AND PROGRAMMING
Parameters for the regulation type
(this menu varies depending on the chosen regulation type)
If the type of adjustment chosen is on/off, set the differential .diff
Allowed values: 0.1 °C ÷ 1 °C Factory value: 0.3°C
If the type of adjustment chosen is proportional, set the band and the bnd
period per.
Allowed values: 0.5 °C ÷ 5 °C (band), 10, 20 or 30 minutes (period).
Factory value: 0.5 °C (band), 10 minutes (period).
Adjustment of the measured temperature
Under certain installation conditions, the temperature measured by the unit may
differ from the average room temperature. In this case, enter a temperature
adjustment using the ADJ menu.
Allowed values: -5°C ÷ 5°C
Factory value: 0 °C.
Note: the temperature value displayed on the display during normal
operation includes any adjustment made.
Antifreeze temperature
(this menu is active only if operating mode = heating)
The anti-freeze temperature prevents the system from freezing up when the
operation is set to "Off" on the smart thermostat .
Allowed values: --- , 1 °C ÷ 50 °C
Factory value: 6 °C.
Note: the " " setting disables the antifreeze function; in this case, when ---
the device is switched off, no minimum temperature is guaranteed.
Password for key lock
In particular installation conditions, for example in public buildings, hotels, etc., it may be
necessary to lock the keypad in order to prevent unauthorized persons from changing the
settings.
Hour meter of system operation
Displays the hours of operation of the system(relay contacts on C-NA).
The unit has two independent (5-digit) meters for heating and air
conditioning, but only the meter for the selected mode is displayed. To reset
the meter, press and hold the key for a long time during the display. The
maximum count is 65535h (about 7 years); when this number is reached, the
meter resumes counting from 0h.
4G-LTE and De-Link connection configuration
This menu displays the following information:
- the presence of the 4G-LTE signal (1)
- the level of the 4G-LTE signal (2) on the total available (3)
From this menu it is also possible to:
turn on/off the 4G-LTE module (useful, for example, if a properly functioning
SIM card is not available). Switching off the module means that the device can
only be managed from the keypad in Local Operation (see BOX 10). To turn the
module on/off, press the key for at least 3 seconds until (power off) or 0ff 0n
flashing (power on) appears.
remove the device from the control of one user (DE-LINK) in order to reconfigure
it with another (typical situation, for example, when the device is installed in a
rented property and the tenants change).
To carry out the De-Link, press and hold the keys and until the display
shows " ", after restarting the device the display shows "RES dEL".
The De-Link procedure is finished; at this point the icon on the smart
thermostat display starts flashing.
REFERENCE STANDARDS
10-2024
EU Declaration of Conformity:
Vemer declares that the device complies with EU Directive 2014/53/EU (RED)
with reference to the following standards:
• EN 60730-2-7 • EN 60730-2-9 • ETSI EN 300 511 • ETSI EN 301 489-1 • ETSI EN 301 489-52
The full text of the EU Declaration of Conformity is available at the Internet address
www.vemer.it
13OTHER FUNCTIONS OF THE DEVICE
Display of minimum/maximum daily temperature and humidity
The device stores the minimum and maximum temperature and humidity values measured during
the day 3s
3s
Initial screen
Maximum values
display
Maximum values
resetting
Initial screen
Minimum values
display
Minimum values
resetting
Keypad unlock
When the key lock is active, the device adjusts the temperature using the set programming. In this
condition, after pressing a key, the display shows the word " "BL0C
To unlock the keypad:
1. When the word " is displayed, press and hold any of the four keys until the display BL0C
shows " ".---
2. Enter the correct password with the keys and and confirm with the key .
The keypad remains unlocked for approximately 45 seconds after the last key is pressed,
after which the keypad reactivates the lock.
(To remove the key lock, see BOX 12)
Set the seconds Set the minutes Set the time
Set the year Set the month Set the day
Configuration menu
SET
3s
Initial screen
x1 time
Initial screen Configuration menu PROG. Menu
SET
SET
3s
Choose the day Y
Choose
the Px program
How to customise the profile of a Px program
starting from midnight 00:00, press the keys and to assign to each hour of the day one of the
3 possible temperatures (T1, T2, T3) and the key to confirm and go to the next hour.
to enter a switching delay for the selected hour, hold down the key for a long time.
For more information about switching delay, see “How the switching delay works”
When the profile program is suitable for your needs:
• press the key to exit the customization.
Choose the
PX program
Choose the temperature
for the selected time
Choose the temperature
for the next hour
SET
3s
Initial screen Configuration menu
x2 times
SET Menu
Change T1 Change T2 Change T3
SET
3s
Set the timing. Increments of:
- 15 minutes (’) for timings up to 24 hours
- 1 hour (h) for timings from 1 to 5 days (d)
- 12 hours for timings from 5 to 99 days
Initial screen Menu configuration TIMER menu
x3 times
Type of regulation
(this menu is active only if operating mode = heating)
Set:
O to choose the on/off adjustment.
P to choose the proportional adjustment.
Factory value: (on/off).O
Note: the on/off adjustment is suitable for most household situations. It is
therefore advisable not to change this parameter unless absolutely necessary.
ADV MENU - ADVANCED PARAMETERS SETTING
Configuration menu ADV menu
x4 times
SET
3s
Initial screen
In the ADV menu, the parameters related to the advanced configuration of the device are proposed in
sequence. Press:
• the keys and to change the value of the selected parameter
• the key to go to the next parameter
• the key to exit and confirm the changes
Note: the device exits the menu after about 40 seconds without any key being pressed.
Operating mode
Setting up:
RISC if the device is connected to a heating system
(winter operation)
COND if the device is connected to an air conditioning system
(summer operation)
Factory value: (heating).RISC
Minimum/Maximum settable temperature
In certain installation conditions, e.g. public buildings, hotels, etc., it may be
useful to limit the range of values that the T1/T2/T3 and Tm temperatures can
take, in order to prevent incorrect settings by the user.
is the lower limitL0
Allowed values: 2 °C ÷ ki
Factory value:C
is the upper limitki
Allowed values: ÷ 50 °C L0
Factory value: 50°C
Display backlighting
The display backlight can be:
(blue after pressing a key)OFF
• fixed colour, which can be chosen from 48 variants
• variable ( ) based on the difference between the measured and set temperature:RGB
- blue when the measured temperature is lower than the set temperature by at least 0.5 °C
(and after pressing a key)
- green when the difference between the measured temperature and the set temperature is
less than 0.5°C in absolute value (and in off mode)
- red when the measured temperature is higher than the set temperature by at least 0.5 °C
colour 1 ..... colour 48 Off RGB
The backlight can also be activated/deactivated from the home screen, by pressing and holding the
key for a long time .
Hourly timing of the backlight
(this menu is active only if the display backlight is not turned off - 0ff)
In certain installation conditions, such as bedrooms, it may be useful to limit
the display backlighting to daytime only.
You can choose the display backlighting daily start time 0n
and end time 0ff.
Allowed values for start time ( ): --:-- (always on), or from 00:00 to 23:450n
Allowed values for end time ( ): from 00:00 to 23:450ff
Factory value: --:-- (backlight always on)
Backup battery operating status
Indicates the presence and operating status of the backup battery.
indicates that the battery is working properly 0K
indicates that the battery is not present or needs to be replaced ERR
TIMER MENU - TIMING SETTING
Set a timing to prolong the current operation for the duration of the timing itself. There are 3
timings available:
• Timed manual: set a timing during manual operation to maintain this operation until timing
has elapsed. At the end of the timing, the device activates the automatic operation.
• Timed automatic: set a timing during the automatic operation to maintain this operation
until the timing has elapsed. At the end of the timing, the device activates the off operation
• Off timed: set a timing during off operation to maintain this operation until timing has elapsed.
At the end of the timing, the device activates automatic or manual operation, depending on
which operation was active before switching off.
How to set a timing
To enable keypad locking, set a password between 001 and 999.
To deactivate the lock, press and hold the key until "--" is set.
When the keypad lock is active, the symbol appears on the display
and after pressing a key the word BL0C appears.
(To find out how to unlock the keypad, see BOX 13)