ETW193 electronic programmable timer
OWNER’S
MANUAL
Congratulations on your
purchase of a UPM timer.
Please take the time to
read and understand this
manual so you can begin
to enjoy the security and
energy saving benefits this
product has to offer.
FEATURES
!
!
!
!
!
!
20 ON programs /
20 OFF programs
3 random functions
12/24 hour clock
500W loading
single pole or three-way
Countdown timer -
“One-Touch Countdown”
SINGLE POLE INSTALLATION
1
2
Remove existing switch and identify the wires in the wall box.
Using the supplied wire nuts, securely fasten the wires on the timer
to the wires in the wall box according to diagram FIGURE 1.
3
Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
Connect one of the (hot) wire on the timer to the
wire in the wall box.
black hot
Connect the other (hot) wire on the timer to the wire
in the wall box coming from the light fixture.
black hot
GETTING STARTED setting the clock
1
4
2
1
5
6
7
8
Press SET
Day select with
Press SET
Hour select with
Press SET
Minute select with
3
5 7 9
2
4
6
8
10
9
10
3
Press SET
Second select with
Press SET
Press SET
Minute select with
memory backup
This UPM wall switch timer comes with built-in memory backup protection. In the
event of a power outage, all program and clock settings will remain in memory.
CLO CK ON
MO
CL OCK O N
MO
To activate/deactivate Daylight Saving Time (DST) function, press and hold
both and together for 3 seconds in mode; solid for DST
CLOCK
To toggle between 12/24 hour format, press RND during clock setting
CAUTION!
*
This timer is only compatible with incandescent (120V) lighting
applications. The timer must be used with magnetic
transformers, motors or loads exceeding 500W.
NOT
All wiring must comply with applicable codes and regulations.
TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT
THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS
OFF BEFORE WIRING.
Handle installation with caution to prevent any risk of electrical shock
that could cause serious injury or death. If you are not sure about any
part of the given instructions, consult a qualified electrician.
For proper grounding, connect the (ground) wire on
the timer to the ground “screw” found inside the wall box.
green
Mount timer into the wall box carefully.
Restore power supply at the circuit breaker or fuse.
4
5
Terminate the (three-way) wire on the timer with a wire nut.
(For a single pole installation, the red wire is not needed).
red
INSTALLING THE TIMER IN PLACE OF LOAD SWITCH
FIGURE 3
THREE-WAY INSTALLATION DIAGRAM
JUMPER WIRE
COMMON TERMINAL
HOT WIRE
HOT WIRE
CLOSE UP VIEW OF THE HOT SWITCH
Go to using
CLOCK
GETTING STARTED button placements
display
1
2
CD - activates countdown timer
3
4
SET - activates set functions
RND - activates random functions
5
- scrolls through selections
6
ON/OFF - manual on/off control
7
Main On/Main Off
R - reset
1
4
2
5
6
7
3
CLOCK CDSETRNDL
-PROG ONOFF
MO TU WE TH FR SA SU
X
Set function indicator
Weekday indicators
Random function indicator
AM/PM
Clock function
indicator
Disabled program
icon
ON/OFF indicator
8
8
One-Touch Countdown Button
One-Touch
Countdown
Countdown function indicator
Power Source
Red
ETW193
JUMPER 3 Way
Black
Black LOAD
COMMON Green
HOT SWITCH
PAGE 1 PAGE 2 PAGE 3
PAGE 10 PAGE 11 PAGE 12
hp://waterheatermer.org/UPM-mers -and-manuals.html
SINGLE POLE INSTALLATION DIAGRAM
FIGURE 1
PROG ON
MO TU WE T H FR SA SU
1
3
5 7
2 4 6 8
PROGON
MO T U WE TH FR S A S U
4
3
2
1
X
THREE-WAY INSTALLATION
1
2Remove existing switch and identify the wires in the wall box.
Using the supplied wire nuts, securely fasten the wires on the timer
to the wires in the wall box according to diagram FIGURE 2.
3
Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
Connect one of the (hot) wire on the timer to the
wire in the wall box.
black hot
Connect the other (hot) wire on the timer to the
wire in the wall box coming from the LOAD switch.
black load
Connect the (three-way) wire on the timer to the
wire in the wall box coming from the LOAD switch.
red three-way
Mount timer into the wall box carefully.
Restore power supply at the circuit breaker or fuse.
4
8
THREE-WAY INSTALLATION
There are two switches in a three-way circuit. The switch directly
connected to the circuit breaker is the HOT switch. The second switch is
the LOAD switch. Ensure you know which switch you are replacing.
INSTALLING THE TIMER IN PLACE OF HOT SWITCH
For proper grounding, connect the (ground) wire on
the timer to the ground “screw” found inside the wall box.
green
ADDING A JUMPER WIRE TO THE LOAD SWITCH
*Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
5Take out the LOAD switch and identify the terminal.common
6Connect the wire to the LOAD switch according to diagram
FIGURE 2.
jumper
Connect the wire from the terminal to the
terminal of the LOAD switch.
jumper common
hot
Mount LOAD switch back into the wall box carefully.
7
Load Switch
Power Source 3-Way
Timer
Select program 20 with
Flashing for short random
Flashing for long random
RANDOM FUNCTION
3
2
1
short/ randomlong
programmable random
4
1
2Press RND
Set program 20 to desired random time
3
4
1
2Press RND
3
Short random from
OR Long random from
CLOCK
CD
RND
LRND
-
Solid for programmable random
RND
* Short random 1-2 hours, long random 2-3 hours
* Programmable random only works with program 20; 1-2 hours
3
2
1
Deactivate random function with RND or ON/OFF
COUNTDOWN TIMER
1
4
2
5
6
7
8
Press SET
Start ON or OFF select with
Press SET
Hour select with
Press SET
Minute select with
9
10
3
Press SET
Second select with
Press SET
The to-the-second countdown feature of this timer starts from the ON or OFF
position and counts down to zero when activated.
CD P ROGON
3
5 7 9
1
2
4
6
8
10
CD P R O GON
Stop countdown timer with CD or ON/OFF.(or )One-Touch Countdown Button
Select CD mode using
Press CD or the to start the countdown timer.One-Touch Countdown Button
PROGRAM SETTINGS
disable program/master disable
1
4
2
5
7
8
*
*
Press SET
Day select with
* Individual days / weekly selections
Press SET
Hour select with
Press SET
Minute select with
3
Press SET
Each program has an “ON” and “OFF” setting. Both must be set for operation.
Example: PROG 1 has an “ON” and “OFF”
Program select with
1
2
Press SET
Press ON/OFF to disable ( )X
3
For select PROGRAM with
or go to using
single disable
F master disable
Press SET 3 times to exit (single disable)
OR press SET 4 times to exit (master)
CLOCK
Programs are arranged in a circular pattern
with the clock and countdown functions:
CLOCK
Program 1–20
CD
4
Repeat steps to to undo disable )( X
14
For a single program disable, both the “ON” and “OFF” setting must be disabled
individually
6
ETW193
Black
Black
Green
LOAD
Power Source
Black
Screw
Red
PAGE 4 PAGE 5 PAGE 6
PAGE 13 PAGE 14 PAGE 15
Hot Switch
Power Source 3-Way
Timer
Restore power supply at the circuit breaker or fuse.
8
THREE-WAY INSTALLATION
ADDING A JUMPER WIRE TO THE HOT SWITCH
*Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
5Take out the HOT switch and identify the terminal.common
6Connect the wire to the HOT switch according to diagram
FIGURE 3.
jumper
Connect the wire from the terminal to the
terminal of the HOT switch.
jumper common
hot
Mount HOT switch back into the wall box carefully.
7
TROUBLESHOOTING
LCD display seems “frozen”.
Buttons won’t respond.
Programmed ON/OFF times
don’t execute.
Programmed ON/OFF times
don’t execute at specified times.
Three-way switch is not working
properly.
Press reset button to reset timer.
Ensure that the program disable
feature is not enabled.
Ensure that the random function
is not enabled.
Disconnect power supply at the
circuit breaker or fuse. Check
installation for proper wiring.
problem solution
TECHNICAL SPECIFICATIONS
Program: 20 programs
Ratings: 120V AC
Max Load: 500W; single pole or three-way
Min switching time: 1 minute
INSTALLING THE TIMER IN PLACE OF HOT SWITCH
THREE-WAY INSTALLATION DIAGRAM THREE-WAY INSTALLATION
1
2Remove existing switch and identify the wires in the wall box.
Using the supplied wire nuts, securely fasten the wires on the timer
to the wires in the wall box according to diagram FIGURE 3.
3
Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
Connect one of the (hot) wire on the timer to the
wire in the wall box coming from the lighting fixture.
black hot
Connect the other (hot) wire on the timer to the wire
in the wall box coming from the HOT switch.
black hot
Connect the (three-way) wire on the timer to the
wire in the wall box coming from the HOT switch.
red three-way
Mount timer into the wall box carefully.
4
INSTALLING THE TIMER IN PLACE OF LOAD SWITCH
For proper grounding, connect the (ground) wire on
the timer to the ground “screw” found inside the wall box.
green
JUMPER WIRE
COMMON TERMINAL
HOT WIRE
HOT WIRE
FIGURE 2
CLOSE UP VIEW OF THE LOAD SWITCH
Red
ETW193
JUMPER
3 Way
Black
Black
Power Source
LOAD
COMMON
Green
LOAD SWITCH
PAGE 7 PAGE 8 PAGE 9
PAGE 16


Product specificaties

Merk: UPM
Categorie: Schakelaar
Model: ETW193

Heb je hulp nodig?

Als je hulp nodig hebt met UPM ETW193 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Schakelaar UPM

Handleiding Schakelaar

Nieuwste handleidingen voor Schakelaar