Tripp Lite SUPDMB568HW Handleiding
Tripp Lite
Stekkerdoos
SUPDMB568HW
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SUPDMB568HW (8 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/8
Owner’s Manual
Manual del propietario / Manuel du propriétaire
Series Number / Número de serie / Numéro de série :
AGAC5553 (SUPDMB710), AGAC5591 (SUPDMB710HW), AGPD7040 (SUPDMB710IEC)
Español 4 • Français 6
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
Copyright © 2018 Tripp Lite. Todos los derechos reservados. / © 2018 Tripp Lite. Tous droits réservés.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
Detachable Power Distribution Modules
SUPDM Series
For use with SmartOnline
® Rack/Tower UPS Systems requiring a detachable PDM.
Módulos de distribución de potencia desmontables
Serie SUPDM
Para uso con UPS SmartOnline
® de montaje en bastidor/torre que requiera un PDM desmontable.
Modules de distribution d’alimentation détachables
Série SUPDM
Pour utilisation avec les systèmes UPS SmartOnline
® en bâti ou en tour, exigeant un PDM (module de distribution d’alimentation) détachable.
2
Important Safety Warnings! SAVE THESE INSTRUCTIONS.
Connecting the SUPDM to the UPS Power Module
1 If the the Power Module contacts A and/or SUPDM contacts B are protected by a box or cover, unscrew and remove it to expose the contacts. Consult your
UPS Owner’s Manual for the exact location of the contacts on your Power Module and SUPDM.
2 Align the SUPDM and Power Module contacts C.
3 Secure the SUPDM to the Power Module with screws D (included). Consult your UPS Owner’s Manual for detailed installation instructions.
4 Connect the SUPDM to utility power, either by plugging it into an AC wall outlet or by hardwiring it to an appropriate AC power source, as applicable.
5 Connect your equipment to the UPS either by plugging it in or hardwiring it to the SUPDM.
CAUTION: Hardwiring should only be performed by a qualified electrician.
Consult your UPS Owner’s Manual for specific connection/hardwiring instructions, or call Tripp Lite for assistance at 773.869.1234.
This manual contains important instructions and warnings that should
be followed during the installation and operation of all SUPDM Power
Distribution Modules. Use this manual in conjunction with the owner’s
manual for your SmartOnline Rackmount/Tower UPS System. Follow all safety
warnings, including the following:
• SUPDM connection must be performed by qualified service personnel.
• The UPS system must be powered down and completely disconnected
from utility power, external battery module(s) and connected equipment
prior to connecting the SUPDM.
• There are no user serviceable parts. Do not modify or drill holes into
enclosure. Installation, maintenance is by Qualified Service personnel
only.
• This unit is intended for installation in a temperature-regulated, indoor
area that is relatively free of conductive contaminants.
• Use of this equipment in life support applications where failure of this
equipment can reasonably be expected to cause the failure of the life
support equipment or to significantly affect its safety or effectiveness is
not recommended. Do not use this equipment within oxygen-enriched
atmospheres, or within 0.3 m (1 ft.) of a point at which an oxygen-
enriched atmosphere is intentionally vented.
AC Mains Installation
• Install in accordance with National Electrical Code standards.
• Be sure to use the proper wire size: 6AWG / 6 mm2 rated a minimum of
60C and overcurrent protection for the installation, in accordance with the
plug/equipment rating.
• Over-current protection shall be provided in the end use application,
installed in accordance with local and national electrical wiring regulations.
• In the US/Canada, the plug rating is required to be 125% of the
equipment current rating. Note if the equipment is rated 50A, then 50 x
125% = 62.5A plug is required.
• CAUTION: To reduce the risk of fire, connect only to a circuit provided
with a 50A branch circuit overcurrent protection in accordance with the
National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code,
Part I, C22.1.
• Short circuit back-up protection to be provided by building installation
• Be sure to provide a local disconnect device on any models that are
permanently installed without a plug that is easily accessible.
• For pluggable equipment the mains socket outlet that supplies the
equipment shall be installed near the equipment and shall be easily
accessible.
• Be sure to use conduit for permanently installed wiring to meet National/
local codes as required.
• The total load connected to the PDU must not exceed the maximum load
rating for the PDU.
• Use a properly sized Gland Fitting for flexible cables to provide strain relief.
• Use conduit/gland fittings for permanent connections, according to local/
national regulations.
High Voltage Warnings
Contacts on Power/Battery Module
(your model may differ)
Contacts on Detachable PDM
(your model may differ)
WARNING! High Voltage!
Risk of electrical shock!
Due to the presence of high voltage batteries, even without AC
present, these contacts A are live! Do not let these contacts
touch any surface!
WARNING! High Voltage!
Risk of electrical shock!
If AC is present and Bypass Switch is set to “Bypass”, these
contacts B are live! Do not let these contacts touch any surface!
A
A
SUPDMB56
SUPDM56HW
SUPDMB568HW
SUPDMB710
SUPDM710HW
SUPDMB710HW
SUPDMB710IEC
B
B
3
12 3 4 5
A
B
C
D
SUPDM56HW
SUPDMB568HW
SUPDMB710
SUPDMB710IEC
SUPDM710HW
SUPDMB710HW
SUPDMB56
12 3 4 5
D
A
B
C
12 3 4 5
B
C
D
12 3 4 5
A
C
D
B
12 3 4 5
A
C
D
B
12 3 4 5
D
A
C
12 3 4 5
A
B
C
D
B
A
Product specificaties
Merk: | Tripp Lite |
Categorie: | Stekkerdoos |
Model: | SUPDMB568HW |
Kleur van het product: | Zwart |
Gewicht: | 3990 g |
Breedte: | 444.5 mm |
Diepte: | 171.4 mm |
Hoogte: | 152.4 mm |
Gewicht verpakking: | 3990 g |
Breedte verpakking: | 238.8 mm |
Diepte verpakking: | 495.3 mm |
Hoogte verpakking: | 226.1 mm |
Materiaal behuizing: | Staal |
Land van herkomst: | China |
Afmetingen verpakking (BxDxH): | 521 x 248 x 241 mm |
Duurzaamheidscertificaten: | RoHS |
Afmetingen (B x D x H): | 444.5 x 171 x 152.4 mm |
(Buitenste) hoofdverpakking hoogte: | 226.1 mm |
(Buitenste) hoofdverpakking breedte: | 238.8 mm |
(Buitenste) hoofdverpakking brutogewicht: | 3990 g |
(Buitenste) hoofdverpakking lengte: | 495.3 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
AC-ingangsfrequentie: | 50 - 60 Hz |
Aantal AC uitgangen: | 1 AC-uitgang(en) |
Nominale input voltage: | 100-140 V |
Stopcontacttypes: | Eindstation |
Stroom (max.): | - A |
PDU types: | Modulair |
Netspanning, in bedrijf: | 120 - 240 V |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SUPDMB568HW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stekkerdoos Tripp Lite
30 Mei 2023
29 Mei 2023
26 Mei 2023
25 Mei 2023
23 Mei 2023
21 Mei 2023
18 Mei 2023
4 Mei 2023
4 Mei 2023
3 Mei 2023
Handleiding Stekkerdoos
- Stekkerdoos Apc
- Stekkerdoos Bachmann
- Stekkerdoos Brennenstuhl
- Stekkerdoos Digitus
- Stekkerdoos Eaton
- Stekkerdoos Eglo
- Stekkerdoos Eminent
- Stekkerdoos Ewent
- Stekkerdoos Furman
- Stekkerdoos Gembird
- Stekkerdoos Hama
- Stekkerdoos HQ
- Stekkerdoos Icy Box
- Stekkerdoos Konig
- Stekkerdoos Kopp
- Stekkerdoos Nedis
- Stekkerdoos Ufesa
- Stekkerdoos Oregon Scientific
- Stekkerdoos Caliber
- Stekkerdoos GoGEN
- Stekkerdoos Steren
- Stekkerdoos Ubiquiti Networks
- Stekkerdoos Sven
- Stekkerdoos REV
- Stekkerdoos Bauhn
- Stekkerdoos Kondator
- Stekkerdoos Intellinet
- Stekkerdoos Energenie
- Stekkerdoos CyberPower
- Stekkerdoos Yato
- Stekkerdoos DataVideo
- Stekkerdoos Kindermann
- Stekkerdoos ATen
- Stekkerdoos Lanberg
- Stekkerdoos Anton/Bauer
- Stekkerdoos StarTech.com
- Stekkerdoos Legrand
- Stekkerdoos Panduit
- Stekkerdoos EVOline
- Stekkerdoos V7
- Stekkerdoos Oehlbach
- Stekkerdoos Geist
- Stekkerdoos Salicru
- Stekkerdoos Adam Hall
- Stekkerdoos Panamax
- Stekkerdoos Altronix
- Stekkerdoos Middle Atlantic
- Stekkerdoos Tecnoware
Nieuwste handleidingen voor Stekkerdoos
14 November 2024
15 Oktober 2024
15 Oktober 2024
1 Oktober 2024
6 September 2024
6 September 2024
10 Juli 2024
18 Juni 2024
26 Maart 2024
19 Maart 2024