Tripp Lite PDUMH16HV Handleiding
Tripp Lite
Stekkerdoos
PDUMH16HV
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDUMH16HV (36 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/36
Owner’s Manual
Metered Rack PDU
Model: PDUMH16HV
(Series Number: AG-00D9)
Important Safety Instructions 2
Installation 3
Features 5
Warranty & Product Registration 7
Español 8
Français 15
Русский 22
Deutsch 29
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
18-11-319-93331C.indb 1 2/20/2019 4:44:40 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions may affect your
warranty.
Important Warnings
• Operate the PDU at indoor temperatures between 32°F and 104°F (between 0°C and 40°C)
only.
• Provide adequate protection against excess currents, short circuits, and ground faults in
accordance with local and national electrical code, such as NEC in the U.S.
• The mains socket that supplies the PDU should be near the PDU and easily accessible.
• The PDU provides convenient multiple outlets but it DOES NOT provide surge or line noise
protection for connected equipment.
• The PDU is designed for indoor use only in a controlled environment away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• Do not connect the PDU to an ungrounded outlet or extension cords or adapters that
eliminate the connection to ground.
• The power requirement for each piece of equipment connected to the PDU must not exceed
the individual outlet's load rating.
• The total power requirement for equipment connected to the PDU must not exceed the
maximum load rating for the PDU.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
• Do not attempt to modify the PDU, including the input plugs and power cables.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Never attempt to install electrical equipment during a thunderstorm.
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• The PDU must be installed by a qualified technician only.
• Install in accordance with local electrical codes. Be sure to use the proper over current
protection for the installation, in accordance with the plug rating/equipment rating.
• The electrical sockets supplying power to the equipment shall be installed near the equipment
and be easily accessible.
18-11-319-93331C.indb 2 2/20/2019 4:44:40 PM
3
Installation
Note: Regardless of installation configuration, the user must determine the fitness of hardware
and procedures before mounting. The PDU and included hardware are designed for common
rack and rack enclosure types and may not be appropriate for all applications. Exact mounting
configurations may vary.
1-1 1U Rack Installation. Attach the PDU to
the rack by inserting four user-supplied
screws A through the PDU mounting
brackets B and into the mounting holes of
the rack rail as shown.
1-2 0U Rack Installation. Part 1: Remove the
screws C attaching the mounting brackets
to the PDU, change the orientation of the
brackets as shown and reattach the
brackets. Use only the screws supplied by
the manufacturer or their exact equivalent
(#6-32, 1/4” flat head). Attach the Part 2:
PDU vertically by inserting two or more user-
supplied screws A through the PDU
mounting brackets B and into mounting
points in the rack or rack enclosure.
1-3 Wall Installation. After repeating Part 1
above, attach the PDU to a stable mounting
surface by inserting two or more user-
supplied screws A through the PDU
mounting brackets B and into secure
mounting points on the mounting surface.
1-4 Under-Counter Installation. After repeating
Part 1 above, attach the PDU to a stable
mounting surface by inserting four user-
supplied screws A through the PDU
mounting brackets B and into secure
mounting points on the mounting surface.
1-1
1-4
1-2
1-3
A
A
B
B
A
A
B
B
C
C
C
18-11-319-93331C.indb 3 2/20/2019 4:44:41 PM
Product specificaties
Merk: | Tripp Lite |
Categorie: | Stekkerdoos |
Model: | PDUMH16HV |
Kleur van het product: | Zwart |
Gewicht: | 1770 g |
Breedte: | 444.5 mm |
Diepte: | 165.1 mm |
Hoogte: | 44.4 mm |
Snoerlengte: | 2.5 m |
Gewicht verpakking: | 2950 g |
Breedte verpakking: | 519.9 mm |
Diepte verpakking: | 277.9 mm |
Hoogte verpakking: | 77 mm |
Materiaal behuizing: | Metaal |
LED-indicatoren: | Ja |
Beeldscherm: | LCD |
Land van herkomst: | Taiwan |
Afmetingen verpakking (BxDxH): | 521 x 279 x 76 mm |
Certificering: | CE (IEC / EN60950-1), GOST |
Duurzaamheidscertificaten: | RoHS |
Hoogte, in bedrijf: | 0 - 3000 m |
Afmetingen (B x D x H): | 444 x 165 x 28.7 mm |
Montage: | Horizontaal |
Stekker: | IEC309 |
(Buitenste) hoofdverpakking hoogte: | 77 mm |
(Buitenste) hoofdverpakking breedte: | 519.9 mm |
(Buitenste) hoofdverpakking brutogewicht: | 2950 g |
(Buitenste) hoofdverpakking lengte: | 277.9 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
Rackcapaciteit: | 1U |
Bedrijfstemperatuur (T-T): | -15 - 50 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Aantal AC uitgangen: | 10 AC-uitgang(en) |
Nominale input voltage: | 200-240 V |
Stopcontacttypes: | C13 coupler, C19 coupler |
Stroom (max.): | 16 A |
PDU types: | Gemeten |
Netspanning, in bedrijf: | 200-240 V |
Output-aansluitingen: | 8 x C13 & 2 x C19 |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite PDUMH16HV stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stekkerdoos Tripp Lite
30 Mei 2023
29 Mei 2023
26 Mei 2023
25 Mei 2023
23 Mei 2023
21 Mei 2023
18 Mei 2023
4 Mei 2023
4 Mei 2023
3 Mei 2023
Handleiding Stekkerdoos
- Stekkerdoos Apc
- Stekkerdoos Bachmann
- Stekkerdoos Brennenstuhl
- Stekkerdoos Digitus
- Stekkerdoos Eaton
- Stekkerdoos Eglo
- Stekkerdoos Eminent
- Stekkerdoos Ewent
- Stekkerdoos Furman
- Stekkerdoos Gembird
- Stekkerdoos Hama
- Stekkerdoos HQ
- Stekkerdoos Icy Box
- Stekkerdoos Konig
- Stekkerdoos Kopp
- Stekkerdoos Nedis
- Stekkerdoos Ufesa
- Stekkerdoos Oregon Scientific
- Stekkerdoos Caliber
- Stekkerdoos GoGEN
- Stekkerdoos Steren
- Stekkerdoos Ubiquiti Networks
- Stekkerdoos Sven
- Stekkerdoos REV
- Stekkerdoos Bauhn
- Stekkerdoos Kondator
- Stekkerdoos Intellinet
- Stekkerdoos Energenie
- Stekkerdoos CyberPower
- Stekkerdoos Yato
- Stekkerdoos DataVideo
- Stekkerdoos Kindermann
- Stekkerdoos ATen
- Stekkerdoos Lanberg
- Stekkerdoos Anton/Bauer
- Stekkerdoos StarTech.com
- Stekkerdoos Legrand
- Stekkerdoos Panduit
- Stekkerdoos EVOline
- Stekkerdoos V7
- Stekkerdoos Oehlbach
- Stekkerdoos Geist
- Stekkerdoos Salicru
- Stekkerdoos Adam Hall
- Stekkerdoos Panamax
- Stekkerdoos Altronix
- Stekkerdoos Middle Atlantic
- Stekkerdoos Tecnoware
Nieuwste handleidingen voor Stekkerdoos
14 November 2024
15 Oktober 2024
15 Oktober 2024
1 Oktober 2024
6 September 2024
6 September 2024
10 Juli 2024
18 Juni 2024
26 Maart 2024
19 Maart 2024