Tripp Lite PDU3EVN6L2120 Handleiding
Tripp Lite
Stekkerdoos
PDU3EVN6L2120
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDU3EVN6L2120 (68 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 56 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/68
1
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
3-Phase Monitored & Switched
0U Power Distribution Units
(Phase, Bank, Outlet Measurements*)
208V MONITORED
MODELS SERIES NO.
PDU3EVN3L2130 AG-00B9
PDU3EVN10L2130 AG-00B9
PDU3EVN3L2120 AG-00B8
PDU3EVN6L2120 AG-00B8
PDU3EVN10L2120 AG-00B8
PDU3EVN6L2130 AG-00B9
208V SWITCHED
MODELS SERIES NO.
PDU3EVSR6G60A AG-0094
PDU3EVSR6H50A AG-0094
200 – 240V
MONITORED
MODELS SERIES NO.
PDU3EVN6G30B AG-00BA
PDU3EVN10G30B AG-00BA
PDU3EVN3G60B AG-00BA
PDU3EVN6G60B AG-00BA
PDU3EVN10G60B AG-00BA
PDU3EVN3H50B AG-00BA
PDU3EVN6H50B AG-00BA
PDU3EVN6H50BA AG-00BA
PDU3EVN10H50B AG-00BA
PDU3EVN3L1520 AG-00BA
PDU3EVN6L1520 AG-00BA
PDU3EVN10L1520 AG-00BA
PDU3EVN3L1530B AG-00BA
PDU3EVN6L1530B AG-00BA
PDU3EVN10L1530B AG-00BA
PDU3EVN3L2130B AG-00BA
PDU3EVN6L2130B AG-00BA
PDU3EVN10L2130B AG-00BA
PDU3EVN6G60C AG-00BB
200 – 240V
SWITCHED
MODELS SERIES NO.
PDU3EVSR6H50 AG-00BA
PDU3EVSR10H50 AG-00BA
PDU3EVSR6L1530 AG-00BA
PDU3EVSR10L1530 AG-00BA
PDU3EVSR6L2130 AG-00BA
PDU3EVSR10L2130 AG-00BA
PDU3EVS6H50 AG-00BA
PDU3EVS6L2130 AG-00BA
PDU3EVS6L2120 AG-00BC
PDU3EVSR6L2120 AG-00BC
PDU3EVSR6L1520 AG-00BC
380 – 415V
MONITORED
MODELS SERIES NO.
PDU3XEVN6G20 AG-00BD
380 – 415V
SWITCHED
MODELS SERIES NO.
PDU3XEVSR6G20 AG-00BD
PDU3XEVSR6G30A AG-0096
PDU3XEVSR6G30B AG-0096
PDU3XEVSR6G32A AG-0096
PDU3XEVSR6G32B AG-0080
PDU3XEVSR6G60A AG-0096
PDU3XEVSR6G60B AG-0093
PDU3XEVSR6G63A AG-0096
PDU3XEVSR6G63B AG-0094
PDU3XEVSR6L230B AG-0056
PDU3XEVSR6L2230 AG-0096
PDU3XEVSRHWA AG-0096
PDU3XEVSRHWB AG-0057
*Varies by product.
Español 18 • Français 35 • 52Русский
18-05-347-93349E.indb 1 6/27/2018 10:57:05 AM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation, and storage of this product. Failure to heed these
instructions and warnings may affect the product warranty.
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes and that is
adequately protected against excess currents, short circuits and earth faults.
• The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the PDU should not draw more current than the individual
PDU’s outlet’s rating.
• The total load connected to the PDU must not exceed the maximum load rating for the PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
18-05-347-93349E.indb 2 6/27/2018 10:57:05 AM
1-1 1-2
1-4
1-3
1-5
A
B
3
Installation
Mounting the PDU
Note: The illustrations may differ somewhat from your PDU model. Regardless of configuration, the user must
determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed
for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting
configurations may vary. Screws for attaching the mounting brackets to the PDU are included. Use only the screws
supplied by the manufacturer or their exact equivalent.
Note: Mounting buttons come preinstalled to the PDU for toolless mounting.
1-1 To attach the mounting brackets to the
PDU, remove the mounting buttons.
1-2 Attach the mounting brackets to the
PDU with the included screws.
1-3 Attach the PDU to a vertical rail in
your rack or rack enclosure. (Use the
mounting hardware that came with your
rack or rack enclosure to attach the
mounting brackets to the rail.)
1-4 To reinstall the mounting buttons for
toolless mounting, remove the mounting
brackets then install the mounting
buttons onto the PDU. Position the PDU
as desired in the rack enclosure, align
the buttons with the rack mounting
slots, and slide the PDU into position.
Note: Be sure to insert the 2 buttons into either
the upper hole at of the PDU or into each end
the lower hole at of the PDU.each end
1-5 To install the PDU with its outlets facing
the rear of the rack, use the included
PDUMVROTATEBRKT accessory. First,
attach the mounting button A to the
V-shaped bracket B using the included
screw and washer. Then, use the
button-mount slot to attach the bracket
to the PDU and the mounting button to
attach the PDU to the rack. The bracket
effectively repositions the mounting
brackets allowing for the PDU outlets to
face the rear of the rack.
18-05-347-93349E.indb 3 6/27/2018 10:57:07 AM
Product specificaties
Merk: | Tripp Lite |
Categorie: | Stekkerdoos |
Model: | PDU3EVN6L2120 |
Kleur van het product: | Zwart |
Gewicht: | 6120 g |
Breedte: | 55.1 mm |
Diepte: | 64 mm |
Hoogte: | 1778 mm |
Snoerlengte: | 1.83 m |
Gewicht verpakking: | 8050 g |
Breedte verpakking: | 245.1 mm |
Diepte verpakking: | 1927.1 mm |
Hoogte verpakking: | 180.1 mm |
Soort: | Driefasig |
Gebruikershandleiding: | Ja |
Materiaal behuizing: | Metaal |
LED-indicatoren: | Ja |
Beeldscherm: | LCD |
Land van herkomst: | Taiwan |
Aantal Ethernet LAN (RJ-45)-poorten: | 2 |
Aantal USB-aansluitingen: | 3 |
Certificering: | UL60950-1, CAN/CSA, FCC CLASS A PART 15, NOM, TAA |
Duurzaamheidscertificaten: | RoHS |
Temperatuur bij opslag: | -30 - 60 °C |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Maximaal vermogen: | 5800 W |
Montage: | Verticaal |
Stekker: | NEMA L21-20P |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
Rackcapaciteit: | 0U |
AC-ingangsfrequentie: | 50/60 Hz |
Bedrijfstemperatuur (T-T): | 0 - 50 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Aantal AC uitgangen: | 45 AC-uitgang(en) |
Nominale input voltage: | 208 V |
Stopcontacttypes: | C13 coupler, C19 coupler, NEMA 5–15R, NEMA 5–20R |
Stroom (max.): | 16 A |
PDU types: | Gecontroleerd |
Netspanning, in bedrijf: | 120, 208 V |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite PDU3EVN6L2120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stekkerdoos Tripp Lite
30 Mei 2023
29 Mei 2023
26 Mei 2023
25 Mei 2023
23 Mei 2023
21 Mei 2023
18 Mei 2023
4 Mei 2023
4 Mei 2023
3 Mei 2023
Handleiding Stekkerdoos
- Stekkerdoos Apc
- Stekkerdoos Bachmann
- Stekkerdoos Brennenstuhl
- Stekkerdoos Digitus
- Stekkerdoos Eaton
- Stekkerdoos Eglo
- Stekkerdoos Eminent
- Stekkerdoos Ewent
- Stekkerdoos Furman
- Stekkerdoos Gembird
- Stekkerdoos Hama
- Stekkerdoos HQ
- Stekkerdoos Icy Box
- Stekkerdoos Konig
- Stekkerdoos Kopp
- Stekkerdoos Nedis
- Stekkerdoos Ufesa
- Stekkerdoos Oregon Scientific
- Stekkerdoos Caliber
- Stekkerdoos GoGEN
- Stekkerdoos Steren
- Stekkerdoos Ubiquiti Networks
- Stekkerdoos Sven
- Stekkerdoos REV
- Stekkerdoos Bauhn
- Stekkerdoos Kondator
- Stekkerdoos Intellinet
- Stekkerdoos Energenie
- Stekkerdoos CyberPower
- Stekkerdoos Yato
- Stekkerdoos DataVideo
- Stekkerdoos Kindermann
- Stekkerdoos ATen
- Stekkerdoos Lanberg
- Stekkerdoos Anton/Bauer
- Stekkerdoos StarTech.com
- Stekkerdoos Legrand
- Stekkerdoos Panduit
- Stekkerdoos EVOline
- Stekkerdoos V7
- Stekkerdoos Oehlbach
- Stekkerdoos Geist
- Stekkerdoos Salicru
- Stekkerdoos Adam Hall
- Stekkerdoos Panamax
- Stekkerdoos Altronix
- Stekkerdoos Middle Atlantic
- Stekkerdoos Tecnoware
Nieuwste handleidingen voor Stekkerdoos
14 November 2024
15 Oktober 2024
15 Oktober 2024
1 Oktober 2024
6 September 2024
6 September 2024
10 Juli 2024
18 Juni 2024
26 Maart 2024
19 Maart 2024