Tripp Lite PDU15NETLX Handleiding
Tripp Lite
Stekkerdoos
PDU15NETLX
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDU15NETLX (20 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/20
1
Owner’s Manual
PDU15NETLX
Mini Switched PDU
120V, 50/60Hz AC Input and Output
(AG-019E)
Important Safety Instructions 2
Installation 3
Features 4
Configuration and Operation 6
Technical Support 6
Warranty and Product Registration 7
Español 8
Français 15
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved.
17-02-373-9336CA.indb 1 6/2/2017 2:08:37 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation, and storage of this
product. Failure to heed these instructions and warnings may
affect the product warranty.
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge
or line noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from
excess moisture, temperature extremes, conductive contaminants, dust or direct
sunlight.
• Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Code standards. Be sure to use the
proper overcurrent protection for the installation, in accordance with the plug/
equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes
and that is adequately protected against excess currents, short circuits and earth
faults.
• The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters
that eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently
installed without a plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the PDU should not draw more current than the
individual PDU’s outlet’s rating.
• The total load connected to the PDU must not exceed the maximum load rating for
the PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment
can reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended.
17-02-373-9336CA.indb 2 6/2/2017 2:08:37 PM
1-1
1-2
C
C
C
C
A
A
B
B
1-3
A
A
B
C
3
Installation
Mounting the PDU
The PDU supports three primary mounting configurations: 0U Rack (Vertical), Wall and
Under-Counter.
Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before
mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may
not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the
mounting brackets are included. Use only the screws supplied by the manufacturer or their exact equivalent
(#6-32, 3/16" flat head).
1-1 0U Rack Mounting: Use 2 screws
A to attach each of the 2
mounting brackets B to the PDU.
Mount the PDU vertically by
inserting 2 or more user-supplied
screws C through the mounting
brackets B and into mounting
points in the rack or rack
enclosure.
1-2 Wall Mounting: Use 2 screws A
to attach each of the 2 mounting
brackets B to the PDU. Mount
the PDU to the wall by inserting 2
or more user-supplied screws C
through the mounting brackets B
and into secure mounting points.
1-3 Under-Counter Mounting: Use 2
screws A to attach each of the 2
mounting brackets B to the PDU.
Mount the PDU under the counter
by inserting 2 or more user-
supplied screws C through the
mounting brackets B and into
secure mounting points.
17-02-373-9336CA.indb 3 6/2/2017 2:08:38 PM
Product specificaties
Merk: | Tripp Lite |
Categorie: | Stekkerdoos |
Model: | PDU15NETLX |
Kleur van het product: | Zwart |
Gewicht: | 1200 g |
Breedte: | 127 mm |
Diepte: | 43.9 mm |
Hoogte: | 177.8 mm |
Snoerlengte: | 1.8 m |
Gewicht verpakking: | 1490 g |
Breedte verpakking: | 212.1 mm |
Diepte verpakking: | 205 mm |
Hoogte verpakking: | 50 mm |
Soort: | Eenfasig |
Gebruikershandleiding: | Ja |
Materiaal behuizing: | Metaal |
LED-indicatoren: | Activity,Network,Power,Status |
Land van herkomst: | Taiwan |
Aantal Ethernet LAN (RJ-45)-poorten: | 2 |
Aantal USB-aansluitingen: | 1 |
Certificering: | UL 60950-1, CSA, NOM, TAA |
Duurzaamheidscertificaten: | RoHS |
Ondersteunde beveiligingsalgoritmen: | SNMP,SNMPv3 |
Temperatuur bij opslag: | -30 - 60 °C |
Reset button: | Ja |
Bedrijfstemperatuur, bereik: | 32 - 122 °F |
Hoogte, in bedrijf: | 0 - 3000 m |
Maximaal vermogen: | 15200 W |
Montage: | Verticaal |
Stekker: | NEMA 5–15P |
(Buitenste) hoofdverpakking hoogte: | 180.1 mm |
(Buitenste) hoofdverpakking breedte: | 430 mm |
(Buitenste) hoofdverpakking brutogewicht: | 17900 g |
(Buitenste) hoofdverpakking lengte: | 450.1 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 12 stuk(s) |
Rackcapaciteit: | 0U |
AC-ingangsfrequentie: | 50/60 Hz |
Bedrijfstemperatuur (T-T): | 0 - 50 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: | 10037332203264 |
Aantal AC uitgangen: | 2 AC-uitgang(en) |
Nominale input voltage: | 100; 120; 127 V |
Stopcontacttypes: | NEMA 5–15R |
Stroom (max.): | 15 A |
PDU types: | Geschakeld |
Netspanning, in bedrijf: | 100; 120; 127 V |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite PDU15NETLX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stekkerdoos Tripp Lite
30 Mei 2023
29 Mei 2023
26 Mei 2023
25 Mei 2023
23 Mei 2023
21 Mei 2023
18 Mei 2023
4 Mei 2023
4 Mei 2023
3 Mei 2023
Handleiding Stekkerdoos
- Stekkerdoos Apc
- Stekkerdoos Bachmann
- Stekkerdoos Brennenstuhl
- Stekkerdoos Digitus
- Stekkerdoos Eaton
- Stekkerdoos Eglo
- Stekkerdoos Eminent
- Stekkerdoos Ewent
- Stekkerdoos Furman
- Stekkerdoos Gembird
- Stekkerdoos Hama
- Stekkerdoos HQ
- Stekkerdoos Icy Box
- Stekkerdoos Konig
- Stekkerdoos Kopp
- Stekkerdoos Nedis
- Stekkerdoos Ufesa
- Stekkerdoos Oregon Scientific
- Stekkerdoos Caliber
- Stekkerdoos GoGEN
- Stekkerdoos Steren
- Stekkerdoos Ubiquiti Networks
- Stekkerdoos Sven
- Stekkerdoos REV
- Stekkerdoos Bauhn
- Stekkerdoos Kondator
- Stekkerdoos Intellinet
- Stekkerdoos Energenie
- Stekkerdoos CyberPower
- Stekkerdoos Yato
- Stekkerdoos DataVideo
- Stekkerdoos Kindermann
- Stekkerdoos ATen
- Stekkerdoos Lanberg
- Stekkerdoos Anton/Bauer
- Stekkerdoos StarTech.com
- Stekkerdoos Legrand
- Stekkerdoos Panduit
- Stekkerdoos EVOline
- Stekkerdoos V7
- Stekkerdoos Oehlbach
- Stekkerdoos Geist
- Stekkerdoos Salicru
- Stekkerdoos Adam Hall
- Stekkerdoos Panamax
- Stekkerdoos Altronix
- Stekkerdoos Middle Atlantic
- Stekkerdoos Tecnoware
Nieuwste handleidingen voor Stekkerdoos
14 November 2024
15 Oktober 2024
15 Oktober 2024
1 Oktober 2024
6 September 2024
6 September 2024
10 Juli 2024
18 Juni 2024
26 Maart 2024
19 Maart 2024