C360 DDC HARD TUBE LIQUID COOLING KIT
1
01 01
09
02
02
CPU Water Block Installation Guide
05
05
04
08
03
Intel LGA2066,2011-3,2011
AMD
AM5
AM4/AM3/AM2/FM2/FM1
04
06
03
03 03
05
07
01
07
05
01
06
07
07
01
01
Intel LGA 1700/1200/115X
Intel AMD AM AM FM FM3/ 2/ 2/ 1
AM4
a
b
a
b
AMD
AMD
LGA1200/1156/1155/
1151/1150
LGA1700
a
b
ab
INTEL
INTEL
09
10
10
37
10
10
Please rem ove the stock AMD mounting
bracket, u se AM D bac kplate .
C360 DDC HARD TUBE LIQUID COOLING KIT
3
2
Installation Guide
CAUTIONS: 1. Make sure there is enough space when you start to set up the LCS product
2. Please use the wrench to install/ uninstall the base parts during all the installation
To ensure a clean loop, flush and rinse your radiators
and water blocks with distilled water before using.
Make sure the fittings are screwed securely when
placing them onto the radiator.
Attach the fittings to the inlet and outlet of the
water block.
Radiator
Fitting Water Block
Installation Walkthrough (Example: A500 TG)
Place the motherboard into the case. Position the radiator. Attach the pump and reservoir into
the chosen locations.
1
Nut
O Ring-
Packing
Base Base
Dismantle the fitting by using the wrench
1
2
2
25 27
27
01
26
27
23
22
21
Attach the fans to the radiator
Case Fan
20
24
Connect the PWM
cable to motherboard. 31
Connect the fan power cable to PWM cable
2031
21
Connect the fan power cable when the liquid cooling system
is completely finished
or
Choose the proper way to mount the pump and reservoir by referring to the manual
(suggest vertical placement) Attach fittings onto the pump and reservoir
Pump / Reservoir
26
27
27
12
12
12
15
14
18
13
15
16
16
14
C360 DDC HARD TUBE LIQUID COOLING KIT
Cutting and Attaching the Tubing
Measure the tube length based on the base
part of the fitting, and make (bend) the tubes.
The loop order : Pump Outlet > Water Block
Measure the tube length based on the base
part of the fitting, and make (bend) the tubes.
The loop order : Water Block > Radiator
Measure the tube length based on the
base part of the fitting, and make (bend)
the tubes. The loop order : Radiator >
Reservoir inlet
Fit the C-Pro fitting to the tube according
to the order in the picture below, Install the
tubes and tight the fitting caps.
Finished
3
3
2
2
1
1
4 5
Filling the System
CAUTIONS:
1. Before filling the system, please make
sure that each fitting as well as unused
ports are completely sealed.
2. If there is any case of leaking,
immediately turn off the power and
clean the leak
3. If there is any related electronic parts
stained on liquid coolant, make sure to
completely clean and dry the
components. And then make sure they
all work well.
After switching off the power supply,
connect the PSU power cord and
product cables.
Use the refill bottle to fill coolant into the reservoir
Place your PSU outside of the case and attach it to
the pumps 4pin molex connector, turn on the power
of PSU and make the rest of the system fills up.
C
C
C
CA
A
A
AU
U
U
UT
T
T
TI
I
I
IO
O
O
ON
N
N
N
CA U TIO N
The O-ring and the packing
with a groove on the inside
diameter must always be
installed towards the top of
the compression nut
Groove
3
28
27
34 35
Thermaltake recommends the following steps to be taken after completing your water loop setup
1. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance
while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
2. Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
3. DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
4. Fill the reservoir to the top as it will prevent air from going into the pump
5. If necessary tilt the system slightly from side to side to bleed the air out of the loop.
6. Place some paper towels under fittings and joining points to test for leaks.
7. Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.
© 2022 Thermaltake Technology Co., Ltd. All Rights Reserved. www.thermaltake.com


Product specificaties

Merk: Thermaltake
Categorie: Hardwarekoeling
Model: Pacific C360 DDC
Breedte: 200 mm
Diepte: 232 mm
Hoogte: 520 mm
Soort: Kit voor vloeistofkoeling
Aantal per verpakking: 1 stuk(s)
Slang diameter: 16 mm
Geschikte locatie: Moederbord
Code geharmoniseerd systeem (HS): 84733080
Pomp motor snelheid (max): 1500 RPM
Supported processor sockets: LGA 1150 (Socket H3), LGA 1151 (Socket H4), LGA 1155 (Socket H2), LGA 1156 (Socket H), LGA 1366 (Socket B), LGA 2011 (Socket R), LGA 2066, LGA 775 (Socket T), Socket AM2, Socket AM3, Socket AM3+, Socket AM4, Socket FM1, Socket FM2
Pulsbreedtemodulatie-ondersteuning: Ja
Pomp motor snelheid (min): 500 RPM
Radiator breedte: 119 mm
Radiator diepte: 399 mm
Radiator hoogte: 295 mm