1 I56-2358-004
06-10
INSTALLATION AND MAINTENANCE INSTRUCTIONS
BEAMMMK
Multi-mounting Kit for use with
Reective Projected Beam Smoke Detectors
3825 Ohio Avenue, St. Charles, Illinois 60174
800/736-7672, FAX: 630/377-6495
www.systemsensor.com
MOUNTING AND WIRING INSTRUCTIONS:
TRANSMITTER/RECEIVER
The BEAMSMK accessory must be used with the transmitter/receiver to pro-
vide wiring entry. Refer to Figures 2 through 4 for this step.
1. Read the installation instructions of the beam detector to determine the
appropriate size and number of wires to be used.
2. Drill the appropriate holes for the flexible conduit using the drill centers
provided on either the sides or the back of the surface mount base. See
Figure 2 for details. Note that the top of the surface mount base contains
mounting bosses for the “L” brackets used in the next step. Conduit sizes
of 1/2″ or 3/4″ are acceptable.
3. Assemble the “L” brackets to the surface mount base using the two #10-
24 × 5/8″ screws and two #10 split-lock washers provided. See Figure 3 for
details. The screws should be fully tightened.
4. Assemble the “U” bracket to the “L” brackets using the two #10-24 ×
1/2″ screws and fender washers provided. See Figure 3 for details. The
“U” bracket should be assembled to the “L” brackets so that the words
“DO NOT PAINT” appear in the front of the assembly. Tighten the screws
until almost snug. The assembly should tilt freely in either direction. The
screws will be fully tightened later when the alignment is performed.
5. Insert the flange of the “U” bracket into the keyed hole of the wall or ceil-
ing mount bracket. Slide the bracket forward into position. The surface
mount base should now hang from the bracket.
6. Insert the correct screw and washer combination (either wall or ceil-
ing mount) through the slot and into the hole of the mounting bracket
flange. Tighten the screw until almost snug. The assembly should still
Notice: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
The BEAMMMK allows reflected beam detectors and reflectors to be mounted
to either a vertical wall or the ceiling. The kit allows for additional alignment
range in cases where the detector and reflector cannot be mounted within
10° of each other. The kit includes the hardware necessary to mount either
a single transmitter/receiver unit or a single reflector. (To mount the trans-
mitter/receiver the surface mount kit, BEAMSMK, must also be used). If the
transmitter/receiver and the reflector require additional alignment range two
kits are required. The kit is not compatible with the long-range reflector kit
(BEAMLRK).
The kit includes the following parts:
Qty. Description
1 Ceiling mount bracket inside
1 Ceiling mount bracket outside
1 Wall mount bracket
1 “U” bracket
2 “L” bracket
1 Horizontal adjustment screw (ceiling) #10-24 × 2 1
/
4″
1 Horizontal adjustment screw (wall) #10-24 × 13/
8″
2 Allen screw #10-24 × 1
/2″
2 Allen screw #10-24 × 5
/8″
2 Fender washer plastic
2 Fender washer metal
2 Washer plastic #10
2 Washer metal #10
2 Washer metal split-lock #10
2 Hex nut #10-24
1 Allen wrench
MOUNTING BRACKETS
Install a ceiling or wall bracket so that when mounted, the transmitter/re-
ceiver and the reflector will have a clear line of sight between them.
The ceiling bracket is composed of two parts that should be assembled with
the inside part between the ceiling and the outside part as shown in Figure 1.
The brackets should be mounted so that the slot in the front of each bracket
is facing the other bracket. Mount the brackets only on solid structures of the
building. To avoid unwanted alarms due to wall movement, do not mount to
flexible walls, such as sheet metal walls (see Mounting Locations section of
the transmitter/receiver manual for more details).
CEILING
SCREWS
SLOT IN FRONT
OF BRACKET
OUTSIDE
PART
INSIDE
PART
CEILING
FIGURE 1. CEILING MOUNT BRACKET ASSEMBLY:
C0315-00
I56-2358-004
2 I56-2358-004
©2016 System Sensor. 06-10
turn freely in both directions. The screw will be fully tightened later
when the alignment is performed.
7. Pull the wiring and the flexible conduit through the drilled hole(s). At-
tach nut(s) (not included) to conduit fitting and tighten.
NOTE: Be sure to leave enough wire to reach the transmitter/receiver unit
when attached to the surface mount base. Be sure to leave enough flexible
conduit so that the transmitter/receiver unit can be adjusted to aim at the
reflector.
8. Attach the transmitter/receiver unit securely to the base using the four
#8-32 × 1/2″ screws supplied with the BEAMSMK accessory.
9. Adjust the transmitter/receiver unit so that it is aiming directly at the
reflector. Once aimed correctly fully tighten both vertical and horizontal
adjustment screws.
NOTE: For proper operation of the beam detector it must be securely mounted
to ensure no subsequent movement of the beam detector will occur after the
installation is completed. See “Detector Placement and Mounting” sections of
the beam detector manual for further details.
10. Complete the installation of the transmitter/receiver unit using the instruc-
tions included with the beam detector.
11. Test the system as indicated in the beam detector instructions.
MOUNTING INSTRUCTIONS: REFLECTOR
Refer to Figure 4 for this step.
1. Assemble the “L” brackets to the reflector using the two #10-24 ×
5/8″
screws, two #10 split-lock washers, and two #10 locknuts provided. See
Figure 4 for details. The screws should be fully tightened.
2. Assemble the “U” bracket to the “L” brackets using the two #10-24 ×
1/2″ screws and fender washers provided. See Figure 4 for details. The
“U” bracket should be assembled to the “L” brackets so that the words
“DO NOT PAINT” appear in the front of the assembly. Tighten the screws
until almost snug. The assembly should tilt freely in either direction. The
screws will be fully tightened later when the alignment is performed.
3. Insert the flange of the “U” bracket into the keyed hole of the wall or ceil-
ing mount bracket. Slide the bracket forward into position. The reflector
should now hang from the bracket.
4. Insert the correct screw and washer combination (either wall or ceil-
ing mount) through the slot and into the hole of the mounting bracket
flange. Tighten the screw until almost snug. The assembly should still
turn freely in both directions. The screw will be fully tightened later
when the alignment is performed.
5. Adjust the reflector so that it is aiming directly at the transmitter/receiver
unit. Once aimed correctly fully tighten both vertical and horizontal ad-
justment screws.
NOTE: For proper operation of the beam detector the reflector must be se-
curely mounted to ensure no subsequent movement will occur after the instal-
lation is completed. See “Detector Placement and Mounting” sections of the
beam detector manual for further details.
6. Test the system as indicated in the beam detector instructions.
FIGURE 2. BEAMSMK WIRING LOCATIONS:
FIGURE 3. WALL MOUNTING TRANSMITTER/RECEIVER UNIT:
Fender Washer – Metal
Fender Washer – Plastic
Vertical Adjustment
Screw #10-24 ×1/2″
#10-24 ×5/8″
#10 Split-lock Washer
“L” Bracket
DO NOT PAINTDO NOT PAINT
Horizontal
Adjustment Screw
#10-24 1×3/8″Metal Washer
Mounting Hub
“U” Bracket
Wall Mounting
Bracket
Mounting Hole
Plastic Washer
C0312-00
Drill for conduit
C0318-00
FIGURE 4. CEILING MOUNTING REFLECTOR:
DO NOT PAINT
DO NOT PAINT
Fender Washer– Metal
Fender W
asher – Plastic
Vertical Adjustment
Screw #10-24 ×1
/2″
#10 Hex Nut
#10 Split-lock Washer
“L” Bracket
Horizontal
Adjustment Screw
#10-24 2×1/4″Metal Washer
Mounting Hub
“U” Bracket
Mounting Holes
Plastic Washer
#10-24 ×5/8″
C0313-00
Product specificaties
Merk: | System Sensor |
Categorie: | Detector |
Model: | BEAM-MMK |
Kleur van het product: | Beige |
Montagewijze: | Opbouwmontage |
Heb je hulp nodig?
Als je hulp nodig hebt met System Sensor BEAM-MMK stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Detector System Sensor
24 Juli 2023
30 Juni 2023
26 Juni 2023
1 Juni 2023
1 Juni 2023
15 Mei 2023
Handleiding Detector
- Detector Bosch
- Detector Garmin
- Detector Gigaset
- Detector Honeywell
- Detector Pioneer
- Detector Abus
- Detector Alecto
- Detector Amprobe
- Detector AngelEye
- Detector Axis
- Detector Beha-Amprobe
- Detector Brennenstuhl
- Detector BRK
- Detector Denver
- Detector Dometic
- Detector Duro
- Detector Ebode
- Detector Elro
- Detector Extech
- Detector Ferguson
- Detector Ferrex
- Detector FireAngel
- Detector Flir
- Detector Fluke
- Detector Gamma Scout
- Detector Gossen
- Detector Grothe
- Detector Hager
- Detector Hikvision
- Detector Iget
- Detector Konig
- Detector Laserliner
- Detector Maginon
- Detector Marquant
- Detector Mercury
- Detector Metrix
- Detector National Geographic
- Detector Nedis
- Detector Netatmo
- Detector PCE Instruments
- Detector Powerfix
- Detector Pyle
- Detector Royal Sovereign
- Detector Sanwa
- Detector Satel
- Detector Siedle
- Detector Silverline
- Detector Skil
- Detector Smartwares
- Detector Steinel
- Detector Techno Line
- Detector Toolcraft
- Detector Trotec
- Detector Uniden
- Detector V-Tac
- Detector Velleman
- Detector Voltcraft
- Detector X4-Tech
- Detector Xavax
- Detector Joy-it
- Detector Jung
- Detector Olympia
- Detector Optex
- Detector Black And Decker
- Detector Schwaiger
- Detector Soler And Palau
- Detector Safescan
- Detector Cobra
- Detector Sauter
- Detector Sun Joe
- Detector Techly
- Detector DSC
- Detector Fisher
- Detector Garrett
- Detector Genie
- Detector Tripp Lite
- Detector Nexa
- Detector EVOLVEO
- Detector Whistler
- Detector Vemer
- Detector Ei Electronics
- Detector FireX
- Detector GEV
- Detector AcuRite
- Detector Testo
- Detector Testboy
- Detector IFM
- Detector Kyoritsu
- Detector Dahua Technology
- Detector Busch-Jaeger
- Detector Popp
- Detector Homematic IP
- Detector X-Sense
- Detector Kreator
- Detector ORNO
- Detector Multimetrix
- Detector Vimar
- Detector Escort
- Detector ZKTeco
- Detector Inovonics
- Detector Guardian Avionics
- Detector Thitronik
- Detector Cavius
- Detector Chauvin Arnoux
- Detector Pentatech
- Detector Flow Smoke Detector
- Detector Benewake
- Detector BeeSecure
- Detector Resideo
- Detector SureCall
- Detector Schabus
- Detector Zircon
- Detector STI
- Detector HT Instruments
- Detector BlendMount
- Detector K40
- Detector Gewiss
- Detector Seco-Larm
- Detector Seaward
- Detector Silent Knight
- Detector S.E. International
- Detector Rocky Mountain
- Detector Skyscan
- Detector Bearware
- Detector Winland
- Detector Noyafa
Nieuwste handleidingen voor Detector
18 November 2024
17 November 2024
17 November 2024
16 November 2024
16 November 2024
15 November 2024
15 November 2024
15 November 2024
5 November 2024
11 September 2024