INSTALLATION AND MAINTENANCE INSTRUCTIONS
3825 Ohio Avenue, St. Charles, Illinois 60174
1-800-SENSOR2, FAX: 630-377-6495
www.systemsensor.com
BEFORE INSTALLING
Please read the System Smoke Detectors Application Guide, which provides
detailed information on detector spacing, placement, zoning, wiring, and spe-
cial applications. Copies of this application guide are available from System
Sensor. NFPA 72 guidelines should be observed.
NOTICE: This manual should be left with the owner/user of this equipment.
IMPORTANT: The detector used with this base must be tested and maintained
regularly following NFPA 72 requirements. The detector should be cleaned at
least once a year.
GENERAL DESCRIPTION
The B300-6 and B300-6-IV are plug-in detector bases intended for use in an
intelligent system, with screw terminals provided for power (+ and –), and
remote annunciator connections. Communication takes place over the power
lines (+ and –).
BASE TERMINALS
NO. FUNCTION
1 Power (–), Remote Annunciator (–)
2 Power (+)
3 Remote Annunciator (+)
FIGURE 1. TERMINAL LAYOUT
TERMINAL 1
TERMINAL 2
TERMINAL 3
C0127-07
MOUNTING
This detector base mounts directly to 4-inch square (with and without plaster
rings), 4-inch octagon, 3
1/2-inch octagon, and single gang junction boxes. To
mount, remove the decorative ring by turning it in either direction to unhook
the snaps, then separate the ring from the base. Install the base on the box
using the screws supplied with the junction box and the appropriate mounting
slots in the base.
Place the decorative trim ring on the base and rotate it in either direction until
it snaps into place. (See Figure 2.)
SPECIFICATIONS
Base Diameter: 6.1 inches (155 mm)
Base Height: 0.76 inches (19 mm)
Operating Temperature: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com.
Electrical Ratings:
Operating Voltage: 15 to 32 VDC
Standby Current: 170 µA
Listings: UL268
I56-6566-001
FIGURE 2. MOUNTING DETECTOR TO BOX
SNAP ON
DECORATIVE
RING
SCREWS
(NOT SUPPLIED)
DETECTOR
BASE
BOX
(NOT SUPPLIED)
C2036-01
INSTALLATION AND WIRING GUIDELINES (SEE FIGURE 3)
All wiring must be installed in compliance with all applicable local codes
and any special requirements of the authority having jurisdiction. Proper wire
gauges should be used. The conductors used to connect smoke detectors to
control panels and accessory devices should be color-coded to reduce the like-
lihood of wiring errors. Improper connections can prevent a system from re-
sponding properly in the event of a fire.
For signal wiring (the wiring between interconnected detectors), it is recom-
mended that the wire be no smaller than 18 AWG (0.823 mm²). Wire sizes up
to 12 AWG (3.31 mm²) may be used with the base.
Make electrical connections by stripping about
3/8 inch (10 mm) of insulation
from the end of the wire (use strip gauge molded in base). Then slide the wire
under the clamping plate and tighten the clamping plate screw. Do not loop
the wire under the clamping plate. (See Figure 4.)
Check the zone wiring of all bases in the system before installing the detec-
tors. This includes checking the wiring for continuity, correct polarity, ground
fault testing and performing a dielectric test.
The base includes an area for recording the zone, address, and type of detec-
tor being installed. This information is useful for setting the detector head
address and for verification of the detector type required for that location.
Once all detector bases have been wired and mounted, and the loop wiring
has been checked, the detector heads may be installed in the bases.
B300-6 and B300-6-IV
6" Plug-in Detector Bases
1 I56-6566-001
11/17/2017
System Sensor warrants its enclosed smoke detector base to be free from defects in ma-
terials and workmanship under normal use and service for a period of three years from
date of manufacture. System Sensor makes no other express warranty for this smoke
detector base. No agent, representative, dealer, or employee of the Company has the au-
thority to increase or alter the obligations or limitations of this Warranty. The Company’s
obligation of this Warranty shall be limited to the repair or replacement of any part of
the smoke detector base which is found to be defective in materials or workmanship
under normal use and service during the three year period commencing with the date of
manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672)
for a Return Authorization number, send defective units postage prepaid to: Honeywell,
12220 Rojas Drive, Suite 700, El Paso TX 79936 USA. Please include a note describing the
malfunction and suspected cause of failure. The Company shall not be obligated to repair
or replace units which are found to be defective because of damage, unreasonable use,
modifications, or alterations occurring after the date of manufacture. In no case shall the
Company be liable for any consequential or incidental damages for breach of this or any
other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by
the Company’s negligence or fault. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply
to you. This Warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
Please refer to insert for the Limitations of Fire Alarm Systems
THREE-YEAR LIMITED WARRANTY
System Sensor® is a registered trademark of Honeywell International, Inc.
FIGURE 5A. ACTIVATE TAMPER-RESIST FEATURE
PLASTIC LEVER
BREAK TAB AT DOTTED LINE BY
TWISTING WARD CENTER OF BASETO
C0130-00
FIGURE 5B. DETECTOR REMOVAL
USE SMALL-BLADED SCREWDRIVER PUSH TO
PLASTIC LEVER IN DIRECTION OF ARROW
C0130-00
FIGURE 6. CONNECTION TO REMOTE ANNUNCIATOR TERMINAL
STRIPPED WIRE
WIRE WITH SPADE LUG
C0116-00
TAMPER-RESIST FEATURE
NOTE: Do not use the tamper-resist feature if a removal tool will be used.
The detector base includes a tamper-resist feature that prevents removal of the
detector without using a small screwdriver or similar tool.
To activate this feature, use needle-nose pliers to break the tab on the detector
base as shown in Figure 5A. Then, install the detector.
To remove the detector from the base once the tamper-resist feature has been
activated, remove the decorative ring by rotating it in either direction and
pulling it away from the base. Then, insert a small screwdriver into the notch,
as indicated in Figure 5B, and press the plastic lever toward the mounting
surface before rotating the detector counterclockwise for removal.
The tamper-resist feature can be defeated by breaking and removing the plas-
tic lever from the base. However, this prevents the feature from being used
again.
REMOTE ANNUNCIATOR (RA100Z)
Connect the remote annunciator between terminals 1 and 3 using the spade
lug terminal included. The spade lug terminal is connected to the base termi-
nal as shown in Figure 6.
It is not acceptable to have three stripped wires under the same wiring ter-
minal unless they are separated by a washer or equivalent means. The spade
lug supplied with the model RA100Z is considered an equivalent means. See
Figure 3 for proper installation.
FIGURE 3. TYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP
2
31
2
33
1
2
1
(–)
(+)
+ -
UL LISTED COM TIBLEPA
CONTROL PANEL
CAUTION: DO NO LOOP WIRE T
UNDER TERMINAL 1 OR 2.
BREAK WIRE RUN PROVIDE TO
SUPERVISION OF CONNECTIONS.
CLASS A OPTIONAL WIRING
REMOTE
ANNUNCIATOR
(–)
(+)
C0129-02
FIGURE 4. TERMINAL WIRE INSTALLATION
C0473-00
2 I56-6566-001
©2017 System Sensor. 11/17/2017


Product specificaties

Merk: System Sensor
Categorie: Detector
Model: B300-6-BP

Heb je hulp nodig?

Als je hulp nodig hebt met System Sensor B300-6-BP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Detector System Sensor

Handleiding Detector

Nieuwste handleidingen voor Detector