Sunding JOY-651 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Sunding JOY-651 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
3~5mm
TIRE SIZE
CIRC
TIRE SIZE
CIRC
12x1.75 935
12x1.95 940
14x1.50 1020
14x1.75 1055
16x1.50 1185
16x1.75 1195
16x2.00 1245
16x1-1/8 1290
16x1-3/8 1300
17x1-1/4 1340
18x1.50 1340
18x1.75 1350
20x1.25 1450
20x1.35 1460
20x1.50 1490
20x1.75 1515
20x1.95 1565
22x1-3/8 1770
22x1-1/2 1785
24x1.75 1890
24x2.00 1925
24x2.125 1965
24x1(520) 1753
24x/34Tubular 1785
24x1-1/8 1795
24x1-1/4 1905
26x1(599) 1913
26x1.25 1950
26x1.40 2005
26x1.50 2010
26x1.75 2023
26x1.95 2050
26x2.10 2068
26x2.25 2070
26x2.35 2083
26x3.00 2170
26x1-1/8 1970
26x1-3/8 2068
26x1-1/2 2100
650C Tubular
26x7/8 1920
650x20C 1938
650x23C 1944
650x25C
26x1(571) 1952
650x38A 2125
650x38B 2105
27x1(630) 2145
27x1-1/8 2155
27x1-1/4 2161
27x1-3/8 2169
27.5x1.50 2079
27.5×1.95 2090
27.5x2.1 2148
27.5x2.25 2182
700x18C 2070
700x19C 2080
700x20C 2086
700x23C 2096
700x25C 2105
700x28C 2136
700x30C 2146
700x32C 2155
700Tubular 2130
700x35C 2168
700x38C 2180
700x40C 2200
700x42C 2224
700x44C 2235
700x45C 2242
700x47C 2268
29x2.1 2288
29x2.2 2298
29x2.3 2326
MAX SPD
AVS SPD
MAX TMP
MIN TMP
1
1.Speedmeter 2 Front Light 3 Anti-Theft 4 Speaker 5 Powe Bank. . . .
2
3
4561
2
3
4
5
6
1
34
SET(1)
0
MODE 2( )
LIGHT
2
7
7
-SPD CURRENT SPEED
-ODO ODOMETER
-DST TRIP DISTANCE
-MXS MAXIMUM SPEED
-AVS AVERAGE SPEED
-TM TRIP TIME
-TTM TOTAL TRIP TIME
-CLK CLOCK 12H/24H
-Th TEMPERATURE
-MAX Th MAXIMUM TEMPERATURE
-MIN Th MINIMUM TEMPERATURE
- “ ” “ COMPARATOR
-Km/Mile SELECTION
-SLEEP MODE
- “ MAINTENANCE ALERT
- SETTING TYRE CIRCUMFERENCE
-SETTING LAST VALUE OF ODOMETER/ODO
-SETTING TTM
- BACK LIGHT
-AUTO WAKE UP
To attach the speedometer sensor, use
the ties to secure it to the front fork.
Make sure the computer and the sensor
are on the same side of the fork and no
more than 60cm apart. The sensor
should have an arrow pointing at the
magnet. Follow the figure to install the
magnet on a spoke. The gap between
the sensor and the magnet should be
3 mm.
Notice
The magnet is designed for spokes
that are less than 2mm thick
Pass bicycle spokes through the
plastic hole on the bottom of the
magnet and tighten to secure
Installation diagram of magnet and Sensor
Computer
Magnet
Mounting Shoe
Sensor
Ties
SPD
The screen always shows the speed, which can go up to
99.9 km/h (m/h) with an accuracy of +/- 0.1 km/h (m/h).
SPD Comparator
During riding,“ ” and “ ”on screen indicates the current
speedis higher or lower than average speed(AVS)
ODO
The screen shows the total distance in ODO mode, which
can be 0 to 99999 km (mile). The value resets to 0 after
reaching the maximum limit.
DST
The bottom line shows the single trip distance in DST
mode, which can be 0 to 9999 km (m). The value resets to
0 after reaching the maximum limit.
TM
After resetting the data, the trip time starts from zero and
counts up to 999 hours. After that, it resets to zero and
counts again.
TTM
Total riding time for one trip .TTM ranges 0~99999hr.
Temperature
Shows the ambient temperature in Celsius or Fahrenheit.
TheCelsius range is -20 to 70 degrees. The Fahrenheit
range is -4 to 158 degrees.
Sleep Mode
If there is no signal input within 100 seconds, the meter will
automatically enter the sleep state.The screen will only display
the clock and power level. You can turn on the screen by
shaking the bike or pressing any key, the computer unit will
return to the last used mode and preseve all the data collected.
Care Reminder
When the riding distance is greater, than the set
maintenance distance. the icon will appear.
Auto Wake Up
When the device is in sleep mode, it will enter working mode
when viberation being detected.
Auto Backlight
COMPRTER UNIT INTERFACE
Clear All Data
In mode press the SET button any ,
for 3 seconds to clear all the data
includingthat for DST MAX/ AVS TM / / /
MAX TH/ MIN TH. ( except that for
CLK ODO RAT\ \ )
To set maintenance alert, press the MODE button to adjust the
flashing value. The adjustment values are: 200, 400, 600, 800. After
setting the alert, press the SET button to enter the. Anti-theft alarm
function password setting, see the back page for details of the
setting method. Maintenance symbol clearing: click MODE
button + SET button at the same time to clear the maintenance
symbol.
Maintenance Aalert Setting
To set the total riding time, press the MODE button to cycle through
the flashing digits and press the SET button to move to the next
digit. The default value is 00:00:00 and it can range from 0 to 9999
hours. After setting the total riding time, press the SET button to go
to the maintenance alert setting mode.
TTM (Single Trip Time) Setting
Odometer Setting
To set the odometer, press the MODE button to cycle through the
flashing digits and press the SET button to move to the next digit.
The default value is 0000 and it can range from 0 to 99999 km or
miles. After setting the odometer, press the SET button to go to the
total riding time setting mode.
Speed Unit Setting (KM/H)/(MILE/H)
To choose between kilometers per hour (km/h) or miles per hour (m/h)
for the speed unit, press the MODE button in the speed unit setting
mode. Then press the SET button to go to the tire circumference
setting mode.
To set the tire circumference, use the chart to the right to find
the data for your tire size. The default value is 2080 mm. Press
MODE button to cycle through the flashing digit and Press SET
button to confirm and move to next digit. The value can range
from 0 to 9999 mm. After finishing circurence setting, press
SET button to go to the odometer setting mode.
Tire Circumference Setting
In temperature unit setting mode press the MODE button to
select between Celsius or Fahrenheit . Then press the SET button
to go to the speed unit setting
Temperature Unit (C/F°) Setting
Time Format (24H) SETTING
Press and hold MODE key + SET key for 6
seconds, after the screen displays SLEEP,
computer will enter deep sleep mode.
Deep Sleep Setting
Deep Sleep Mode
Press and hold the mode key for 4 seconds to turn on
Backlight long Bright. Press and hold the mode key for 4
seconds and the Backlight long Bright will turn off. After the
computer enters the sleep mode the Backlight long Bright is
turned off.
Backlight Long Bright
The Smart Backlight will activate when there is insufficient
light. Press any button to turn on the Backlight for 5 seconds.
FRONT BACK
SPEED
TIM E
TRIP TIME
TRIP DISTANCE
TEMPERATURE
JOY-651 V0.1 Instruction Manual
FUNCTIONS
HEAD UNIT ILLUSTRATION
COMPONENT ILLUSTRATIONS
BICYCLE COMPUTER FUNCTIONS
Remote Control
Charging cable
Tighten nut to scure the unIt.
MODE INSTRUCTION
DISPLAY MODE
Lean the base against the handlebars.
Push into the base in the direction of the
arrow, and the base snaps into place
Secure the horn button next to the
handlebar, and plug the cable
into the port on the speedmeter.
Buttons & Socket Description Diagram
Reset
Horn remote switch button
Horn connecting,Charing port External device charging port
Battery indicator
Clip
The screen is in display mode when riding, press MODE button to enter the query mode. 5 seconds later, it will return to
display mode automatically. When there is no signal input In the query mode, the top row switches between maximum speed
and average speed, and returns to the display mode automatically after 14 seconds.
Parameter setting
At the same time, press and hold MODE key + SET key for 4
seconds, then release the key, the meter will enter the clock setting
mode.In the clock setting mode, press MODE the hour digit will
blink, then press MODE key to adjust the value, press SET key to
confirm and enter the minute setting, after finishing, press SET key
to enter into temperature unit setting.
Maximum riding speed to the present after the single trip
value reset.
Average riding speed to the present after the single trip
value reset.
In the query mode, the maximum and minimum temperatures
are displayed in the lower right corner and are switched in a
frequency of 3 seconds. " " indicates the maximum
temperature.
In the query mode, when the " " symbol is displayed in the
lower right corner, it is the minimumtemperature.
The screen displays SLEEP, the wireless reception and auto
wake-up function is off.Press any key to enter the working
mode.
Functions
Long press MODE
+SET button for
4 seconds Enter
Settings
10 20 30 40 60 80 100 150
(Bright)
Front Light mode: \ \ ast lash ode ong ight Mode ight Control utomatic odeF F M L L L A M
Consistent Mode:Press "LIGHT" key when headlight is off, headlight will be on consistently.
Strobe Mode:Press "LIGHT" key in Consistent Mode, the headlights will flash at a frequency of one
second.
Auto Mode:Press "LIGHT" key in flash mode, the headlight enters into automatic modeWhen the
ambient light is dark, the headlight will light up automatically, and go out automatically when the ambient
light is strong.Note: When the battery power is less than 25%, to prioritize meter's power supply the
headlight will no longer work.
-Loud Alarm -Oen Key Control -Password Controlled -Password Change -Vibration Alarm
Malfunction
Troubleshooting Methods
Lowering or toning of the sound
The battery is low and needs to be recharged.
Anti-theft alarms goes off on accident
Bicycle not stabilized or otherwise disturbed by shaking
Rattling when moving the meter
Ball switch sound, normal phenomenon
The speedometer shows 0 km/h while
riding.
Improper magnet/sensor alignment, or the distance between
the computer and the sensor is more than 80cm.
Incorrect readings during use
Incorrectly set wheel circumference or metric and mile, reset to
correct value
Black display
Avoid exposing the device to direct sunlight or high temperature for too
long. Let it cool down in the shade for a while.
Display readout fades out
The battery voltage is low, change a new battery
Capacity: 4600mA/h
Open
Malfunction And Problems
-Loud Alarm
-Four S M ound odes
-Remote Control
FRONT LIGHT FUNCTION
ANTI-THEFT FUNCTION
SPEAKER FUNCTION
POWER BANK FUNCTION
Fast Flash Mode Long Light Mode Light Control Automatic Mode
Flowchart of meter operation
enters
anti-theft
Password
Setting
Operation diagram
Self locking
Enter Sentry Mode
When using the anti-theft device function, the code meter body can be rotate 20° to the right or left and
the body will not be able to pulled out of the base.
Press and hold
the "0" button for 4
seconds.
Shake detected
a. Press and hold the "0 key" for 4 seconds, the screen will display "START" and start blinking, and the
alarm will sound for two seconds to indicate entry of sentry mode.
b. In sentry mode, the alarm is triggered when shake is detected, the alarm sounds after 3 seconds, the
alarm stops after 12 seconds, and the meter remains in the sentry mode.
a. When charging the meter, please note that the working voltage is 5V, when the input voltage
exceeds 5V, it will cause the device to be damage and cannot be repaired.
b. Use or storage, keep the deviceaway from fire or water.
c. When the mobile power is not working, please do not
disassemble the meter by yourself, and send the meter to our company for repair.
a.The power indication has four levels, one level means 25%, two levels means 50%, three levels
means 75% and four levels means 100%.
b. When the battery is fully charged, the power indication is all lit and the charging circuit is
automatically disconnected to prevent overcharging.
c. When the using as a powerbank once the external device is fully charged. The meter will
automatically disconnect the charging circuit to protect the external device from being overcharged.
d.When the remaining battery is less than 25%, the meter will suspend the powerbank function and
prioritize meter's power supplye. When the remaining battery of the mobile power is less than 10%,
the battery symbol blinks, charge the battery as soon as possible
Insert the micro usb cable into the
charging port of the meter.
Pull off the silicone sealing cover under the
button of the meter body, and insert the charging
cable into the USB port.
Charging external devices
Charging the meter
1 Performance and Usage Notes.
2 Warning.
Electronic Horn
Press the horn remote switch, the horn will
make a loud, piercing beep. Press "0" to
switch between different sounds.
Forgetting your password
Click the reset button in the bottom hole with a pin to reset the password to the initial value: 00000.
Exit Sentry Mode
exit method: input the password directly to exit sentry mode regardless of the alarm state.
The screen displays "SUCEC". If the password is inputted wrongly for 3 times in a row, you can wait
for 15 seconds for the alarm to stop and input the password again.
Change password
Long press MODE key + SET key for 4 seconds to enter the parameter setting, the meter's will enter
the password setting page after parameter setting is completed, press the MODE key can be used to
enter the old password (initial password: 00000). Then the meter will enter new password setup
setting, enter the new password, then enter the new password again to confirm, if the two passwords
enter are the same then setup success and exit from the setting page.
use MODE key
to enter old
password
input setting enter old password enter new password
enter new password
again and meter will
enter working mode
Digital
Adjust
Option
switching
Digital
Adjust
Option
switching
Digital
Adjust
Option
switching
Digital
Adjust
Option
switching
Digital
Adjust


Product specificaties

Merk: Sunding
Categorie: Niet gecategoriseerd
Model: JOY-651

Heb je hulp nodig?

Als je hulp nodig hebt met Sunding JOY-651 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Sunding

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd