Stiebel Eltron WPL 15 A2W Premium Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Stiebel Eltron WPL 15 A2W Premium (44 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 133 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
OPERATION AND INSTALLATION
Air source heat pump
» WPL 15 A2W Premium
» WPL 25 A2W Premium
2 qT<ŨŝqTļ¼ăêşă ŷŷŷĪńŒê¼¼ùé¼ùŒļĒĉéşń|ĪĒă
CONTENTS
SPECIAL INFORMATION
OPERATION
1. General information ___________________________________________ 3
1.1 Relevant documents________________________________________________ 3
1.2 Safety instructions __________________________________________________ 3
1.3 Other symbols in this documentation __________________________ 4
1.4 Units of measurement _____________________________________________ 4
1.5 Standardized output data _________________________________________ 4
2. Safety ____________________________________________________________ 4
2.1 Intended use _________________________________________________________ 4
2.2 Safety instructions __________________________________________________ 4
3. Register your product _________________________________________ 5
4. Appliance description _________________________________________ 5
4.1 Properties ____________________________________________________________ 5
4.2 Function ______________________________________________________________ 6
5. Settings _________________________________________________________ 6
6. Maintenance and care _________________________________________ 7
7. Troubleshooting ________________________________________________ 7
INSTALLATION
8. Safety ____________________________________________________________ 8
8.1 General safety instructions _______________________________________ 8
8.2 Instructions, standards and regulations _______________________ 8
9. Appliance description _________________________________________ 8
9.1 Accessories ___________________________________________________________ 8
10. Preparation _____________________________________________________ 8
10.1 Sound emissions ____________________________________________________ 8
10.2 Minimum clearances _______________________________________________ 9
10.3 Installation near ocean/salt water______________________________10
10.4 Preparing the installation location _____________________________10
10.5 Installing the supply lines ________________________________________10
10.6 Siting _________________________________________________________________10
10.7 WPM heat pump manager _______________________________________12
10.8 Buffer tank __________________________________________________________12
10.9 Preparing the electrical installation ___________________________12
11. Installation _____________________________________________________13
11.1 Transport ____________________________________________________________13
11.2 Heating water connection ________________________________________13
11.3 Flow and return connection _____________________________________13
11.4 Fitting the push-fit connectors __________________________________14
11.5 Oxygen diffusion ___________________________________________________15
11.6 Filling the heating system _______________________________________15
11.7 Minimumow rate ________________________________________________15
11.8 Setting the flow rate on the heating side _____________________16
11.9 Condensate drain __________________________________________________17
11.10 External second heat generator ________________________________17
11.11 High limit safety cut-out for area heating system ___________17
12. Electrical connection __________________________________________17
12.1 Access to the terminal area ______________________________________17
12.2 WPL15/25A2W Premium ________________________________________19
12.3 Closing the terminal area ________________________________________19
12.4 Ribbon heater ______________________________________________________19
13. Commissioning ________________________________________________21
13.1 Checks before commissioning___________________________________21
13.2 Using the appliance with an external second heat
generator ____________________________________________________________21
13.3 Initial start-up ______________________________________________________22
13.4 Appliance handover _______________________________________________22
14. Settings ________________________________________________________22
14.1 Silent mode _________________________________________________________22
15. Appliance shutdown __________________________________________23
15.1 Standby mode ______________________________________________________23
15.2 Power interruption ________________________________________________23
16. Maintenance ___________________________________________________23
17. Troubleshooting _______________________________________________23
17.1 Checking the IWS DIP switch settings _________________________24
17.2 Light emitting diodes (LEDs) _____________________________________26
17.3 Reset button ________________________________________________________26
17.4 Resetting the high limit safety cut-out ________________________26
17.5 Fan noise ____________________________________________________________26
18. Specification ___________________________________________________28
18.1 Dimensions and connections ____________________________________28
18.2 Wiring diagram ____________________________________________________30
18.3 Application limit ___________________________________________________32
18.4 Output diagrams, WPL 15 A2W Premium _____________________33
18.5 Output diagrams, WPL 25 A2W Premium _____________________36
18.6 Data table ___________________________________________________________39
ZT.<.C%HVB`.HC
&¼ĉ¼ļ|ùêĉÏĒļă|ŒêĒĉ
ŷŷŷĪńŒê¼¼ùé¼ùŒļĒĉéşń|ĪĒă qT<ŨŝqTļ¼ăêşă 3
ZT.<.C%HVB`.HC
- The appliance may be used by children aged8
and older and persons with reduced physical,
sensory or mental capabilities or a lack of ex-
perience and know-how, provided that they
are supervised or they have been instructed
on how to use the appliance safely and have
understood the potential risks. Children must
never play with the appliance. Children must
never clean the appliance or perform user
maintenance unless they are supervised.
- The connection to the power supply must be
in the form of a permanent connection. Ensure
the appliance can be separated from the power
supply by an isolator that disconnects all poles
with at least 1/8˝ (3mm) contact separation.
- Maintain the minimum clearances to ensure
trouble-free operation of the appliance and fa-
cilitate maintenance work.
- Maintenance work, such as checking the elec-
trical safety, must only be carried out by a
qualified contractor.
- We recommend regular inspection (to establish
the current condition of the system), and main-
tenance by a qualified contractor if required (to
return the system to its original condition).
- Following disconnection from the power sup-
ply, parts of the appliance may remain ener-
gized for 2minutes until the inverter capacitors
have discharged.
- Never interrupt the power supply, even outside
the heating season. The system's active frost
protection is not guaranteed if the power sup-
ply is interrupted.
- If the heat pump is completely switched off and
there is a risk of frost, drain the system on the
water side.
HTV`.HC
1. General information
The chapters “Special information” and Operation” are intended
for both users and qualified contractors.
The chapter “Installation” is intended for qualified contractors.
Note
Read these instructions carefully before using the appliance
and retain them for future reference.
Pass on the instructions to a new user if required.
1.1 Relevant documents
Instructions for the WPM heat pump manager
Operating and installation instructions for system
components
Commissioning checklist for heat pump
1.2 Safety instructions
1.2.1 Structure of safety instructions
!
KEYWORD Type of risk
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
f Steps to prevent the risk are listed.
1.2.2 Symbols, type of risk
ăĒù `źĤ¼ĒÏļêń÷
Injury
Electrocution
1.2.3 Keywords
:tqHV B¼êĉÖ
DANGER Failure to observe this information will result in serious in-
jury or death.
WARNING Failure to observe this information may result in serious
injury or death.
CAUTION Failure to observe this information may result in non-serious
or minor injury.
!


Product specificaties

Merk: Stiebel Eltron
Categorie: Niet gecategoriseerd
Model: WPL 15 A2W Premium

Heb je hulp nodig?

Als je hulp nodig hebt met Stiebel Eltron WPL 15 A2W Premium stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Stiebel Eltron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024