Use and Care Manual
Electric Tankless Water Heaters
Page 1
17 West St., W. Hatļ¬eld, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info @stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
! DANGER: ELECTROCUTION
BEFORE PROCEEDING WITH ANY INSTALLATION,
ADJUSTMENT, ALTERATION, OR SERVICE, ALL CIRCUIT
BREAKERS AND DISCONNECT SWITCHES SERVICING
THE APPLIANCE MUST BE TURNED OFF. FAILURE TO DO
SO COULD RESULT IN SERIOUS PERSONAL INJURY OR
DEATH.
! DANGER: ELECTROCUTION
NEVER REMOVE THE APPLIANCEā€™S COVER UNLESS THE
ELECTRICITY SERVICING THE APPLIANCE IS TURNED OFF.
FAILURE TO DO SO COULD RESULT IN PERSONAL INJURY
OR DEATH.
All Tankless Models
Stiebel Eltron tankless water heaters are designed for a very
long service life. Actual life expectancy will vary with water
quality and use.
In areas with hard water that produces scale, descaling of
the entire unit may be required, and should be performed
as often as necessary. We recommend the Flow-Aide System
(Stiebel Eltron part # 540000) for this procedure. In these
areas, consideration should also be given to installing a ļ¬lter
that will prevent scale buildup on the cold water supply to
the water heater. We recommend the Scale TAC-ler Water
Conditioner (Stiebel Eltron part # 692442) for this.
Scale and dirt may build up in the ļ¬lter screen in the unit
and should periodically be removed. Following all directions
and precautions in this manual, regularly clean the ļ¬lter
screen and replace if necessary. Always shut off power to the
unit at the circuit breakers and water at the unitā€™s isolation
valves prior to removing the ļ¬lter screen.
Scale and dirt build up may also occur at the hot water out-
lets served by the unit, such as the faucet aerator, or shower
head. Keeping these ļ¬lter screens clean will ensure consis-
tent water ļ¬‚ow.
CLEANING: Use a damp cloth to clean of the unitā€™s housing.
Do not use any abrasive or corrosive cleaning agents.
Miniā„¢ and Miniā„¢-E Models
Following all directions and precautions in this manual,
regularly clean the ļ¬lter screen located in the cold water
inlet connection and replace if necessary. Descaling can be
done using a descaling solution or household vinegar.
To access the ļ¬lter screen in a Miniā„¢, always shut off power
to the unit at the circuit breakers and water at the unitā€™s
isolation valves prior to removing the ļ¬lter screen. Then
disconnect the cold water supply at the unit. Remove the
ļ¬lter screen by reaching up into the cold inlet pipe with a
small ļ¬‚athead screwdriver and while putting pressure on the
inside of the screenā€™s plastic rim, pull the screen down and
out. Clean and replace the ļ¬lter screen, or install a new one.
Never run the unit without the ļ¬lter screen in place.
Filter screen location in Miniā„¢
and Miniā„¢-E models
Filter screen
Front of unit
! DANGER: BURNS
WATER TEMPERATURES OVER 125Ā°F (51Ā°C) CAN CAUSE
SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
A HOT WATER SCALDING POTENTIAL EXISTS IF THE
THERMOSTAT ON THE APPLIANCE IS SET TOO HIGH.
HOUSEHOLDS WITH SMALL CHILDREN, DISABLED OR
ELDERLY PERSONS MAY REQUIRE THAT THERMOSTATS
BE SET AT 120 Ā°F (48 Ā°C) OR LOWER TO PREVENT
POSSIBLE INJURY FROM HOT WATER.
CAUTION: OTHER THAN THE FILTER SCREEN, THESE
APPLIANCES DO NOT CONTAIN ANY PARTS SERVICEABLE
BY THE LAY PERSON. IN CASE OF MALFUNCTION, PLEASE
CONTACT A LICENSED PLUMBER OR ELECTRICIAN.
CH
26_02_05_0065_
Use and Care Manual
Electric Tankless Water Heaters
Page 2
17 West St., W. Hatļ¬eld, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info @stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
To access the ļ¬lter screen in an older DHC model, always
shut off power to the unit at the circuit breakers and water at
the unitā€™s isolation valves prior to removing the ļ¬lter screen.
Then loosen nut at base of cold water supply tube. (Refer to
the illustration below.) Rotate cold water supply tube coun-
terclockwise 90 degrees and pull towards bottom of unit.
Clean screen and put the screen, the cold water supply tube
and the ground wire back into their original position. Be sure
the ground wire is reinstalled, the ground screw is securely
fastened, and the nut on the cold water supply tube is tight
before the unit is returned to service. Clean and replace the
ļ¬lter screen, or install a new one, into its original position.
Never run the unit without the ļ¬lter screen in place.
The outlet temperature of a DHC Trend can be limited to
several selectable internal values. Consult your installer if
your unit has been set to a limit and you require a higher
temperature.
1.
2.
90Ā°
ī˜
ī˜Œī˜†ī˜‹ī˜‰ī˜„ī˜†ī˜ˆ
ī˜
ī˜Ž
ī˜…ī˜ƒ
DHC models prior to 2015
a Location of ground wire
to be removed
b Rotate cold water sup-
ply tube after nut is
loosened
c Filter screen
- All DHC Classic & DHC
Trend models
- DHC models 2015 and
newer
Filter screen location in DHC and DHC
Classic/Trend models
Filter screen
DHC and DHC Classic/Trend Models
The ļ¬lter screen in DHC models is in one of two locations.
In all DHC Classic/Trend models, and DHC models from 2015
and newer, the screen is located in the cold water inlet con-
nection, the same as in a Miniā„¢, DHC-E, or TempraĀ®. In older
DHC models, the ļ¬lter screen is located in the top of the cold
water supply tube.
To access the ļ¬lter screen in a newer DHC model, always
shut off power to the unit at the circuit breakers and water at
the unitā€™s isolation valves prior to removing the ļ¬lter screen.
Then remove the cold water connection and pull the ļ¬lter
screen down and out of the unit. Clean and replace the ļ¬lter
screen, or install a new one, into its original position. Never
run the unit without the ļ¬lter screen in place.
Continued on next page ā€ŗ
Use and Care Manual
Electric Tankless Water Heaters
Page 3
17 West St., W. Hatļ¬eld, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info @stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
The amount of heat put into the water is controlled elec-
tronically in TempraĀ® and DHC-E models. Using the knob
on the front cover, set the output water temperature to any
temperature between 86 Ā°F (30 Ā°C) and 140 Ā°F (60 Ā°C). For
most applications we recommend setting only to the highest
temperature for normal use, typically 108Ā°F (42Ā°C) to 116Ā°F
(47Ā°C) for a shower. This lower setting will increase the life
of the unit.
The outlet temperature of a TempraĀ® Plus, DHC-E 8/10, or
DHC-E 12 model can be limited to 109 Ā°F (43 Ā°C). Consult your
installer if your unit has been set to this limit and you require
a higher temperature.
The outlet temperature of a DHC-E Trend or DHC-E Plus can
be limited to several selectable internal values. Consult your
installer if your unit has been set to a limit and you require a
higher temperature.
If the ā€œPowerā€ is ļ¬‚ashing on a DHC-E 8/10, DHC-E 12, led
DHC-E Trend, or TempraĀ® Trend unit while it is operating, the
water ļ¬‚ow rate exceeds the heating capacity of the unit. Re-
ducing the ļ¬‚ow of hot water or setting a lower temperature
will let the unit achieve the set point temperature.
Filter screen location in DHC-E models
Filter screen
DHC-E, DHC-E Trend/Plus, DHX models and Tempra
Ā® models
To access the ļ¬lter screen in any DHC-E/DHX model, always
shut off power to the unit at the circuit breakers and water at
the unitā€™s isolation valves prior to removing the ļ¬lter screen.
Then remove the cold water connection and pull the ļ¬lter
screen down and out of the unit. Clean and replace the ļ¬lter
screen, or install a new one, into its original position. Never
run the unit without the ļ¬lter screen in place.
To access the ļ¬lter screen in a TempraĀ® model, always shut
off power to the unit at the circuit breakers and water at the
unitā€™s isolation valves prior to removing the ļ¬lter screen.
Then remove the cold water inlet connection (right-hand side
when facing unit) and remove the washer (2). Next, pull the
ļ¬lter screen (1) down and out of the unit with needle nose
pliers. Clean and replace the ļ¬lter screen, or install a new
one, into its original position along with the washer. Never
run the unit without the ļ¬lter screen in place.
2
2
2
2
2
26_02_02_0877
1
1
1
1
1
Filter screen location in TempraĀ® models
Filter screen
Washer
ā€ŗ Video tutorial:
Cleaning a Filter Screen on TempraĀ® Water Heaters


Product specificaties

Merk: Stiebel Eltron
Categorie: Niet gecategoriseerd
Model: DHC Trend

Heb je hulp nodig?

Als je hulp nodig hebt met Stiebel Eltron DHC Trend stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Stiebel Eltron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024
Senal

Senal ME-220-CL Handleiding

21 November 2024
Senal

Senal ASM-4 Handleiding

21 November 2024
Senal

Senal CS-88 Handleiding

21 November 2024
Senal

Senal CSP-162 Handleiding

21 November 2024
Senal

Senal ASM-3 Handleiding

21 November 2024
Senal

Senal ASM-5 Handleiding

21 November 2024