Peerless ECMU-02-I-S Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Peerless ECMU-02-I-S (36 pagina's) in de categorie Flat panel steun. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
Installation and Assembly:
Wind Rated I-beam Tilt Mount for 32" - 65" Outdoor Flat Panel
Displays
Models: ECMU-01-I, ECMU-01-I-S, ECMU-02-I, ECMU-02-I-S
ECMU-03-I, ECMU-03-I-S, ECMU-04-I, ECMU-04-I-S
ISSUED: 06-22-10 SHEET #: 061-9055-6 01-15-11
Max UL Load Capacity: 200 lb (90.7 kg)
Max Wind Rating: 90 mph, elevation 200 ft, Category D
©
UL
USC
2 of 36 ISSUED: 06-22-10 SHEET #: 061-9055-6 01-15-11
NOTE: Read entire instruction sheet before you start installation and assembly.
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• Due to outdoor environmental conditions such as strong wind gusts, heavy snow, hail, rain, etc. The environmental
enclosure, together with its mount, extension tube and hardware, must be inspected at least once a year, and
immediately following any time winds exceed 90 mph. A quali ed installer or inspector must check for signs of rust,
loose fasteners, bent metal, etc. If evidence of excessive wear, deterioration or any unsafe condition is observed,
this product must be taken out of service immediately. Direct all inquiries to customer care if you have any
questions.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product was designed for use with other outdoor products only.
WARNING
Tools Needed for Assembly
• phillips screwdriver, 3/16" allen wrench
• level
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to I-beam ..............................................................................................................................................................4
Installing Tilt Brackets .............................................................................................................................................................7
Mounting and Removing Flat Panel Screen ...........................................................................................................................8
3 of 36 ISSUED: 06-22-10 SHEET #: 061-9055-6 01-15-11
ECMU-01-I
ECMU-02-I
ECMU-03-I
ECMU-04-I
ECMU-01-I-S
ECMU-02-I-S
ECMU-03-I-S
ECMU-04-I-S
Description Qty. Part # Part # Model # Part #
A
ceiling plate 1 061-T1283 061-7283 ECMU-01-I 061-T1266
Bsupport column 1 see chart see chart ECMU-01-I-S 061-7266
Cceiling clamp 2 061-T1281 061-7281 ECMU-02-I 061-T1267
Dadapter box 1 061-T1264 061-7264 061-7267ECMU-02-I-S
E5/16"-18 x 1" socket screw 4 520-5035 520-5035 ECMU-03-I 061-T1268
F7/16" x 4" hex head bolt 3 520-5014 520-5014 ECMU-03-I-S 061-7268
G7/16" nylock nut 3 530-5003 530-5003 ECMU-04-I 061-T1269
Hadapter plate 1 061-T1258 061-7258 ECMU-04-I-S 061-7269
I1/4-20 x .75" socket screw 8 520-5034 520-5034
Jleft tilt bracket 1 061-T1383 061-7383
K
right tilt bracket 1 061-T1382 061-7382
Lsecurity allen wrench 1 560-9646 560-9646
MM6 x 12 mm socket pin screw 4 520-5023 520-5023
NM6 x 25 mm socket pin screw 4 520-5024 520-5024
OM8 x 15 mm socket pin screw 4 520-5026 520-5026
PM6 x 20 mm socket pin screw 4 520-5025 520-5025
QM8 x 25 mm socket pin screw 4 520-5027 520-5027
R
washer 4 540-5014 540-5014
S1/2-13 x 2" square head screw 4 520-5036 520-5036
T1/2-13 x 4" bolt 12 520-5019 520-5019
U1/2-13 nylock nut 8 530-5005 530-5005
V1/2" washer 16 540-5010 540-5010
W5' wire rope (not shown) 1 560-0056 560-0056
Xcable clip 2 560-0069 560-0069
Y1/2-13 hex nut 4 530-5010 530-5010
Support Column (B)
Parts List
B
Parts may appear slightly different than illustrated.
Before you begin, make sure all parts shown are included with your product.
A
DFG
EI
H
J
K
M N O
R S T
UV
XY
P Q
L
C


Product specificaties

Merk: Peerless
Categorie: Flat panel steun
Model: ECMU-02-I-S
Kleur van het product: Grijs
Gewicht verpakking: 29900 g
Gebruikershandleiding: Ja
Montagewijze: Plafond
Maximale gewichtscapaciteit: 91 kg
Draaihoek: 360 °
Montage interface compatibiliteit (min): 600 x 400 mm
Montage interface compatibiliteit (max): 600 x 400 mm
Aantal displays ondersteund: 1
Bereik kantelhoek: 5 - 15 °
Maximale schermgrootte: 65 "
Minimale schermgrootte: 32 "
Maximum afstand tot plafond: 686 mm
Montage gatenpatroon (H x V): 720 x 449 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Peerless ECMU-02-I-S stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Flat panel steun Peerless

Handleiding Flat panel steun

Nieuwste handleidingen voor Flat panel steun