Contents
1 Safety notes .................................................................................................................... 1
2 Introduction .................................................................................................................... 2
3 Specicatio ns ................................................................................................................. 2
4 Symbol Denition and Button Location ........................................................................ 3
5 Operation Instructions ................................................................................................... 4
5.1 Power- Up ......................................................................................................................... 4
5.2 Connection of the temperature probe ............................................................................... 5
6 Selecting the Temperature Scale .................................................................................. 5
7 Data-Hold Operation ...................................................................................................... 5
8 Back light Operation ...................................................................................................... 5
9 Relative Operation 5 .........................................................................................................
10 MAX/MIN/AVG Operation ............................................................................................... 6
11 Auto Power O ............................................................................................................... 6
12 Low Battery Condition ................................................................................................... 6
13 Temperature Measurement ............................................................................................ 7
13.1 Correct Measurement Method .......................................................................................... 7
13.2 Connector Conguration 7 ..................................................................................................
14 Temperature Meter Calibration Setup ........................................................................... 8
15 Pt type selection ............................................................................................................. 9
16 0 °C Calibration .............................................................................................................10
17 Recall Default factory setting value .............................................................................11
18 Maintenance ..................................................................................................................13
18.1 Replacing the Batteries ...................................................................................................13
18.2 Cleaning ..........................................................................................................................13
19 Temperature Probe .......................................................................................................14
19.1 Piercing type temperature probe .....................................................................................14
19.2 Piercing type temperature probe Specication . ................................................................ 14
20 Delivery contents ..........................................................................................................14
21 Contact ........................................................................................................................15
22 Disposal .........................................................................................................................15
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time.
The device may only be used by qualied personnel and repaired by PCE Instruments
personnel. Damage or injuries caused by non-observance of the manual are excluded from our
liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used
otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature,
relative humidity, …) are within the ranges stated in the technical specications. Do
not expose the device to extreme temperatures, direct sunlight, extreme humidity or
moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualied PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral
cleaner, no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to
the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.


Product specificaties

Merk: PCE Instruments
Categorie: Thermometer
Model: PCE-T 318

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-T 318 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer PCE Instruments

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer

Owon

Owon TI219 Handleiding

21 December 2024
TFA

TFA 12.1004 Handleiding

21 December 2024
Optex

Optex PT-U80 Handleiding

16 December 2024
Optex

Optex PT-7LD Handleiding

16 December 2024
Ebro

Ebro TFI 260 Handleiding

15 December 2024
Ebro

Ebro TFI 54 Handleiding

15 December 2024
EMOS

EMOS E0522 Handleiding

13 December 2024
Senseca

Senseca PRO 111 Handleiding

11 December 2024