Panasonic VL-V566BX Handleiding
Panasonic
Intercomsystemen
VL-V566BX
Lees hieronder de 📖 handleiding in het Nederlandse voor Panasonic VL-V566BX (1 pagina's) in de categorie Intercomsystemen. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/1
1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan
© Panasonic System Networks Co., Ltd. 2010
Door Station
Model No. VL-V566BX
Installation and Operation Guide
Thank you for purchasing a Panasonic product.
LPlease read this guide before using the unit and save for
future reference.
LPlease read this guide carefully, and install the unit safely
and correctly by following the instructions. Panasonic
assumes no responsibility for injuries or property damage
resulting from failures arising out of improper installation or
operation inconsistent with this guide.
For your safety
To prevent severe injury and loss of life/property, read this section carefully
before using the unit to ensure proper and safe operation of your unit.
WARNING
L
To reduce the risk of electric shock, do not disassemble this unit. Refer
servicing to an authorized service center when service is required. Opening or
removing covers may expose you to dangerous voltages or other risks. Incorrect
reassembly can cause electric shock when the unit is subsequently used.
LNever install wiring during a lightning storm.
L
When existing chime wires are used, it is possible that they contain AC voltage.
Electric shock or unit damage could result. Contact an authorized service center.
CAUTION
LInstall the unit securely adhering to the instructions in this guide to prevent
it from falling off the wall. Avoid installing onto low-strength walls, such as
gypsum board, ALC (autoclaved lightweight concrete), concrete block, or
veneer (less than 18 mm thick) walls.
LIf the wiring is underground, do not make any connections underground.
LIf the wiring is underground, use a protection tube.
PNQW2397ZA SV0910MT0
For your future reference
Date of purchase
Serial number (found on the rear of the door station)
Dealer’s name and address
Dealer’s telephone number
Attach your sales receipt here.
Included accessories
LWood screws ..................2
(3.8 mm × 20 mm)
L Attached to the bag the door station
is in.
Location of controls
A Lens cover
B Camera
C {CALL} button and indicator
LThe indicator is lighted with a red LED
while the power is on.
LWhen a visitor presses the call button,
a ringer tone will ring.
D Water drain holes
LThese holes allow rain water to drain.
Do not cover them.
E Panel
F Speaker
G Microphone
A
B
C
D
E
F
G
N Door station image quality
The following phenomena may occur. They are not malfunctions.
LIf the sun can be seen, its center appears as a black dot.
LAt night or when there is poor lighting in the doorway, the image colors
become unclear. If there is a light in the doorway, the image may appear
greenish.
LDuring the daytime or if there is bright light in the doorway, the color of the
visitor’s clothing may appear differently to the actual color.
Before installation
To avoid malfunction or communication disturbances, do not install the door station
in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places near hydrogen sulfi de.
Installation position of the door station and camera range
N Views when the camera is facing forwards at 0° (default).
LExample: Installation height is 1450 mm (standard position).
Side view Top view
Image range:
960 mm
500 mm
87°
1450 mm
1810 mm
Center of
the door
station 66° 650 mm
Image
range
1160 mm
500 mm
Note:
LThe measurements and angles are for reference purposes and may vary
depending on the environment.
LIf a strong light is shining on the door station, the visitor’s face may not be
distinguishable.
Do not place the door station in the following locations.
– Where most of the background is the sky.
– Where the background is a white wall, and direct sunlight will refl ect off it.
– Where direct sunlight will shine on the door station.
LDo not place the door station in the locations where echoing occurs, causing the
unit to beep frequently.
L Make sure the rear of the door station is not subject to water.
Wire type and distance
LWire (between the main monitor station and the door station):
Type Distance Loop resistance
General cable CAT-3 Maximum 50 m 10 Ω or lower
General cable 22 AWG (ø 0.65) Maximum 100 m
The camera angle can be adjusted using the camera angle control lever on the
rear of the door station (step 3, “Installing the door station”), so that the image
range can be changed.
N
Side view when the camera is installed
lower than the standard position, and
facing upwards at 15°.
L
Example: Installation height is 1100 mm.
N
Top view when the camera is facing
left or right at 15° *1.
L
Example: Camera angle faces left 15°.
Center of
the door
station
1690 mm
1100 mm
66°
710 mm
500 mm
980 mm
Image
range
Image range:
1080 mm
810 mm
500 mm
87°
270 mm
*1 If the camera points 15° upwards, the left or right angle is less than 7°.
Installing the door station
Important:
LOn the bottom surface of the door station, there are holes to allow water to
drain. Do not cover them up when installing.
1 Remove the mounting base.
A Open the screw
cover.
TScrewdriver
Mounting base
B Loosen the
mounting screw.
Water drain
holes
2 Attach the mounting base to the wall securely using the wood screws (3.8
mm x 20 mm).
LInstall the mounting base on a vertical fl at wall.
LBefore drilling, refer to “Before installation” for installation location.
83.5 mm
Wall
Wire (Not included)
Mounting base
Wood screws
3 Adjust the camera angle using the camera angle control lever.
Important:
LWhen the camera angle is adjusted to the upper left or upper right, the
image may be slightly distorted.
LThe angle can also be adjusted to
the left or upper left.
<Examples of camera angle>
<Facing forwards> <Facing upwards> <Facing right> <Facing upper right>
Rear view Camera angle
control lever
Left
(maximum 15°)
Right
(maximum 15°)
Upwards
(maximum 15°)
4 Connect the wire, then mount the door station to the mounting base.
A Unscrew the screws.
Push in the wire to the terminal connectors
(non polar), then tightly fasten the screws.
Wire (connecting to the main monitor station)
C Fasten the screw,
then close the
screw cover.
B Mount the door station
to the mounting base.
Specifi cations
Power source: Supplied by the main monitor station
Dimensions:
Approx. height 131 mm x width 99 mm x depth 36.5 mm
(Excluding protruding sections)
Mass (Weight): Approx. 200 g
Operating environment: -10 °C to 50 °C, Up to 90 % RH (Relative Humidity) non
condensing
Installation method: Wall mount (Wall mount base included)
External material: Flame retardant ABS resin
Note:
LDesign and specifi cations are subject to change without notice.
LThe pictures and illustrations in these instructions may vary slightly from the
actual product.
Cleaning
Clean the unit with a soft, dry cloth when cleaning. For excessive dirt, wipe the unit
with a slightly damp cloth.
Important:
LDo not use anything containing alcohol, polish powder, powder soap,
benzine, thinner, wax, petroleum, or boiling water.
Also do not spray with insecticide, glass cleaner, or hair spray.
This could cause a change in color or quality.
PNQW2397ZA̲VL-V566BX̲工説.indd1-2
PNQW2397ZA̲VL-V566BX̲工説.indd1-2
PNQW2397ZA̲VL-V566BX̲工説.indd1-2
PNQW2397ZA̲VL-V566BX̲工説.indd1-2PNQW2397ZA̲VL-V566BX̲工説.indd1-2PNQW2397ZA̲VL-V566BX̲工説.indd1-2 2010/08/1917:06:47
2010/08/1917:06:47
2010/08/1917:06:47
2010/08/1917:06:472010/08/1917:06:472010/08/1917:06:47
Product specificaties
Merk: | Panasonic |
Categorie: | Intercomsystemen |
Model: | VL-V566BX |
Heb je hulp nodig?
Als je hulp nodig hebt met Panasonic VL-V566BX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Intercomsystemen Panasonic
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
Handleiding Intercomsystemen
- Intercomsystemen Abus
- Intercomsystemen Dahua
- Intercomsystemen Elro
- Intercomsystemen Marmitek
- Intercomsystemen Silvercrest
- Intercomsystemen DoorBird
- Intercomsystemen Extel
- Intercomsystemen M-e
Nieuwste handleidingen voor Intercomsystemen
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022
3 Oktober 2022