Ozito PXHDIS-018 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Ozito PXHDIS-018 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
STANDARD EQUIPMENT
AC
DC
I
0
I
+
MODE
I
AC
DC
I
0
I
+
MODE
I
PXHDIS-018
INSTRUCTION MANUAL
SPECIFICATIONS
Input: 18V
No Load Speed: 18,000/min
Max. Pressure: 160psi (11bar)
Flow Rate: 10L/min @ 4bar (58psi)
Weight: 1.8kg
ozito.com.au
1021
Cordless Inī˜Ÿator / Deī˜Ÿator &
High Volume Air Hose
3 x Inī˜Ÿation Adaptors
INFLATOR /
DEFLATOR
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU
MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS
WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE
OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL
NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER
SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND
ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE
WARRANTY POLICY OR PROCEDURE.
OZITO INDUSTRIES PTY. LTD. 25 Fox Drive, Dandenong South, Victoria, Australia 3175.
The beneī˜žts provided under this warranty are in addition to other rights and
remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to
a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this
warranty, however, where you have suffered any additional direct loss as a result of
a defective product you may be able to claim such expenses by contacting our
customer service helpline above.
WARNING
The following actions will result in the warranty being
void.
ā€¢ If the tool has been operated on a supply voltage other than that speciī˜žed
on the tool.
ā€¢ If the tool shows signs of damage or defects caused by or resulting from
abuse, accidents or alterations.
ā€¢ Failure to perform maintenance as set out within the instruction manual.
ā€¢ If the tool is disassembled or tampered with in any way.
5 YEAR REPLACEMENT WARRANTY
Your Product is guaranteed for a period of 60 months from the original date of
purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it
will be replaced in accordance with the terms of this warranty. Lithium Ion
batteries and chargers are covered by a 36 month
warranty and are excluded from the warranty extension. Warranty excludes
consumable parts.
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
DC
I
I
+
MODE
I
Attaching Inļ¬‚ation Adaptors
The inī˜Ÿator unit has 3 adaptors to allow a range of functions. All the
adaptors are secured in the compartment at the side of the unit.
1. Open the side compartment and
remove the desired inī˜Ÿation
adaptor.
2. Remove the high pressure air hose from
the back of the tool and unlock the nozzle
by lifting the locking lever.
3. Insert the adaptor into the hose
nozzle and lock by pushing down
the locking lever.
Attaching The High Volume Hose
When inī˜Ÿating, connect the high
volume hose to the ā€˜AIR OUTā€™ port.
When deī˜Ÿating, connect the hose to
the ā€˜AIR INā€™ port.
1. Align the cutouts in the hose
with the tabs in the desired port.
2. Insert the hose and twist
clockwise to lock the hose in
place.
3. Tug gently on the hose to ensure
it is installed securely.
1. Adaptor Storage
2. Manual Mode Switch
3. Carry Handle
4. Operation Mode Switch
5. High Volume Air Hose
6. Digital Display
7. Battery Seating
8. Pressure Selection Buttons
9. High Pressure Hose
10. Presta Adaptor
11. General Purpose Adaptor
12. Ball Adaptor
This tool is compatible with all batteries & chargers from the Ozito Power X Change
range.
CORDLESS INFLATOR / DEFLATOR
BATTERY & CHARGER
KNOW YOUR PRODUCT
1. CONNECTING ACCESSORIES
SETUP & PREPARATION
1 2 4 53
7 68
10
9
11 12
WARNING! ENSURE THE TOOL IS SWITCHED
OFF AND THE BATTERY IS REMOVED BEFORE
PERFORMING ANY OF THE FOLLOWING TASKS.
a
b
AIR IN
AIR IN
Installing The Battery Pack
The unit will power on once the
battery is inserted. Check that the
operating mode switch is in the ā€˜0ā€™
position.
1. Align the ribs of the battery with
the recess at the front of the unit
and push in until it clicks into
place.
Note: The unit will automatically shut off after 5 minutes of inactivity to
conserve battery life.
2. To remove, press and hold the
battery release tab and pull the
battery away from the tool.
WARNING! DO NOT LEAVE UNATTENDED WHILST
THE TOOL IS IN OPERATION.
WARNING! ENSURE THAT THE INFLATOR IS SITTING
ON A STEADY, LEVEL SURFACE DURING USE.
Adjusting The Pressure Units
While inī˜Ÿating a high pressure item, the
current pressure will be displayed on the
digital display.
Note: When using the inī˜Ÿator to inī˜Ÿate or deī˜Ÿate a high volume item, the
digital display will show ā€œ0.00ā€.
1. Press the pressure mode button to
toggle between the 3 pressure units
(Bar, PSI or kPa).
Presetting The Pressure
When using the high pressure hose, a preset pressure can be set so that the
inī˜Ÿator will automatically shut-off once the desired pressure is reached.
1. Press the pressure mode button
until the desired pressure unit is
displayed on the screen.
2. Increase the preset pressure using the ā€œ+ā€
button or decrease the pressure using the
ā€œ-ā€ button.
The preset pressure will be displayed on
the digital display as it is adjusted.
Manual Inļ¬‚ation
WARNING! MAINTAIN A FIRM HOLD ON THE AIR
HOSE VALVE OR ENSURE THAT THE NOZZLE/VALVE
IS SECURELY ATTACHED, OTHERWISE THE HOSE
MAY BLOW OUT AND WHIP ABOUT.
The manual mode is handy for short bursts of high pressure inī˜Ÿation.
1. Attach the required inī˜Ÿation adaptor to the
high pressure hose and secure using the
locking lever.
2. Insert / attach the hose adaptor to the item to
be inī˜Ÿated.
3. Press and hold down the manual
button in the ā€˜Iā€™ position to start
inī˜Ÿating.
Release the button to stop.
2. FITTING THE BATTERY 3. HIGH PRESSURE CONTROLS
OPERATION
WARNING! ENSURE THE OPERATING MODE SWITCH
IS IN THE OFF POSITION BEFORE INSTALLING THE
BATTERY.
AC
DC
I
0
I
+
MODE
I
a
b
I
0
I
+
I
I
0
+
MODE
I
0
I
+
I
I
0
+
MODE
AC
DC
+
MODE
I
0
+
MODE


Product specificaties

Merk: Ozito
Categorie: Niet gecategoriseerd
Model: PXHDIS-018

Heb je hulp nodig?

Als je hulp nodig hebt met Ozito PXHDIS-018 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Ozito

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd