STANDARD EQUIPMENT
PXGTPS-0182
INSTRUCTION MANUAL
SPECIFICATIONS
Input Power: 18V x 2
Flow Rate Max.: 3000 l/h
Suction Height Max.: 8m
Delivery Height Max.: 26m
Delivery Pressure Max.: 2.6 bar
Water Temperature. 1 C - 35 C° °
Inlet & Outlet: 25mm (1”)
Noise Rating: 76 dB
Weight: 3.3kg
ozito.com.au
0720
Garden Transfer Pump
GARDEN
TRANSFER PUMP
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU
MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS
WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE
OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL
NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER
SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND
ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE
WARRANTY POLICY OR PROCEDURE.
OZITO Australia/New Zealand (Head Ofce) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benets provided under this warranty are in addition to other rights and
remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to
a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this
warranty, however, where you have suffered any additional direct loss as a result of
a defective product you may be able to claim such expenses by contacting our
customer service helpline above.
WARNING
The following actions will result in the warranty being
void.
• If the tool has been operated on a supply voltage other than that specied
on the tool.
• If the tool shows signs of damage or defects caused by or resulting from
abuse, accidents or alterations.
• Failure to perform maintenance as set out within the instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
5 YEAR REPLACEMENT WARRANTY
Your Product is guaranteed for a period of 60 months from the original date of
purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it
will be replaced in accordance with the terms of this warranty. Lithium Ion
batteries and chargers are covered by a 36 month
warranty and are excluded from the warranty extension. Warranty excludes
consumable parts, for example: O-rings, bearings, seals, gaskets .
BATTERY & CHARGER
This tool is compatible with all battery and chargers from the Ozito
Power X Change Range.
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to the
online manual.
1. Battery Cover
2. Carry Handle
3. Pump Setting Switch
4. Discharge Outlet
5. Priming Plug
6. Drain Plug
7. Suction Inlet
CORDLESS GARDEN TRANSFER PUMP
KNOW YOUR PRODUCT
1. INLET & OUTLET
SETUP & PREPARATION
1 2 3 4 5
6 7
WARNING!: ENSURE THE TOOL IS OFF AND THE
BATTERIES ARE REMOVED BEFORE PERFORMING
ANY OF THE FOLLOWING OPERATIONS.
1. Thread seal tape (not included) is
required on threads to ensure a
water tight seal and prevent any
leakage. Wind thread seal tape
clockwise on ttings.
Note: The input hose or pipe you are using must have a minimum diameter
of 25.4mm (1”).
Preparing the Pump: Your pump requires no assembly
before use other than the connection of a suitable inlet/
outlet hose and hose connections (not included).
2. Remove the plastic protection
cover from the suction inlet
and insert a 25.4mm ( 1”)
male threaded hose adaptor
(not included). Tighten rmly
with a spanner (not included).
3. Securely attach the input
hose or pipe to the other
end of the adaptor. Ensure
you have the correct
diameter hose or pipe that is
compatible with your water
drawing source.
WARNING!: ENSURE THE INPUT HOSE OR PIPE
IS NOT RESTRICTED IN ANY WAY.
Connecting Hose or Pipe to the Suction Inlet
Note: A leaking hose or pipe will draw in air and therefore not draw in any
water.
2. INSERTING & REMOVING THE BATTERIES
Connecting Hose or Pipe to the
Discharge Outlet.
1. Thread seal tape (not included) is
required on threads to ensure a water
tight seal and prevent any leakage. Wind
thread seal tape clockwise on ttings.
2. Remove the plastic protection
cover from the discharge
outlet and insert a 25.4mm
(1”) male threaded hose
adaptor (not included).
Tighten rmly with a spanner
(not included).
3. Securely attach the input
hose or pipe to the other
end of the adaptor. Ensure
you have the correct
diameter hose or pipe that is
compatible with your water
discharge application.
WARNING!: ENSURE THE DISCHARGE HOSE
OR PIPE IS NOT RESTRICTED IN ANY WAY AND
NOTHING IS OBSTRUCTING THE HOSE OR PIPE
WHEN THE PUMP IS IN OPERATION.
Note: The discharge hose or pipe you are using must have a minimum
diameter of 13mm (1/2”).
WARNING!: RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-
PROOF OR IF THEY ARE IMPROPERLY INSTALLED,
THE PRESSURE LINE COULD BURST DURING
OPERATION.
Inserting the Batteries
Always use 2 batteries of the same capacity and
charge state with the garden transfer pump.
1. Slide two batteries of the same capacity and same charge state into the
battery mount aligning the ribs so that they click into place.
Note: For best performance use only batteries which are charged to the
same level. Never combine full and half-full batteries as the equipment‘s
operating time depends on the battery with the lower charge level.
Removing the Batteries
1. Press and hold the battery release tab to release a battery and slide the
battery out.
PRESS
Product specificaties
Merk: | Ozito |
Categorie: | Pomp |
Model: | PXGTPS-0182 |
Heb je hulp nodig?
Als je hulp nodig hebt met Ozito PXGTPS-0182 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Ozito
12 Juni 2023
31 Mei 2023
21 Mei 2023
29 April 2023
25 April 2023
8 April 2023
2 April 2023
28 Maart 2023
15 Maart 2023
25 Februari 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
4 December 2024
4 December 2024
30 November 2024
30 November 2024
23 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
18 November 2024